The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial
Open accessAbstract
OBJECTIVE: To compare the quality and accuracy of manual office blood pressure and automated office blood pressure using the awake ambulatory blood pressure as a gold standard. DESIGN: Multi-site cluster randomised controlled trial. SETTING: Primary care practices in five cities in eastern Canada. PARTICIPANTS: 555 patients with systolic hypertension and no serious comorbidities under the care of 88 primary care physicians in 67 practices in the community. INTERVENTIONS: Practices were randomly allocated to either ongoing use of manual office blood pressure (control group) or automated office blood pressure (intervention group) using the BpTRU device. The last routine manual office blood pressure (mm Hg) was obtained from each patient's medical record before enrollment. Office blood pressure readings were compared before and after enrollment in the intervention and control groups; all readings were also compared with the awake ambulatory blood pressure. MAIN OUTCOME MEASURE: Difference in systolic blood pressure between awake ambulatory blood pressure minus automated office blood pressure and awake ambulatory blood pressure minus manual office blood pressure. RESULTS: Cluster randomisation allocated 31 practices (252 patients) to manual office blood pressure and 36 practices (303 patients) to automated office blood pressure measurement. The most recent routine manual office blood pressure (149.5 (SD 10.8)/81.4 (8.3)) was higher than automated office blood pressure (135.6 (17.3)/77.7 (10.9)) (P < 0.001). In the control group, routine manual office blood pressure before enrollment (149.9 (10.7)/81.8 (8.5)) was reduced to 141.4 (14.6)/80.2 (9.5) after enrollment (P < 0.001/P = 0.01), but the reduction in the intervention group from manual office to automated office blood pressure was significantly greater (P < 0.001/P = 0.02). On the first study visit after enrollment, the estimated mean difference for the intervention group between the awake ambulatory systolic/diastolic blood pressure and automated office blood pressure (-2.3 (95% confidence interval -0.31 to -4.3)/-3.3 (-2.7 to -4.4)) was less (P = 0.006/P = 0.26) than the difference in the control group between the awake ambulatory blood pressure and the manual office blood pressure (-6.5 (-4.3 to -8.6)/-4.3 (-2.9 to -5.8)). Systolic/diastolic automated office blood pressure showed a stronger (P < 0.001) within group correlation (r = 0.34/r = 0.56) with awake ambulatory blood pressure after enrollment compared with manual office blood pressure versus awake ambulatory blood pressure before enrollment (r = 0.10/r = 0.40); the mean difference in r was 0.24 (0.12 to 0.36)/0.16 (0.07 to 0.25)). The between group correlation comparing diastolic automated office blood pressure and awake ambulatory blood pressure (r = 0.56) was stronger (P < 0.001) than that for manual office blood pressure versus awake ambulatory blood pressure (r = 0.30); the mean difference in r was 0.26 (0.09 to 0.41). Digit preference with readings ending in zero was substantially reduced by use of automated office blood pressure. CONCLUSION: In compliant, otherwise healthy, primary care patients with systolic hypertension, introduction of automated office blood pressure into routine primary care significantly reduced the white coat response compared with the ongoing use of manual office blood pressure measurement. The quality and accuracy of automated office blood pressure in relation to the awake ambulatory blood pressure was also significantly better when compared with manual office blood pressure. Trial registration Clinical trials NCT 00214053.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Authors/Task Force Members:, Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehm236 · Cited by 2,384
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Design and Analysis of Cluster Randomization Trials in Health Research
DONNER, A. P., & Klar, N. S. (2000) · Cited by 1,236
How Common Is White Coat Hypertension?
Pickering, T. G. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03720020027031 · Cited by 1,190
Design and Analysis of Cluster Randomization Trials in Health Research.
Flynn, T. N. (2001) · International Journal of Epidemiology · doi:10.1093/ije/30.2.407-a · Cited by 469
Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society Protocol
O??Brien, E., Mee, F., Atkins, N., & O??Malley, K. (1991) · Journal of Hypertension · doi:10.1097/00004872-199106000-00016 · Cited by 451
Elliott, W. J. (2006) · Yearbook of Cardiology · doi:10.1016/s0145-4145(07)70004-7 · Cited by 390
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Self-citationWhite, W. B., & Anwar, Y. A. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200104000-00007 · Cited by 213
Use of automated office blood pressure measurement to reduce the white coat response
Myers, M. G., Valdivieso, M., & Kiss, A. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e32831b9e6b · Cited by 209
Self-citationHead, G. A., Mihailidou, A. S., Duggan, K. A., Beilin, L. J., Berry, N., Brown, M. A., Bune, A. J., Cowley, D., Chalmers, J. P., Howe, P. R. C., et al. (2010) · BMJ · doi:10.1136/bmj.c1104 · Cited by 185
Staessen, J. A. (1997) · JAMA · doi:10.1001/jama.1997.03550130039034 · Cited by 176
Beckett, L., & Godwin, M. (2005) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-5-18 · Cited by 175
Self-citationDoes This Patient Have Hypertension? How to Measure Blood Pressure
Reeves, R. A. (1995) · JAMA · doi:10.1001/jama.273.15.1211 · Cited by 172
Does This Patient Have Hypertension?
