The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Automatic detection of diabetic retinopathy using an artificial neural network: a screening tool.
Open accessAbstract
AIMS: To determine if neural networks can detect diabetic features in fundus images and compare the network against an ophthalmologist screening a set of fundus images. METHODS: 147 diabetic and 32 normal images were captured from a fundus camera, stored on computer, and analysed using a back propagation neural network. The network was trained to recognise features in the retinal image. The effects of digital filtering techniques and different network variables were assessed. 200 diabetic and 101 normal images were then randomised and used to evaluate the network's performance for the detection of diabetic retinopathy against an ophthalmologist. RESULTS: Detection rates for the recognition of vessels, exudates, and haemorrhages were 91.7%, 93.1%, and 73.8% respectively. When compared with the results of the ophthalmologist, the network achieved a sensitivity of 88.4% and a specificity of 83.5% for the detection of diabetic retinopathy. CONCLUSIONS: Detection of vessels, exudates, and haemorrhages was possible, with success rates dependent upon preprocessing and the number of images used in training. When compared with the ophthalmologist, the network achieved good accuracy for the detection of diabetic retinopathy. The system could be used as an aid to the screening of diabetic patients for retinopathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, Y., Giger, M. L., Doi, K., Vyborny, C. J., Schmidt, R. A., & Metz, C. E. (1993) · Radiology · doi:10.1148/radiology.187.1.8451441 · Cited by 421
Screening for Diabetic Retinopathy
Singer, D. E., Nathan, D. M., Fogel, H. A., & Schachat, A. P. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-116-8-660 · Cited by 292
Cost Effectiveness of Current Approaches to the Control of Retinopathy in Type I Diabetics
Javitt, J. C., Canner, J. K., & Sommer, A. (1989) · Ophthalmology · doi:10.1016/s0161-6420(89)32923-x · Cited by 177
Screening for Diabetic Retinopathy: The wide-angle retinal camera
Pugh, J. A., Jacobson, J. M., Van Heuven, W. A. J., Watters, J. A., Tuley, M. R., Lairson, D. R., Lorimor, R. J., Kapadia, A. S., & Velez, R. (1993) · Diabetes Care · doi:10.2337/diacare.16.6.889 · Cited by 172
Taylor, R. M., Lovelock, L., Tunbridge, W. M. G., Alberti, K. G. M. M., Brackenridge, R. G., Stephenson, P. D., & Young, E. (1990) · BMJ · doi:10.1136/bmj.301.6763.1243 · Cited by 126
A Protocol for Screening for Diabetic Retinopathy in Europe
Party, R. W. (1991) · Diabetic Medicine · doi:10.1111/j.1464-5491.1991.tb01583.x · Cited by 113
Interpretation of automated perimetry for glaucoma by neural network.
Goldbaum, M. H., Sample, P. A., White, H., Côlt, B., Raphaelian, P., Fechtner, R. D., & Weinreb, R. N. (1994) · PubMed · Cited by 111
Assessment of non-mydriatic fundus photography in detection of diabetic retinopathy.
Williams, R., Nussey, S., Humphry, R. C., & Thompson, G. M. (1986) · BMJ · doi:10.1136/bmj.293.6555.1140 · Cited by 99
The application of backpropagation neural networks to problems in pathology and laboratory medicine.
Astion, M. L., & Wilding, P. M. (1992) · PubMed · Cited by 98
Shih-Chung, B. L., Freedman, M. T., Lin, J.-S., & Mun, S. K. (1993) · Journal of Digital Imaging · doi:10.1007/bf03168418 · Cited by 94
Ryder, R. E. J., Vora, J. P., Atiea, J., Owens, D. R., Hayes, T. M., & Young, S. (1985) · BMJ · doi:10.1136/bmj.291.6504.1256 · Cited by 61
Comparison of Diabetic Retinopathy Detection by Clinical Examinations and Photograph Gradings
SCHACHAT, A. P. (1993) · Archives of Ophthalmology · doi:10.1001/archopht.1993.01090080060019 · Cited by 51
Cited by
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Convolutional Neural Networks for Diabetic Retinopathy
Pratt, H., Coenen, F., Broadbent, D. M., Harding, S. P., & Zheng, Y. (2016) · Procedia Computer Science · doi:10.1016/j.procs.2016.07.014 · Cited by 988
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Metadata
- Authors
- Gardner, G. G., Keating, D., Williamson, T. H., & Elliott, A. T.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 1996-11-01
- Volume
- 80
- Issue
- 11
- Pages
- 940-944
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W1989786678
- Cited by
- 508
- References
- 12
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.