Objective: To determine the accuracy of wrist and arm-worn activity monitors’ estimates of energy expenditure (EE). Data sources: SportDISCUS (EBSCOHost), PubMed, MEDLINE (Ovid), PsycINFO (EBSCOHost), Embase (Ovid) and CINAHL (EBSCOHost). Design: A random effects meta-analysis was performed to evaluate the difference in EE estimates between activity monitors and criterion measurements. Moderator analyses were conducted to determine the benefit of additional sensors and to compare the accuracy of devices used for research purposes with commercially available devices. Eligibility criteria: We included studies validating EE estimates from wrist-worn or arm-worn activity monitors against criterion measures (indirect calorimetry, room calorimeters and doubly labelled water) in healthy adult populations. Results: 60 studies (104 effect sizes) were included in the meta-analysis. Devices showed variable accuracy depending on activity type. Large and significant heterogeneity was observed for many devices (I 2 >75%). Combining heart rate or heat sensing technology with accelerometry decreased the error in most activity types. Research-grade devices were statistically more accurate for comparisons of total EE but less accurate than commercial devices during ambulatory activity and sedentary tasks. Conclusions: EE estimates from wrist and arm-worn devices differ in accuracy depending on activity type. Addition of physiological sensors improves estimates of EE, and research-grade devices are superior for total EE. These data highlight the need to improve estimates of EE from wearable devices, and one way this can be achieved is with the addition of heart rate to accelerometry. PROSPEROregistration number: CRD42018085016.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjsports-2018-099643

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Research works printed but not linked: 78

