CoChat

Sensitivity and specificity of photography and direct ophthalmoscopy in screening for sight threatening eye disease: the Liverpool diabetic eye study

Open access
Harding, S P, Broadbent, D M, Neoh, C, White, M C, Vora, J · 1995 · BMJ
Cited by 295

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Abstrac: Objective : To evaluate different methods for community based screening for sight threatening diabetic eye disease. Design : Prospective study. Setting : Mobile screening unit visiting inner city community clinics; hospital assessment clinic (tertiary centre). Subjects : 395 diabetic patients registered with four general practices in an inner city location. Interventions : Community based photography with mydriasis and direct ophthalmoscopy through dilated pupils by an experienced ophthalmologist, both compared with reference standard of slit lamp biomicroscopy by a consultant specialist in medical retinal disease. Main outcome measures : Sensitivity and specificity of screening method and prevalence of sight threatening diabetic eye disease (moderate preproliferative retinopathy, circinate maculopathy, exudate within 1 disc diameter of fixation, other diabetes related eye disease). Results : 358 subjects underwent photography, 326 attended hospital clinic for ophthalmoscopy, and six were ungradable on photographs and biomicroscopy, leaving 320 for analysis. Of these 295 (91%) attended clinic within four months of photography. Sensitivity of detection of eye disease by photography was 89% (95% confidence interval 80% to 98%), significantly better than for direct ophthalmoscopy (65% (51% to 79%)). Analysis of patients with false negative results indicated possible improvement of photographic sensitivity to 93% by addition of stereoscopic macular pair photographs. Specificity of detection of sight threatening eye disease was 86% (82% to 90%) for photography and 97% (95% to 99%) for direct ophthalmoscopy. Conclusions : Since high sensitivity is essential for an effective screening programme, a photographic method should be considered as preferred option in national, community based screening programmes. Even in the hands of an experienced ophthalmologist, direct ophthalmoscopy is limited by weaknesses inherent to the instrument.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.311.7013.1131

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

Metadata

Authors
Harding, S. P., Broadbent, D. M., Neoh, C., White, M. C., & Vora, J.
Venue
BMJ
Publisher
BMJ
Published
1995-10-28
Volume
311
Issue
7013
Pages
1131-1135
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W1982722705
Cited by
295
References
22
FWCI
9.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.