CoChat

Polar Activity Watch 200: a new device to accurately assess energy expenditure

Brugniaux, J V, Niva, A, Pulkkinen, I, Laukkanen, R M T, Richalet, J-P, Pichon, A P · 2010 · British Journal of Sports Medicine
Cited by 54

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Objectives: Energy expenditure (EE) based on movement detection is calculated by a new device, the Activity Watch 200 (AW200). The aim of this study was to validate EE measured by this device against indirect calorimetry (IC) and to assess the reproducibility of AW200 measurements. Design: EE was assessed during a 9.7 km hike. 10 men and 10 women in the age range 35–45 years, and 5 men and 6 women in the age range 50–55 years were tested. One in five participants of each age- and sex-matched group was equipped with a portable metabograph (Oxycon Mobil) for IC measurements. Data were collected every 30 min during the hike, and IC was extrapolated for the remaining four other participants of the group. Results: During the total hike, there was a high correlation between EE obtained from the AW200 and the IC calculation (r = 0.987, p<0.001). Identical values of EE were calculated by both methods during the first 90 min of the hike. However, EE calculated by the AW200 at 120 min and at the end of the hike was lower (p<0.05). Bland–Altman analysis showed limits of agreements between 105 and 279 kJ after 30 and 120 min, respectively. EE measured by the AW200 was well correlated with IC measurements, and limits of agreement between devices were below 10% of the measured values for hike durations longer than 60 min. Conclusion: The AW200 appears to be a very useful and accurate device for measuring EE during exercise in recreational hikers and provides a useful tool for keeping track of personal EE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjsm.2007.045575

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 54

Metadata

Authors
Brugniaux, J. V., Niva, A., Pulkkinen, I., Laukkanen, R. M. T., Richalet, J.-P., & Pichon, A. P.
Venue
British Journal of Sports Medicine
Publisher
BMJ
Published
2008-04-15
Volume
44
Issue
4
Pages
245-249
ISSN
  • 0306-3674 (ISSN-L)
  • 1473-0480
OpenAlex
W2152091049
Cited by
54
References
9
FWCI
1.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Polar Activity Watch 200: a new device to accurately assess energy expenditure. https://app.cochat.ai/papers/10.1136/bjsm.2007.045575
The paper
Brugniaux, J. V., Niva, A., Pulkkinen, I., Laukkanen, R. M. T., Richalet, J.-P., & Pichon, A. P. (2010). Polar Activity Watch 200: a new device to accurately assess energy expenditure. British Journal of Sports Medicine. https://doi.org/10.1136/bjsm.2007.045575

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.