Abstract

BACKGROUND/AIMS: Digital retinal imaging using store-and-forward technology is used to screen for diabetic retinopathy (DR). Its usefulness in detecting non-diabetic eye diseases is uncertain. We determined the level of agreement between teleretinal imaging supplemented with visual acuity and intraocular pressure (IOP) measurements (ie, technology-assisted eye (TAE) exam) and a comprehensive eye exam in evaluation for DR and non-diabetic ocular conditions. METHODS: We conducted a prospective, observational study with two parallel evaluations. Patients with diabetes (n=317) had a TAE exam and a comprehensive eye exam on the same day. A subset of participants with normal baseline exams (n=72) had follow-up exams 1 year later. We measured the level of agreement for referable ocular findings. RESULTS: Agreement for referable ocular findings was moderate (n=389, agreement: 77%; κ: 0.55), due in part to ungradable exams (22%). However, about half of the ungradable exams had findings that warranted referral. There was substantial agreement for follow-up exams (n=72, agreement: 93%; κ: 0.63). Among all gradable exams (n=303), the TAE exam had 86% sensitivity and 84% specificity for referable ocular findings, with high agreement (≥94%) for DR and other major ocular diagnoses. CONCLUSIONS: There was moderate-to-substantial agreement between a TAE exam and a comprehensive eye exam for referable ocular findings in patients with diabetes. Ungradable exams were a frequent marker of ocular pathology. Teleretinal imaging may be a useful evaluation for both diabetic and non-diabetic ocular conditions.

Overview

Integrity signals

Registry

Crossref · 10.1136/bjophthalmol-2014-306536

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Cited by

See all 23

Metadata

Authors
Conlin, P. R., Asefzadeh, B., Pasquale, L. R., Selvin, G., Lamkin, R., & Cavallerano, A. A.
Affiliations
  • Harvard University (US)
  • New England College of Optometry (US)
  • Brigham and Women's Hospital (US)
  • VA Boston Healthcare System (US)
Corresponding author
Asefzadeh, Baharak
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2015-05-20
Volume
99
Issue
12
Pages
1622-1627
ISSN
  • 0007-1161 (ISSN-L)
  • 1468-2079
OpenAlex
W1868732297
Cited by
20
References
24
Citations by year
2024: 2 · 2023: 2 · 2022: 4 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 2 · 2016: 1 · 2015: 1
FWCI
1.62
Type
journal article
Language
en
Open access
closed
Locations
  • British Journal of Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (K24DK063214, K24DK63214)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
Keywords
diabetic retinopathy, store-and-forward telemedicine, intraocular pressure, visual acuity, diagnostic agreement
MeSH terms
Aged, Aged, 80 and over, Diabetic Retinopathy, Eye Diseases, False Positive Reactions, Female, Humans, Male, Middle Aged, Photography, Physical Examination, Predictive Value of Tests, Prospective Studies, Referral and Consultation, Sensitivity and Specificity, Visual Acuity, Reproducibility of Results, Telemedicine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of a technology-assisted eye exam in evaluation of referable diabetic retinopathy and concomitant ocular diseases. https://app.cochat.ai/papers/10.1136/bjophthalmol-2014-306536
The paper
Conlin, P. R., Asefzadeh, B., Pasquale, L. R., Selvin, G., Lamkin, R., & Cavallerano, A. A. (2015). Accuracy of a technology-assisted eye exam in evaluation of referable diabetic retinopathy and concomitant ocular diseases. British Journal of Ophthalmology. https://doi.org/10.1136/bjophthalmol-2014-306536

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.