AIM: To assess the efficacy of automated "disease/no disease" grading for diabetic retinopathy within a systematic screening programme. METHODS: Anonymised images were obtained from consecutive patients attending a regional primary care based diabetic retinopathy screening programme. A training set of 1067 images was used to develop automated grading algorithms. The final software was tested using a separate set of 14 406 images from 6722 patients. The sensitivity and specificity of manual and automated systems operating as "disease/no disease" graders (detecting poor quality images and any diabetic retinopathy) were determined relative to a clinical reference standard. RESULTS: The reference standard classified 8.2% of the patients as having ungradeable images (technical failures) and 62.5% as having no retinopathy. Detection of technical failures or any retinopathy was achieved by manual grading with 86.5% sensitivity (95% confidence interval 85.1 to 87.8) and 95.3% specificity (94.6 to 95.9) and by automated grading with 90.5% sensitivity (89.3 to 91.6) and 67.4% specificity (66.0 to 68.8). Manual and automated grading detected 99.1% and 97.9%, respectively, of patients with referable or observable retinopathy/maculopathy. Manual and automated grading detected 95.7% and 99.8%, respectively, of technical failures. CONCLUSION: Automated "disease/no disease" grading of diabetic retinopathy could safely reduce the burden of grading in diabetic retinopathy screening programmes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Convolutional Neural Networks for Diabetic Retinopathy
Pratt, H., Coenen, F., Broadbent, D. M., Harding, S. P., & Zheng, Y. (2016) · Procedia Computer Science · doi:10.1016/j.procs.2016.07.014 · Cited by 988
Digital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy
Abràmoff, M. D., Folk, J. C., Han, D. P., Walker, J. D., Williams, D. F., Russell, S. R., Massin, P., Cochener, B., Gain, P., Tang, L., et al. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.1743 · Cited by 463
Computer-aided diagnosis of diabetic retinopathy: A review
Mookiah, M. R. K., Acharya, U. R., Chua, C. K., Lim, C. M., Ng, E. Y. K., & Laude, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.007 · Cited by 430
Exudate-based diabetic macular edema detection in fundus images using publicly available datasets
Giancardo, L., Meriaudeau, F., Karnowski, T. P., Li, Y., Garg, S., Tobin, K. W., & Chaum, E. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.07.004 · Cited by 322
Algorithms for the Automated Detection of Diabetic Retinopathy Using Digital Fundus Images: A Review
Faust, O., Acharya U., R., Ng, E. Y. K., Ng, K.-H., & Suri, J. S. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9454-7 · Cited by 303
van der Heijden, A. A., Abramoff, M. D., Verbraak, F., van Hecke, M. V., Liem, A., & Nijpels, G. (2018) · Acta Ophthalmologica · doi:10.1111/aos.13613 · Cited by 296
“The sensitivity of the IDx-DR device based on EURODIAB was comparable to the other algorithms while specificity of the IDx-DR device was similar or higher compared to these algorithms (Hansen et al. 2004; Philip et al. 2007; Oliveira et al. 2011).”
Automated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Automated Diabetic Retinopathy Image Assessment Software
Tufail, A., Rudisill, C., Egan, C., Kapetanakis, V. V., Salas-Vega, S., Owen, C. G., Lee, A., Louw, V., Anderson, J., Liew, G., et al. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.11.014 · Cited by 283
Abràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B. (2008) · Diabetes Care · doi:10.2337/dc07-1312 · Cited by 277
Multiscale AM-FM Methods for Diabetic Retinopathy Lesion Detection
Agurto, C., Murray, V., Barriga, E., Murillo, S., Pattichis, M., Davis, H., Russell, S., Abramoff, M., & Soliz, P. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2037146 · Cited by 259
An ensemble-based system for automatic screening of diabetic retinopathy
Antal, B., & Hajdu, A. (2014) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.12.023 · Cited by 256
Artificial intelligence promotes the diagnosis and screening of diabetic retinopathy
Huang, X., Wang, H., She, C., Feng, J., Liu, X., Hu, X., Chen, L., & Tao, Y. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.946915 · Cited by 115
Contemporary retinal imaging techniques in diabetic retinopathy: a review
Cole, E. D., Novais, E. A., Louzada, R. N., & Waheed, N. K. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12711 · Cited by 91
Xie, Y., Gunasekeran, D. V., Balaskas, K., Keane, P. A., Sim, D. A., Bachmann, L. M., Macrae, C., & Ting, D. S. W. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.22 · Cited by 59
Metadata
- Authors
- Philip, S., Fleming, A. D., Goatman, K. A., Fonseca, S., Mcnamee, P., Scotland, G. S., Prescott, G. J., Sharp, P. F., & Olson, J. A.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2007-05-15
- Volume
- 91
- Issue
- 11
- Pages
- 1512-1517
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2062393305
- Cited by
- 225
- References
- 0
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.