  1. 10.1136/bmj.k7 · DOI
  2. Agha, 2017, The rising prevalence of obesity, Int J Surg Oncol, 2, e17, 10.1097/IJ9.0000000000000017 · DOI · Paper page
  3. 10.3945/an.115.008755 · DOI · Paper page
  4. 10.1063/1.354123 · doi:10.1063/1.354123
  5. DeLany, 2012, Measurement of energy expenditure, Pediatr Blood Cancer, 58, 129, 10.1002/pbc.23369 · DOI
  6. Hills, 2014, Assessment of physical activity and energy expenditure: an overview of objective measures, Front Nutr, 1, 1, 10.3389/fnut.2014.00005 · DOI · Paper page
  7. 10.1089/152091503322641088 · DOI
  8. Diaz, 2016, Validation of the Fitbit One® for physical activity measurement at an upper torso attachment site, BMC Res Notes, 9, 213, 10.1186/s13104-016-2020-8 · DOI · Paper page
  9. 10.1038/ejcn.2014.51 · DOI
  10. 10.3389/fphys.2017.00788 · DOI · Paper page
  11. 10.1001/jama.2017.19163 · DOI · Paper page
  12. Nelson, 2016, Validity of consumer-based physical activity monitors for specific activity types, Med Sci Sports Exerc, 48, 1619, 10.1249/MSS.0000000000000933 · DOI · Paper page
  13. 10.1186/1479-5868-9-84 · DOI · Paper page
  14. 10.1161/JAHA.116.003231 · DOI · Paper page
  15. Cohen J . Statistical power analysis for the behavioral sciences. Massachusetts: Academic Press, 1977.
  16. 10.1002/sim.1186 · DOI · Paper page
  17. 10.1136/bmj.315.7109.629 · DOI · Paper page
  18. Lopez, 2018, Validation of sensewear armband in children, adolescents, and adults, Scand J Med Sci Sports, 28, 487, 10.1111/sms.12920 · doi:10.1111/sms.12920
  19. Reeve, 2014, Accuracy of the sensewear armband mini and the bodymedia FIT in resistance training, J Sci Med Sport, 17, 630, 10.1016/j.jsams.2013.08.007 · DOI
  20. Machač, 2013, Validation of physical activity monitors in individuals with diabetes: energy expenditure estimation by the multisensor sensewear armband Pro3 and the step counter Omron HJ-720 against indirect calorimetry during walking, Diabetes Technol Ther, 15, 413, 10.1089/dia.2012.0235 · DOI
  21. Alsubheen, 2016, Accuracy of the vivofit activity tracker, J Med Eng Technol, 40, 298, 10.1080/03091902.2016.1193238 · DOI
  22. Bai, 2018, Comparative evaluation of heart rate-based monitors: apple watch vs fitbit charge HR, J Sports Sci, 36, 1734, 10.1080/02640414.2017.1412235 · DOI
  23. Benito, 2012, Validation of the sensewear armband in circuit resistance training with different loads, Eur J Appl Physiol, 112, 3155, 10.1007/s00421-011-2269-5 · DOI
  24. 10.1136/bjsm.2008.048868 · DOI · Paper page
  25. 10.1111/j.1600-0412.2011.01172.x · DOI
  26. Bhammar, 2016, Validity of sensewear® Armband v5.2 and v2.2 for estimating energy expenditure, J Sports Sci, 34, 1830, 10.1080/02640414.2016.1140220 · DOI
  27. Brazeau, 2011, Accuracy of the SenseWear Armband™ during ergocycling, Int J Sports Med, 32, 761, 10.1055/s-0031-1279768 · doi:10.1055/s-0031-1279768
  28. Brazeau, 2014, Accuracy of energy expenditure estimation by activity monitors differs with ethnicity, Int J Sports Med, 35, 847, 10.1055/s-0034-1371837 · doi:10.1055/s-0034-1371837
  29. 10.1016/j.jsams.2014.11.001 · DOI
  30. 10.1136/bjsm.2007.045575 · DOI
  31. 10.1186/s12966-014-0119-7 · DOI
  32. 10.1038/ejcn.2014.241 · DOI
  33. Casiraghi, 2013, Energy expenditure evaluation in humans and non-human primates by sensewear armband. Validation of energy expenditure evaluation by SenseWear Armband by direct comparison with indirect calorimetry, PLoS One, 8, 10.1371/journal.pone.0073651 · DOI
  34. 10.1249/MSS.0b013e3181fc7162 · DOI · Paper page
  35. Correa, 2016, Evaluation of the ability of three physical activity monitors to predict weight change and estimate energy expenditure, Appl Physiol Nutr Metab, 41, 758, 10.1139/apnm-2015-0461 · DOI
  36. Dondzila, 2016, Comparative accuracy of fitness tracking modalities in quantifying energy expenditure, J Med Eng Technol, 40, 325, 10.1080/03091902.2016.1197978 · DOI
  37. Erdogan, 2010, Accuracy of the polar S810i(TM) heart rate monitor and the sensewear pro armband(TM) to estimate energy expenditure of indoor rowing exercise in overweight and obese individuals, J Sports Sci Med, 9, 508
  38. 10.1249/01.MSS.0000128144.91337.38 · DOI · Paper page
  39. Gastin, 2018, Validity of the ActiGraph GT3X+ and BodyMedia SenseWear Armband to estimate energy expenditure during physical activity and sport, J Sci Med Sport, 21, 291, 10.1016/j.jsams.2017.07.022 · DOI
  40. Heiermann, 2011, Accuracy of a portable multisensor body monitor for predicting resting energy expenditure in older people: a comparison with indirect calorimetry, Gerontology, 57, 473, 10.1159/000322109 · DOI
  41. Imboden, 2018, Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure, Br J Sports Med, 52, bjsports-2016-096990, 10.1136/bjsports-2016-096990 · DOI
  42. Jakicic, 2004, Evaluation of the sensewear pro armband to assess energy expenditure during exercise, Med Sci Sports Exerc, 36, 897, 10.1249/01.MSS.0000126805.32659.43 · DOI · Paper page
  43. 10.1249/MSS.0b013e3181e0b3ff · DOI · Paper page
  44. Kim, 2015, Criterion validity of competing accelerometry-based activity monitoring devices, Med Sci Sports Exerc, 47, 2456, 10.1249/MSS.0000000000000691 · DOI
  45. 10.1249/01.MSS.0000132379.09364.F8 · DOI · Paper page
  46. Koehler, 2011, Assessing energy expenditure in male endurance athletes: validity of the sensewear armband, Med Sci Sports Exerc, 43, 1328, 10.1249/MSS.0b013e31820750f5 · DOI
  47. Lee, 2011, Accuracy of an infrared LED device to measure heart rate and energy expenditure during rest and exercise, J Sports Sci, 29, 1645, 10.1080/02640414.2011.609899 · DOI
