Abstract
OBJECTIVE: To review the spot protein:creatinine ratio and albumin:creatinine ratio as diagnostic tests for significant proteinuria in hypertensive pregnant women. DESIGN: Systematic review. DATA SOURCES: Medline and Embase, the Cochrane Library, reference lists, and experts. Review methods Literature search (1980-2007) for articles of the spot protein:creatinine ratio or albumin:creatinine ratio in hypertensive pregnancy, with 24 hour proteinuria as the comparator. RESULTS: 13 studies concerned the spot protein:creatinine ratio (1214 women with primarily gestational hypertension). Nine studies reported sensitivity and specificity for eight cut-off points, median 24 mg/mmol (range 17-57 mg/mmol; 0.15-0.50 mg/mg). Laboratory assays were not well described. Diagnostic test characteristics were recalculated for a cut-off point of 30 mg/mmol. No significant heterogeneity in cut-off points was found between studies over a range of proteinuria. Pooled values gave a sensitivity of 83.6% (95% confidence interval 77.5% to 89.7%), specificity of 76.3% (72.6% to 80.0%), positive likelihood ratio of 3.53 (2.83 to 4.49), and negative likelihood ratio of 0.21 (0.13 to 0.31) (nine studies, 1003 women). Two studies of the spot albumin:creatinine ratio (225 women) found optimal cut-off points of 2 mg/mmol for proteinuria of 0.3 g/day or more and 27 mg/mmol for albuminuria. CONCLUSION: The spot protein:creatinine ratio is a reasonable "rule-out" test for detecting proteinuria of 0.3 g/day or more in hypertensive pregnancy. Information on use of the albumin:creatinine ratio in these women is insufficient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prediction of Creatinine Clearance from Serum Creatinine
Cockcroft, D. W., & Gault, H. (1976) · Nephron · doi:10.1159/000180580 · Cited by 15,309 · cited 1×
“Secondly, we excluded abstracts as they were unlikely to provide sufficient detail necessary for the review. Thirdly, we have discussed the focus of included studies on inpatients; inadequate reporting of completeness of 24 hour urine collection and its use as the traditional comparator for diagnosing proteinuria; and…”
BackgroundSontrop, J. M., Dixon, S. N., Garg, A. X., Buendia-Jimenez, I., Dohein, O., Huang, S.-H. S., & Clark, W. F. (2013) · American Journal of Nephrology · doi:10.1159/000350377 · Cited by 5,871
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
(2000) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2000.107928 · Cited by 3,270
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Systematic Reviews in Health Care : Meta-Analysis in Context
Egger, M., Smith, G. D., & Altman, D. G. (2000) · Cited by 2,417
Brown, M. A., Lindheimer, M. D., Swiet, M. D., Assche, A. V., & Moutquin, J.-M. (2001) · Hypertension in Pregnancy · doi:10.1081/prg-100104165 · Cited by 1,894 · cited 1×
“Providers of obstetric care must be familiar with the diagnosis of pre-eclampsia, the hypertensive condition associated with the highest risk of adverse maternal and perinatal complications and a condition that affects 2-5% of pregnancies.”
BackgroundSelf-citationSystematic Reviews in Health Care. Meta-analysis in Context.
Kleijnen, J., & Antes, G. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.3.697 · Cited by 1,363
Cited by
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Steegers, E. A., von Dadelszen, P., Duvekot, J. J., & Pijnenborg, R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60279-6 · Cited by 2,850
Brown, M. A., Magee, L. A., Kenny, L. C., Karumanchi, S. A., McCarthy, F. P., Saito, S., Hall, D. R., Warren, C. E., Adoyi, G., & Ishaku, S. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10803 · Cited by 2,089
Self-citationTranquilli, A. L., Dekker, G., Magee, L., Roberts, J., Sibai, B. M., Steyn, W., Zeeman, G. G., & Brown, M. A. (2014) · Pregnancy Hypertension: An International Journal of Women's Cardiovascular Health · doi:10.1016/j.preghy.2014.02.001 · Cited by 1,417
Self-citationMagee, L. A., Brown, M. A., Hall, D. R., Gupte, S., Hennessy, A., Karumanchi, S. A., Kenny, L. C., McCarthy, F., Myers, J., Poon, L. C., et al. (2022) · Pregnancy Hypertension · doi:10.1016/j.preghy.2021.09.008 · Cited by 1,134
