Use of artificial intelligence for image analysis in breast cancer screening programmes: systematic review of test accuracy

Open access
Freeman, Karoline, Geppert, Julia, Stinton, Chris, Todkill, Daniel, Johnson, Samantha, Clarke, Aileen, Taylor-Phillips, Sian · 2021 · BMJ

Abstract

Objective: To examine the accuracy of artificial intelligence (AI) for the detection of breast cancer in mammography screening practice. Design: Systematic review of test accuracy studies. Data sources: Medline, Embase, Web of Science, and Cochrane Database of Systematic Reviews from 1 January 2010 to 17 May 2021. Eligibility criteria: Studies reporting test accuracy of AI algorithms, alone or in combination with radiologists, to detect cancer in women’s digital mammograms in screening practice, or in test sets. Reference standard was biopsy with histology or follow-up (for screen negative women). Outcomes included test accuracy and cancer type detected. Study selection and synthesis: Two reviewers independently assessed articles for inclusion and assessed the methodological quality of included studies using the QUality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. A single reviewer extracted data, which were checked by a second reviewer. Narrative data synthesis was performed. Results: Twelve studies totalling 131 822 screened women were included. No prospective studies measuring test accuracy of AI in screening practice were found. Studies were of poor methodological quality. Three retrospective studies compared AI systems with the clinical decisions of the original radiologist, including 79 910 women, of whom 1878 had screen detected cancer or interval cancer within 12 months of screening. Thirty four (94%) of 36 AI systems evaluated in these studies were less accurate than a single radiologist, and all were less accurate than consensus of two or more radiologists. Five smaller studies (1086 women, 520 cancers) at high risk of bias and low generalisability to the clinical context reported that all five evaluated AI systems (as standalone to replace radiologist or as a reader aid) were more accurate than a single radiologist reading a test set in the laboratory. In three studies, AI used for triage screened out 53%, 45%, and 50% of women at low risk but also 10%, 4%, and 0% of cancers detected by radiologists. Conclusions: Current evidence for AI does not yet allow judgement of its accuracy in breast cancer screening programmes, and it is unclear where on the clinical pathway AI might be of most benefit. AI systems are not sufficiently specific to replace radiologist double reading in screening programmes. Promising results in smaller studies are not replicated in larger studies. Prospective studies are required to measure the effect of AI in clinical practice. Such studies will require clear stopping rules to ensure that AI does not reduce programme specificity. Study registration: Protocol registered as PROSPERO CRD42020213590.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.n1872

