Digital eye strain: prevalence, measurement and amelioration
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Digital device usage has increased substantially in recent years across all age groups, so that extensive daily use for both social and professional purposes is now normal. Digital eye strain (DES), also known as computer vision syndrome, encompasses a range of ocular and visual symptoms, and estimates suggest its prevalence may be 50% or more among computer users. Symptoms fall into two main categories: those linked to accommodative or binocular vision stress, and external symptoms linked to dry eye. Although symptoms are typically transient, they may be frequent and persistent, and have an economic impact when vocational computer users are affected. DES may be identified and measured using one of several available questionnaires, or objective evaluations of parameters such as critical flicker–fusion frequency, blink rate and completeness, accommodative function and pupil characteristics may be used to provide indices of visual fatigue. Correlations between objective and subjective measures are not always apparent. A range of management approaches exist for DES including correction of refractive error and/or presbyopia, management of dry eye, incorporating regular screen breaks and consideration of vergence and accommodative problems. Recently, several authors have explored the putative role of blue light-filtering spectacle lenses on treating DES, with mixed results. Given the high prevalence of DES and near-universal use of digital devices, it is essential that eye care practitioners are able to provide advice and management options based on quality research evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phototransduction by retinal ganglion cells that set the circadian clock
Berson, D. M., Dunn, F. A., & Takao, M. (2002) · Science · doi:10.1126/science.1067262 · Cited by 3,629 · cited 1×
“Its release from the pineal gland is controlled by a pathway originating from the intrinsically photosensitive retinal ganglion cells containing melanopsin, which has a peak sensitivity of approximately 482 nm, 94 that is, longer wavelength blue-turquoise light.”
BackgroundTFOS DEWS II Diagnostic Methodology report
Wolffsohn, J. S., Arita, R., Chalmers, R., Djalilian, A., Dogru, M., Dumbleton, K., Gupta, P. K., Karpecki, P., Lazreg, S., Pult, H., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.001 · Cited by 2,122
Self-citation(2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70082-4 · Cited by 1,227
Computer Vision Syndrome: A Review
Blehm, C., Vishnu, S., Khattak, A., Mitra, S., & Yee, R. W. (2005) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2005.02.008 · Cited by 860
Cajochen, C., Frey, S., Anders, D., Späti, J., Bues, M., Pross, A., Mager, R., Wirz-Justice, A., & Stefani, O. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00165.2011 · Cited by 730 · cited 1×
“Exposure to short wavelength light (including digital devices) before bedtime can disrupt sleep patterns, 95 96 while use of short wavelength blocking spectacles in the evening can improve sleep duration and quality 97 98 and reduce subjective alertness.”
BackgroundComputer vision syndrome: a review of ocular causes and potential treatments
Rosenfield, M. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00834.x · Cited by 726
Retinal sensitivity to damage from short wavelength light
HAM, W. T., MUELLER, H. A., & SLINEY, D. H. (1976) · Nature · doi:10.1038/260153a0 · Cited by 703
Effects of blue light on the circadian system and eye physiology
Tosini, G., Ferguson, I., & Tsubota, K. (2016) · Molecular Vision · doi:10.63500/mv_v22_61 · Cited by 517 · cited 1×
“Longer duration, less intense light exposure can also induce photochemical damage.(90)While some concern has been expressed regarding blue light emitted from digital screens, recent research indicated that the low levels of blue light from such devices do not represent a biohazard, even for long-term viewing.”