Self-citationChapter 1: Definition and classification of CKD
(2013) · Kidney International Supplements · doi:10.1038/kisup.2012.64 · Cited by 1,110
Brown, M. A., Magee, L. A., Kenny, L. C., Karumanchi, S. A., McCarthy, F. P., Saito, S., Hall, D. R., Warren, C. E., Adoyi, G., & Ishaku, S. (2018) · Pregnancy Hypertension · doi:10.1016/j.preghy.2018.05.004 · Cited by 1,067
Self-citationPre-eclampsia part 1: current understanding of its pathophysiology
Chaiworapongsa, T., Chaemsaithong, P., Yeo, L., & Romero, R. (2014) · Nature Reviews Nephrology · doi:10.1038/nrneph.2014.102 · Cited by 956
Chappell, L. C., Cluver, C. A., Kingdom, J., & Tong, S. (2021) · The Lancet · doi:10.1016/s0140-6736(20)32335-7 · Cited by 925
RETIRED: Diagnosis, Evaluation, and Management of the Hypertensive Disorders of Pregnancy
Magee, L. A., Helewa, M., Rey, E., Cardew, S., Côté, A.-M., Douglas, M. J., Firoz, T., Gibson, P. S., Gruslin A., A., Lange, I., et al. (2008) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)32776-1 · Cited by 578
Self-citationDiagnosis, evaluation, and management of the hypertensive disorders of pregnancy
Magee, L. A., Pels, A., Helewa, M., Rey, E., & von Dadelszen, P. (2014) · Pregnancy Hypertension: An International Journal of Women's Cardiovascular Health · doi:10.1016/j.preghy.2014.01.003 · Cited by 448
Self-citationPreeclampsia: Risk Factors, Diagnosis, Management, and the Cardiovascular Impact on the Offspring
Fox, R., Kitt, J., Leeson, P., Aye, C. Y. L., & Lewandowski, A. J. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8101625 · Cited by 440
SOMANZ guidelines for the management of hypertensive disorders of pregnancy 2014
Lowe, S. A., Bowyer, L., Lust, K., McMahon, L. P., Morton, M., North, R. A., Paech, M., & Said, J. M. (2015) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/ajo.12399 · Cited by 299
Clinical practice guideline on pregnancy and renal disease
Wiles, K., Chappell, L., Clark, K., Elman, L., Hall, M., Lightstone, L., Mohamed, G., Mukherjee, D., Nelson-Piercy, C., Webster, P., et al. (2019) · BMC Nephrology · doi:10.1186/s12882-019-1560-2 · Cited by 275
How should proteinuria be detected and measured?
Lamb, E. J., MacKenzie, F., & Stevens, P. E. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009007 · Cited by 271
Acestor, N., Goett, J., Lee, A., Herrick, T. M., Engelbrecht, S. M., Harner-Jay, C. M., Howell, B. J., & Weigl, B. H. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0069 · Cited by 268
Chronic kidney disease and measurement of albuminuria or proteinuria: a position statement
Johnson, D. W., Jones, G. R. D., Mathew, T. H., Ludlow, M. J., Chadban, S. J., Usherwood, T., Polkinghorne, K., Colagiuri, S., Jerums, G., MacIsaac, R., et al. (2012) · Medical Journal of Australia · doi:10.5694/mja11.11468 · Cited by 231
Abnormal Placentation, Angiogenic Factors, and the Pathogenesis of Preeclampsia
Silasi, M., Cohen, B., Karumanchi, S. A., & Rana, S. (2010) · Obstetrics and Gynecology Clinics of North America · doi:10.1016/j.ogc.2010.02.013 · Cited by 196
“A meta-analysis showed a pooled sensitivity of 84% and specificity of 76% using P:C ratio cutoff of greater than 30 mg/mmol, as compared with the gold standard of 24-hour urine protein excretion greater than 300 mg/d.(11)”
MethodMorris, R. K., Riley, R. D., Doug, M., Deeks, J. J., & Kilby, M. D. (2012) · BMJ · doi:10.1136/bmj.e4342 · Cited by 179
Isolated gestational proteinuria preceding the diagnosis of preeclampsia – an observational study
Yamada, T., Obata‐Yasuoka, M., Hamada, H., Baba, Y., Ohkuchi, A., Yasuda, S., Kawabata, K., Minakawa, S., Hirai, C., Kusaka, H., et al. (2016) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1111/aogs.12915 · Cited by 43
Metadata
- Authors
- Côté, A.-M., Brown, M. A., Lam, E., Dadelszen, P. V., Firoz, T., Liston, R. M., & Magee, L. A.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2008-04-10
- Volume
- 336
- Issue
- 7651
- Pages
- 1003-1006
- ISSN
- 1756-1833 (ISSN-L)
- 0959-8138
- OpenAlex
- W1998442968
- Cited by
- 235
- References
- 35
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.