Reeves, R. A. (1995) · JAMA · doi:10.1001/jama.1995.03520390071036 · Cited by 154
Stergiou, G. S., Tzamouranis, D., Protogerou, A. D., Nasothimiou, E. G., & Kapralos, C. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283057af6 · Cited by 119
Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor
Wright, J. M., Mattu, G. S., Perry, T. L., Gelferc, M. E., Strange, K. D., Zorn, A., & Chen, Y. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200106000-00008 · Cited by 114
Pickering, T. G., Gerin, W., Schwartz, J. E., Spruill, T. M., & Davidson, K. W. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e32831313c4 · Cited by 89
Myers, M. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00058-x · Cited by 87
Self-citationAmbulatory Blood Pressure Measurement: The Case for Implementation in Primary Care
O'Brien, E. T. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100008 · Cited by 86
How Long Shall the Patient Rest Before Clinic Blood Pressure Measurement?
SALA, C., Santin, E., Rescaldani, M., & Magrini, F. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.08.021 · Cited by 86
Home Blood Pressure as a Cardiovascular Outcome Predictor: It’s Time to Take This Method Seriously
Stergiou, G. S., Siontis, K. C. M., & Ioannidis, J. P. A. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.150771 · Cited by 84
Parati, G., Omboni, S., & Bilo, G. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.122853 · Cited by 82
Consistent relationship between automated office blood pressure recorded in different settings
Myers, M. G., Valdivieso, M., & Kiss, A. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32832c5167 · Cited by 77
Self-citationVerdecchia, P., Clement, D. L., Fagard, R. H., Palatini, P., & Parati, G. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199900460-00004 · Cited by 77
Task Force III: Target-organ damage, morbidity and mortality
Verdecchia, P., Clement, D., Fagard, R., Palatini, P., & Parati, G. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199912000-00004 · Cited by 75
Automated blood pressure measurement in routine clinical practice
Myers, M. G. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000200481.64787.c0 · Cited by 74
Self-citationA proposed algorithm for diagnosing hypertension using automated office blood pressure measurement
Myers, M. G. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e328335d091 · Cited by 72
Self-citationManual and automated office measurements in relation to awake ambulatory blood pressure monitoring
Godwin, M., Birtwhistle, R., Delva, D., Lam, M., Casson, I., MacDonald, S., & Seguin, R. (2010) · Family Practice · doi:10.1093/fampra/cmq067 · Cited by 68
Self-citationOptimum frequency of office blood pressure measurement using an automated sphygmomanometer
Myers, M. G., Valdivieso, M., & Kiss, A. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283104247 · Cited by 61
Self-citationHome Blood Pressure Measurements Will Not Replace 24-Hour Ambulatory Blood Pressure Monitoring
Verdecchia, P., Angeli, F., Mazzotta, G., Gentile, G., & Reboldi, G. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.122861 · Cited by 58
Comparison of two automated sphygmomanometers for use in the office setting
Myers, M. G., Valdivieso, M., Kiss, A., & Tobe, S. W. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32831e314f · Cited by 42
Self-citationMyers, M. G., Valdivieso, M., Chessman, M., & Kiss, A. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328340d128 · Cited by 37
Self-citationGiles, T. D., & Egan, P. (2008) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2008.08084.x · Cited by 8
Cited by
Zhou, B., Carrillo-Larco, R. M., Danaei, G., Riley, L. M., Paciorek, C. J., Stevens, G. A., Gregg, E. W., Bennett, J. E., Solomon, B., Singleton, R. K., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01330-1 · Cited by 3,902
Zhou, B., Bentham, J., Di Cesare, M., Bixby, H., Danaei, G., Cowan, M. J., Paciorek, C. J., Singh, G., Hajifathalian, K., Bennett, J. E., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(16)31919-5 · Cited by 2,579
2024 ESC Guidelines for the management of elevated blood pressure and hypertension
McEvoy, J. W., McCarthy, C. P., Bruno, R. M., Brouwers, S., Canavan, M. D., Ceconi, C., Christodorescu, R. M., Daskalopoulou, S. S., Ferro, C. J., Gerdts, E., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae178 · Cited by 2,298
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Self-citationZhou, B., Danaei, G., Stevens, G. A., Bixby, H., Taddei, C., Carrillo-Larco, R. M., Solomon, B., Riley, L. M., Di Cesare, M., Iurilli, M. L. C., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31145-6 · Cited by 544
Metadata
- Authors
- Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., Grant, F. C., & Kaczorowski, J.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2011-02-07
- Volume
- 342
- Issue
- feb07 1
- Pages
- d286-d286
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2132190388
- Cited by
- 285
- References
- 38
- FWCI
- 16.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.