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Overview of published evidence in relation to proposed role in screening pathway. Purple shade=current pathway; orange shade=AI added to pathway; green shade=level of evidence for proposed AI role. AI=artificial intelligence; +/−=high/low risk of breast cancer, person icon=radiologist reading of mammograms as single, first, or second reader; MRMC=multiple reader multiple case; R1, R2=reader 1, reader 2; RCT, randomised controlled trial; sens=sensitivity; spec=specificity
Fig 1 Overview of published evidence in relation to proposed role in screening pathway. Purple shade=current pathway; orange shade=AI added to pathway; green shade=level of evidence for proposed AI role. AI=artificial intelligence; +/−=high/low risk of breast cancer, person icon=radiologist reading of mammograms as single, first, or second reader; MRMC=multiple reader multiple case; R1, R2=reader 1, reader 2; RCT, randomised controlled trial; sens=sensitivity; spec=specificityCC BY-NC · PubMed Central
Fig 2 Overview of concerns about risk of bias and applicability of included studies. *Low concerns about applicability for consensus reading; high concerns about applicability for single reading as comparator test. †Low concerns about risk of bias and low applicability for the previous screening round (biopsy proven cancer or at least two years’ follow-up); high concerns about risk of bias and high applicability for the current screening round (biopsy-proven cancer but no follow-up of test negatives)
Fig 2 Overview of concerns about risk of bias and applicability of included studies. *Low concerns about applicability for consensus reading; high concerns about applicability for single reading as comparator test. †Low concerns about risk of bias and low applicability for the previous screening round (biopsy proven cancer or at least two years’ follow-up); high concerns about risk of bias and high applicability for the current screening round (biopsy-proven cancer but no follow-up of test negatives)CC BY-NC · PubMed Central
Fig 3 Study estimates of sensitivity and false positive rate (1−specificity) in receiver operating characteristic space by index test (artificial intelligence) and comparator (radiologist) for eight included studies. Comparators are defined as consensus of two readers and arbitration (radiologist consensus), or single reader decision/average of multiple readers (radiologist single/average). iVertical dashed lines represent specificity for screening programmes for Denmark (2% false positive rate),61 UK (3% false positive rate),62 63 and US (11% false positive rate).64 Retrospective test accuracy studies: Salim et al,35 Schaffter et al,36 and McKinney et al.29 Enriched test set multiple reader multiple case laboratory studies: Pacilè et al,30 Watanabe et al,37 Rodriguez-Ruiz et al33 (Rodriguez-Ruiz 2019a in figure), Lotter 2021,28 and Rodriguez-Ruiz et al32 (Rodriguez-Ruiz 2019b in figure)
Fig 3 Study estimates of sensitivity and false positive rate (1−specificity) in receiver operating characteristic space by index test (artificial intelligence) and comparator (radiologist) for eight included studies. Comparators are defined as consensus of two readers and arbitration (radiologist consensus), or single reader decision/average of multiple readers (radiologist single/average). iVertical dashed lines represent specificity for screening programmes for Denmark (2% false positive rate),61 UK (3% false positive rate),62 63 and US (11% false positive rate).64 Retrospective test accuracy studies: Salim et al,35 Schaffter et al,36 and McKinney et al.29 Enriched test set multiple reader multiple case laboratory studies: Pacilè et al,30 Watanabe et al,37 Rodriguez-Ruiz et al33 (Rodriguez-Ruiz 2019a in figure), Lotter 2021,28 and Rodriguez-Ruiz et al32 (Rodriguez-Ruiz 2019b in figure)CC BY-NC · PubMed Central
Fig 4 Study estimates of sensitivity and false positive rate (1−specificity) in receiver operating characteristic space for studies of artificial intelligence (AI) as a pre-screen (A) or post-screen (B). Pre-screen requires very high sensitivity, but can have modest specificity, post-screen requires very high specificity, but can have modest sensitivity. Reference standard for test negatives was double reading not follow-up. (A) Dembrower 2020a: retrospective study using AI (Lunit version 5.5.0.16) for pre-screen (point estimates not based on exact numbers). Reference standard includes only screen detected cancers. No data reported for radiologists.26 Balta 2020 (Transpara version 1.6.0),25 Raya-Povedano 2021 (Transpara version 1.6.0),31 and Lång 2020 (Transpara version 1.4.0)27: retrospective studies using AI as pre-screen. Reference standard includes only screen detected cancers. (B) Dembrower 2020b: retrospective study using AI (Lunit version 5.5.0.16) for post-screen detection of interval cancers,26 Dembrower 2020c: retrospective study using AI (Lunit version 5.5.0.16) for post-screen detection of interval cancers and next round screen detected cancers.26 Thresholds highlighted represent thresholds specified in studies. Radiologist double reading for this cohort would be 100% specificity and 0% sensitivity as this was only in a cohort of women with screen (true and false) negative mammograms
Fig 4 Study estimates of sensitivity and false positive rate (1−specificity) in receiver operating characteristic space for studies of artificial intelligence (AI) as a pre-screen (A) or post-screen (B). Pre-screen requires very high sensitivity, but can have modest specificity, post-screen requires very high specificity, but can have modest sensitivity. Reference standard for test negatives was double reading not follow-up. (A) Dembrower 2020a: retrospective study using AI (Lunit version 5.5.0.16) for pre-screen (point estimates not based on exact numbers). Reference standard includes only screen detected cancers. No data reported for radiologists.26 Balta 2020 (Transpara version 1.6.0),25 Raya-Povedano 2021 (Transpara version 1.6.0),31 and Lång 2020 (Transpara version 1.4.0)27: retrospective studies using AI as pre-screen. Reference standard includes only screen detected cancers. (B) Dembrower 2020b: retrospective study using AI (Lunit version 5.5.0.16) for post-screen detection of interval cancers,26 Dembrower 2020c: retrospective study using AI (Lunit version 5.5.0.16) for post-screen detection of interval cancers and next round screen detected cancers.26 Thresholds highlighted represent thresholds specified in studies. Radiologist double reading for this cohort would be 100% specificity and 0% sensitivity as this was only in a cohort of women with screen (true and false) negative mammogramsCC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Research works printed but not linked: 7

  1. 10.1148/radiology.160.2.3523590 · doi:10.1148/radiology.160.2.3523590
  2. 10.1016/j.ejca.2014.03.017 · doi:10.1016/j.ejca.2014.03.017
  3. 10.1038/s41591-020-0776-9 · DOI
  4. 10.1101/2020.09.13.20193565 · doi:10.1101/2020.09.13.20193565
  5. 10.1001/jamanetworkopen.2020.18179 · doi:10.1001/jamanetworkopen.2020.18179
  6. Balta C Rodriguez-Ruiz A Mieskes C Karssemeijer N Heywang-Köbrunner SH . Going from double to single reading for screening exams labeled as likely normal by AI: what is the impact? Proc SPIE 2020;11513:115130D. · doi:10.1117/12.2564179
  7. 10.1186/s12885-017-3929-6 · doi:10.1186/s12885-017-3929-6

Cited by

Metadata

Authors
Freeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S.
Venue
BMJ
Publisher
BMJ
Published
2021-09-01
Volume
374
Pages
n1872
ISSN
1756-1833 (ISSN-L)
OpenAlex
W3197840494
Cited by
338
References
56
FWCI
5.53
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.