Accuracy of a technology-assisted eye exam in evaluation of referable diabetic retinopathy and concomitant ocular diseases
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
BACKGROUND/AIMS: Digital retinal imaging using store-and-forward technology is used to screen for diabetic retinopathy (DR). Its usefulness in detecting non-diabetic eye diseases is uncertain. We determined the level of agreement between teleretinal imaging supplemented with visual acuity and intraocular pressure (IOP) measurements (ie, technology-assisted eye (TAE) exam) and a comprehensive eye exam in evaluation for DR and non-diabetic ocular conditions. METHODS: We conducted a prospective, observational study with two parallel evaluations. Patients with diabetes (n=317) had a TAE exam and a comprehensive eye exam on the same day. A subset of participants with normal baseline exams (n=72) had follow-up exams 1 year later. We measured the level of agreement for referable ocular findings. RESULTS: Agreement for referable ocular findings was moderate (n=389, agreement: 77%; κ: 0.55), due in part to ungradable exams (22%). However, about half of the ungradable exams had findings that warranted referral. There was substantial agreement for follow-up exams (n=72, agreement: 93%; κ: 0.63). Among all gradable exams (n=303), the TAE exam had 86% sensitivity and 84% specificity for referable ocular findings, with high agreement (≥94%) for DR and other major ocular diagnoses. CONCLUSIONS: There was moderate-to-substantial agreement between a TAE exam and a comprehensive eye exam for referable ocular findings in patients with diabetes. Ungradable exams were a frequent marker of ocular pathology. Teleretinal imaging may be a useful evaluation for both diabetic and non-diabetic ocular conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Artificial intelligence approaches to screening for diabetic retinopathy have progressed to the point of utility and cost-effectiveness.508–513”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [509]
Citations
Cites
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Cost-Effectiveness of Detecting and Treating Diabetic Retinopathy
Javitt, J. C., & Aiello, L. P. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_2-199601011-00017 · Cited by 411
Harding, S. P., Broadbent, D. M., Neoh, C., White, M. C., & Vora, J. (1995) · BMJ · doi:10.1136/bmj.311.7013.1131 · Cited by 295
Patterns of adherence to diabetes vision care guidelines
Schoenfeld, E. R., Greene, J. M., Wu, S. Y., & Leske, M. C. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00600-x · Cited by 253
Bursell, S.-E., Cavallerano, J. D., Cavallerano, A. A., Clermont, A. C., Birkmire-Peters, D., Aiello, L. P., & Aiello, L. M. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00604-7 · Cited by 246
Self-citationScanlon, P. H. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.10.1258 · Cited by 158
Kırkızlar, E., Serban, N., Sisson, J. A., Swann, J., Barnes, C. S., & Williams, M. D. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.06.029 · Cited by 154
Ahmed, J., Ward, T. P., Bursell, S.-E., Aiello, L. M., Cavallerano, J. D., & Vigersky, R. A. (2006) · Diabetes Care · doi:10.2337/dc06-0295 · Cited by 152
Digital Retinal Images and Teleophthalmology for Detecting and Grading Diabetic Retinopathy
Gómez-Ulla, F., Fernandez, M. I., Gonzalez, F., Rey, P., Rodriguez, M., Rodriguez-Cid, M. J., Casanueva, F. F., Tome, M. A., Garcia-Tobio, J., & Gude, F. (2002) · Diabetes Care · doi:10.2337/diacare.25.8.1384 · Cited by 133
Whited, J. D., Datta, S. K., Aiello, L. M., Aiello, L. P., Cavallerano, J. D., Conlin, P. R., Horton, M. B., Vigersky, R. A., Poropatich, R. K., Challa, P., et al. (2005) · Telemedicine and e-Health · doi:10.1089/tmj.2005.11.641 · Cited by 116
Self-citationAgardh, E., & Tababat-Khani, P. (2011) · Diabetes Care · doi:10.2337/dc10-2308 · Cited by 113
Barriers to compliance with screening guidelines for diabetic retinopathy
Mukamel, B. D., Bresnick, H. G., Wang, Q., & Dickey, F. C. (1999) · Ophthalmic Epidemiology · doi:10.1076/opep.6.1.61.1563 · Cited by 111
CAVALLERANO, A. A., Cavallerano, J. D., Katalinic, P., Blake, B., Rynne, M., Conlin, P. R., Hock, K. M., Tolson, A. M., Aiello, L. P., & Aiello, L. M. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.10.064 · Cited by 97
