Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its Crossref record.

Comparison of two reference standards in validating two field mydriatic digital photography as a method of screening for diabetic retinopathy

Open access
Scanlon, P H · 2003 · British Journal of Ophthalmology

Abstract

AIM: To compare two reference standards when evaluating a method of screening for referable diabetic retinopathy. METHOD: Clinics at Oxford and Norwich Hospitals were used in a two centre prospective study of 239 people with diabetes receiving an ophthalmologist's examination using slit lamp biomicroscopy, seven field 35 mm stereophotography and two field mydriatic digital photography. Patients were selected from those attending clinics when the ophthalmologist and ophthalmic photographer were able to attend. The main outcome measures were the detection of referable diabetic retinopathy as defined by the Gloucestershire adaptation of the European Working Party guidelines. RESULTS: In comparison with seven field stereophotography, the ophthalmologist's examination gave a sensitivity of 87.4% (confidence interval 83.5 to 91.5), a specificity of 94.9% (91.5 to 98.3), and a kappa statistic of 0.80. Two field mydriatic digital photography gave a sensitivity of 80.2% (75.2 to 85.2), specificity of 96.2% (93.2 to 99.2), and a kappa statistic of 0.73. In comparison with the ophthalmologist's examination, two field mydriatic digital photography gave a sensitivity of 82.8% (78.0 to 87.6), specificity of 92.9% (89.6 to 96.2), and a kappa statistic of 0.76. Seven field stereo gave a sensitivity of 96.4% (94.0 to 98.8), a specificity of 82.9% (77.4 to 88.4), and a kappa statistic of 0.80. 15.3% of seven field sets, 1.5% of the two field digital photographs, and none of the ophthalmologist's examinations were ungradeable. CONCLUSION: An ophthalmologist's examination compares favourably with seven field stereophotography, and two field digital photography performs well against both reference standards.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjo.87.10.1258

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Scanlon, P. H.
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2003-10-01
Volume
87
Issue
10
Pages
1258-1263
ISSN
0007-1161 (ISSN-L)
OpenAlex
W2109421862
Cited by
158
References
0
FWCI
3.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of two reference standards in validating two field mydriatic digital photography as a method of screening for diabetic retinopathy. https://app.cochat.ai/papers/10.1136/bjo.87.10.1258
The paper
Scanlon, P. H. (2003). Comparison of two reference standards in validating two field mydriatic digital photography as a method of screening for diabetic retinopathy. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.87.10.1258

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.