The DOI matches its Crossref record.
Comparison of two reference standards in validating two field mydriatic digital photography as a method of screening for diabetic retinopathy
Open accessAbstract
AIM: To compare two reference standards when evaluating a method of screening for referable diabetic retinopathy. METHOD: Clinics at Oxford and Norwich Hospitals were used in a two centre prospective study of 239 people with diabetes receiving an ophthalmologist's examination using slit lamp biomicroscopy, seven field 35 mm stereophotography and two field mydriatic digital photography. Patients were selected from those attending clinics when the ophthalmologist and ophthalmic photographer were able to attend. The main outcome measures were the detection of referable diabetic retinopathy as defined by the Gloucestershire adaptation of the European Working Party guidelines. RESULTS: In comparison with seven field stereophotography, the ophthalmologist's examination gave a sensitivity of 87.4% (confidence interval 83.5 to 91.5), a specificity of 94.9% (91.5 to 98.3), and a kappa statistic of 0.80. Two field mydriatic digital photography gave a sensitivity of 80.2% (75.2 to 85.2), specificity of 96.2% (93.2 to 99.2), and a kappa statistic of 0.73. In comparison with the ophthalmologist's examination, two field mydriatic digital photography gave a sensitivity of 82.8% (78.0 to 87.6), specificity of 92.9% (89.6 to 96.2), and a kappa statistic of 0.76. Seven field stereo gave a sensitivity of 96.4% (94.0 to 98.8), a specificity of 82.9% (77.4 to 88.4), and a kappa statistic of 0.80. 15.3% of seven field sets, 1.5% of the two field digital photographs, and none of the ophthalmologist's examinations were ungradeable. CONCLUSION: An ophthalmologist's examination compares favourably with seven field stereophotography, and two field digital photography performs well against both reference standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Ting, D. S. W., Cheung, G. C. M., & Wong, T. Y. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12696 · Cited by 1,066
Screening for diabetic retinopathy: new perspectives and challenges
Vujosevic, S., Aldington, S. J., Silva, P., Hernández, C., Scanlon, P., Peto, T., & Simó, R. (2020) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(19)30411-5 · Cited by 671
Self-citationA deep learning system for detecting diabetic retinopathy across the disease spectrum
Dai, L., Wu, L., Li, H., Cai, C., Wu, Q., Kong, H., Liu, R., Wang, X., Hou, X., Liu, Y., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23458-5 · Cited by 620
The English National Screening Programme for diabetic retinopathy 2003–2016
Scanlon, P. H. (2017) · Acta Diabetologica · doi:10.1007/s00592-017-0974-1 · Cited by 440
Self-citationValidation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening
Rajalakshmi, R., Arulmalar, S., Usha, M., Prathiba, V., Kareemuddin, K. S., Anjana, R. M., & Mohan, V. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138285 · Cited by 173
Artificial Intelligence Detection of Diabetic Retinopathy
Lim, J. I., Regillo, C. D., Sadda, S. R., Ipp, E., Bhaskaranand, M., Ramachandra, C., Solanki, K., Dubiner, H., Levy-Clarke, G., Pesavento, R., et al. (2023) · Ophthalmology Science · doi:10.1016/j.xops.2022.100228 · Cited by 157
“Scanlon et al 11 explain that the difference in referable retinopathy detection between ophthalmoscopy and 7-fi eld stereopho-tography was primarily because of dif fi culty in distinguishing hemorrhages and microaneurysms.”
Diabetic retinopathy management guidelines
Chakrabarti, R., Harper, C. A., & Keeffe, J. E. (2012) · Expert Review of Ophthalmology · doi:10.1586/eop.12.52 · Cited by 112
Piyasena, M. M. P. N., Yip, J. L. Y., MacLeod, D., Kim, M., & Gudlavalleti, V. S. M. (2019) · BMC Ophthalmology · doi:10.1186/s12886-019-1092-3 · Cited by 70
Automated and computer-assisted detection, classification, and diagnosis of diabetic retinopathy
Abràmoff, M. D., Leng, T., Ting, D. S. W., Rhee, K., Horton, M. B., Brady, C. J., & Chiang, M. F. (2020) · Telemedicine and e-Health · doi:10.1089/tmj.2020.0008 · Cited by 30
Conlin, P. R., Asefzadeh, B., Pasquale, L. R., Selvin, G., Lamkin, R., & Cavallerano, A. A. (2015) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-306536 · Cited by 20
Metadata
- Authors
- Scanlon, P. H.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2003-10-01
- Volume
- 87
- Issue
- 10
- Pages
- 1258-1263
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2109421862
- Cited by
- 158
- References
- 0
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.