Self-citationCAVALLERANO, A. A., CAVALLERANO, J. D., KATALINIC, P., TOLSON, A. M., AIELLO, L. P., & AIELLO, L. M. (2003) · RETINA · doi:10.1097/00006982-200304000-00013 · Cited by 94
Self-citationEffect of a Teleretinal Screening Program on Eye Care Use and Resources
Chasan, J. E., Delaune, B., Maa, A. Y., & Lynch, M. G. (2014) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.1051 · Cited by 83
Conlin, P. R., Fisch, B. M., Cavallerano, A. A., Cavallerano, J. D., Bursell, S.-E., & Aiello, L. M. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.07.0117 · Cited by 82
Self-citationPreventing and Managing Visual Disability in Primary Care
Goldzweig, C. L., Rowe, S. G., Wenger, N. S., MacLean, C. H., & Shekelle, P. (2004) · JAMA · doi:10.1001/jama.291.12.1497 · Cited by 58
Ocular Telehealth Screenings in an Urban Community
Shahid, K., Kolomeyer, A. M., Nayak, N. V., Salameh, N., Pelaez, G., Khouri, A. S., Eck, T. T., & Szirth, B. (2012) · Telemedicine and e-Health · doi:10.1089/tmj.2011.0067 · Cited by 48
Romero‐Aroca, P., Sagarra-Alamo, R., Ferrer, J., Fernandez-Ballart, J. D., & Baget, M. (2010) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2010.02.001 · Cited by 44
A Novel Tele-Eye Protocol for Ocular Disease Detection and Access to Eye Care Services
Maa, A. Y., Evans, C., DeLaune, W. R., Patel, P. S., & Lynch, M. G. (2014) · Telemedicine and e-Health · doi:10.1089/tmj.2013.0185 · Cited by 40
IDRIS, I. R., Sellahewa, L., Simpson, C., Maharajan, P., & Duffy, J. (2014) · Clinical ophthalmology · doi:10.2147/opth.s61483 · Cited by 28
From Humble Beginnings—Two Decades of Success
Doarn, C. R., & Merrell, R. C. (2013) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2014.9998 · Cited by 14
Healy, R., Sallam, A. B., Jones, V., Donachie, P. H. J., Scanlon, P. H., STRATTON, I. M., & Johnston, R. L. (2013) · European Journal of Ophthalmology · doi:10.5301/ejo.5000404 · Cited by 7
Cited by
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Real-time teleophthalmology versus face-to-face consultation: A systematic review
Tan, I. J., Dobson, L. P., Bartnik, S. E., Muir, J., & Turner, A. W. (2016) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x16660640 · Cited by 75
Pieczynski, J., Kuklo, P., & Grzybowski, A. (2021) · Ophthalmology and Therapy · doi:10.1007/s40123-021-00353-2 · Cited by 54
Diagnostic Accuracy of Technology-based Eye Care Services
Maa, A. Y., Medert, C. M., Lu, X., Janjua, R., Howell, A. V., Hunt, K. J., McCord, S., Giangiacomo, A., & Lynch, M. G. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.07.026 · Cited by 53
Effectiveness of a telemedicine program for triage and diagnosis of emergent ophthalmic conditions
Meshkin, R. S., Armstrong, G. W., Hall, N. E., Rossin, E. J., Hymowitz, M. B., & Lorch, A. (2022) · Eye · doi:10.1038/s41433-022-01940-8 · Cited by 38
“Expected sensitivity and specificity were based on two previous studies; one of referable diabetic retinopathy and concomitant ocular diseases, which achieved 90% sensitivity and 69% specificity for diagnosis [23]; and another study using smartphone technology in an emergency room reporting 92.”
Metadata
- Authors
- Conlin, P. R., Asefzadeh, B., Pasquale, L. R., Selvin, G., Lamkin, R., & Cavallerano, A. A.
- Affiliations
- Harvard University (US)
- New England College of Optometry (US)
- Brigham and Women's Hospital (US)
- VA Boston Healthcare System (US)
- Corresponding author
- Asefzadeh, Baharak
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2015-05-20
- Volume
- 99
- Issue
- 12
- Pages
- 1622-1627
- ISSN
- 0007-1161 (ISSN-L)
- 1468-2079
- OpenAlex
- W1868732297
- Cited by
- 20
- References
- 24
- Citations by year
- 2024: 2 · 2023: 2 · 2022: 4 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 1
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- British Journal of Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (K24DK063214, K24DK63214)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Keywords
- diabetic retinopathy, store-and-forward telemedicine, intraocular pressure, visual acuity, diagnostic agreement
- MeSH terms
- Aged, Aged, 80 and over, Diabetic Retinopathy, Eye Diseases, False Positive Reactions, Female, Humans, Male, Middle Aged, Photography, Physical Examination, Predictive Value of Tests, Prospective Studies, Referral and Consultation, Sensitivity and Specificity, Visual Acuity, Reproducibility of Results, Telemedicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.