  48. 10.1093/gerona/glr101. · DOI
  49. Martien, 2015, Energy expenditure in institutionalized older adults: validation of sensewear mini, Med Sci Sports Exerc, 47, 1265, 10.1249/MSS.0000000000000529 · DOI
  50. 10.1016/j.ypmed.2012.02.013 · DOI
  51. Melanson, 2009, A novel approach for measuring energy expenditure in free-living humans, Conf Proc IEEE Eng Med Biol Soc, 2009, 6873
  52. Montoye, 2017, Comparative accuracy of a wrist-worn activity tracker and a smart shirt for physical activity assessment, Meas Phys Educ Exerc Sci, 21, 201, 10.1080/1091367X.2017.1331166 · DOI
  53. Murakami, 2016, Accuracy of wearable devices for estimating total energy expenditure, JAMA Intern Med, 176, 702, 10.1001/jamainternmed.2016.0152 · DOI · Paper page
  54. Papazoglou, 2006, Evaluation of a multisensor armband in estimating energy expenditure in obese individuals, Obesity, 14, 2217, 10.1038/oby.2006.260 · DOI
  55. Price, 2017, Validation of the fitbit one, garmin vivofit and jawbone UP activity tracker in estimation of energy expenditure during treadmill walking and running, J Med Eng Technol, 41, 208, 10.1080/03091902.2016.1253795 · DOI
  56. Reece, 2015, Validation of the sensewear armband as a measure of sedentary behavior and light Activity, J Phys Act Health, 12, 1229, 10.1123/jpah.2014-0136 · DOI
  57. Rousset, 2015, Comparison of total energy expenditure assessed by two devices in controlled and free-living conditions, Eur J Sport Sci, 15, 391, 10.1080/17461391.2014.949309 · DOI
  58. Ryan, 2013, Measurement of energy expenditure by activity monitors, Phys Ther Rev, 18, 239, 10.1179/1743288X13Y.0000000063 · DOI
  59. Slinde, 2013, Energy expenditure by multisensor armband in overweight and obese lactating women validated by doubly labeled water, Obesity, 21, 2231, 10.1002/oby.20363 · DOI
  60. 10.1249/MSS.0b013e31825ce76f · DOI
  61. Stackpool, 2013, The accuracy of various activity trackers in estimating steps taken and energy expenditure, J Fit Res, 53, 1689
  62. St-Onge, 2007, Evaluation of a portable device to measure daily energy expenditure in free-living adults, Am J Clin Nutr, 85, 742, 10.1093/ajcn/85.3.742 · DOI · Paper page
  63. Soric, 2012, Validation of the sensewear armband during recreational in-line skating, Eur J Appl Physiol, 112, 1183, 10.1007/s00421-011-2045-6 · DOI
  64. Tucker, 2015, Validity and reliability of Nike + Fuelband for estimating physical activity energy expenditure, BMC Sports Sci Med Rehabil, 7, 14, 10.1186/s13102-015-0008-7 · DOI
  65. 10.1186/1756-0500-5-187 · DOI
  66. 10.1519/JSC.0b013e3182a1f836 · DOI
  67. Van Hoye, 2015, Validation of the sensewear armband in different ambient temperatures, J Sports Sci, 33, 1007, 10.1080/02640414.2014.981846 · DOI
  68. Vernillo, 2015, Validity of the sensewear armband to assess energy expenditure in graded walking, J Phys Act Health, 12, 178, 10.1123/jpah.2013-0437 · DOI
  69. Wahl, 2017, Criterion-validity of commercially available physical activity tracker to estimate step count, covered distance and energy expenditure during sports conditions, Front Physiol, 8, 725, 10.3389/fphys.2017.00725 · DOI · Paper page
  70. 10.3945/ajcn.115.111070 · DOI
  71. Pollard, 2017, Gender differences in walking (for leisure, transport and in total) across adult life: a systematic review, BMC Public Health, 17, 341, 10.1186/s12889-017-4253-4 · doi:10.1186/s12889-017-4253-4
  72. Schneller, 2015, Validation of five minimally obstructive methods to estimate physical activity energy expenditure in young adults in semi-standardized settings, Sensors, 15, 6133, 10.3390/s150306133 · DOI
  73. Welk, 2007, Field validation of the MTI actigraph and bodymedia armband monitor using the IDEEA monitor, Obesity, 15, 918, 10.1038/oby.2007.624 · DOI · Paper page
  74. Montoye, 2016, Comparison of activity type classification accuracy from accelerometers worn on the hip, wrists, and thigh in young, apparently healthy adults, Meas Phys Educ Exerc Sci, 20, 173, 10.1080/1091367X.2016.1192038 · DOI
  75. Plasqui, 2017, Smart approaches for assessing free-living energy expenditure following identification of types of physical activity, Obes Rev, 18 Suppl 1, 50, 10.1111/obr.12506 · DOI
  76. 10.1152/japplphysiol.00092.2006 · DOI · Paper page
  77. 10.1093/ije/dyn204 · DOI · Paper page
  78. Kipp, 2018, Calculating metabolic energy expenditure across a wide range of exercise intensities: the equation matters, Appl Physiol Nutr Metab, 43, 639, 10.1139/apnm-2017-0781 · DOI

Cited by

See all 188

Metadata

Authors
O’Driscoll, R., Turicchi, J., Beaulieu, K., Scott, S., Matu, J., Deighton, K., Finlayson, G., & Stubbs, J.
Venue
British Journal of Sports Medicine
Publisher
BMJ
Published
2018-09-07
Volume
54
Issue
6
Pages
332-340
ISSN
  • 0306-3674 (ISSN-L)
  • 1473-0480
OpenAlex
W2889930586
Cited by
188
References
19
FWCI
2.55
Type
journal article
Language
en
Open access
hybrid
Funders
University of Leeds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: How well do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity of current technologies. https://app.cochat.ai/papers/10.1136/bjsports-2018-099643
The paper
O’Driscoll, R., Turicchi, J., Beaulieu, K., Scott, S., Matu, J., Deighton, K., Finlayson, G., & Stubbs, J. (2020). How well do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity of current technologies. British Journal of Sports Medicine. https://doi.org/10.1136/bjsports-2018-099643

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.