BackgroundDry Eyes and Video Display Terminals
Tsubota, K., & Nakamori, K. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302253280817 · Cited by 435
Seguí, M. D. M., Cabrero-García, J., Crespo, A., Verdú, J., & Ronda, E. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2015.01.015 · Cited by 398
Sheedy, J. E., HAYES, J., & ENGLE, A. J. (2002) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2002.tb04090.x · Cited by 306
Moon, J. H., Kim, K. W., & Moon, N. J. (2016) · BMC Ophthalmology · doi:10.1186/s12886-016-0364-4 · Cited by 292
van der Lely, S., Frey, S., Garbazza, C., Wirz-Justice, A., Jenni, O. G., Steiner, R., Wolf, S., Cajochen, C., Bromundt, V., & Schmidt, C. (2015) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2014.08.002 · Cited by 290
Touitou, Y., Touitou, D., & Reinberg, A. (2016) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2017.05.001 · Cited by 290
Font Size and Viewing Distance of Handheld Smart Phones
Bababekova, Y., Rosenfield, M., Hue, J. E., & Huang, R. R. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182198792 · Cited by 277
Children under five and digital technologies: implications for early years pedagogy
Palaiologou, I. (2016) · European Early Childhood Education Research Journal · doi:10.1080/1350293x.2014.929876 · Cited by 257
Computer Use, Symptoms, and Quality of Life
HAYES, J. R., SHEEDY, J. E., STELMACK, J. A., & HEANEY, C. A. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e31812f7546 · Cited by 246
Blink Rate, Incomplete Blinks and Computer Vision Syndrome
Portello, J. K., Rosenfield, M., & Chu, C. A. (2013) · Optometry and Vision Science · doi:10.1097/opx.0b013e31828f09a7 · Cited by 240
Violet Light Exposure Can Be a Preventive Strategy Against Myopia Progression
Torii, H., Kurihara, T., Seko, Y., Negishi, K., Ohnuma, K., Inaba, T., Kawashima, M., Jiang, X., Kondo, S., Miyauchi, M., et al. (2017) · EBioMedicine · doi:10.1016/j.ebiom.2016.12.007 · Cited by 230
Blinking and Tear Break-Up During Four Visual Tasks
Himebaugh, N. L., Begley, C. G., Bradley, A., & Wilkinson, J. A. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e318194e962 · Cited by 228
Courtin, R., Pereira, B., Naughton, G., Chamoux, A., Chiambaretta, F., Lanhers, C., & Dutheil, F. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-009675 · Cited by 224
Retinal damage induced by commercial light emitting diodes (LEDs)
Jaadane, I., Boulenguez, P., Chahory, S., Carré, S., Savoldelli, M., Jonet, L., Behar-Cohen, F., Martinsons, C., & Torriglia, A. (2015) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2015.03.034 · Cited by 214
Benedetto, S., Drai-Zerbib, V., Pedrotti, M., Tissier, G., & Baccino, T. (2013) · PLoS ONE · doi:10.1371/journal.pone.0083676 · Cited by 213
McMonnies, C. W. (2007) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2006.12.002 · Cited by 194
Blue-Light Filtering Spectacle Lenses: Optical and Clinical Performances
Leung, T.-W., Li, R. W., & Kee, C. (2017) · PLoS ONE · doi:10.1371/journal.pone.0169114 · Cited by 194
Low-energy light bulbs, computers, tablets and the blue light hazard
O'Hagan, J. B., Khazova, M., & Price, L. L. A. (2016) · Eye · doi:10.1038/eye.2015.261 · Cited by 191
Viewing distance and eyestrain symptoms with prolonged viewing of smartphones
Long, J., Cheung, R., Duong, S., Paynter, R., & Asper, L. (2017) · Clinical and Experimental Optometry · doi:10.1111/cxo.12453 · Cited by 185
ACOSTA, M. C., GALLAR, J., & BELMONTE, C. (1999) · Experimental Eye Research · doi:10.1006/exer.1998.0656 · Cited by 182
Association Between Video Display Terminal Use and Dry Eye Disease in School Children
Moon, J. H., Lee, M. Y., & Moon, N. J. (2014) · Journal of Pediatric Ophthalmology & Strabismus · doi:10.3928/01913913-20140128-01 · Cited by 178
Lawrenson, J. G., Hull, C. C., & Downie, L. E. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12406 · Cited by 169
Krigel, A., Berdugo, M., Picard, É., Levy, R., Jaadane, I., Jonet, L., Dernigoghossian, M., Andrieu‐Soler, C., Torriglia, A., & Béhar‐Cohen, F. (2016) · Neuroscience · doi:10.1016/j.neuroscience.2016.10.015 · Cited by 167
Argilés, M., Cardona, G., Pérez-Cabré, E., & Rodríguez, M. (2015) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-16967 · Cited by 159
Supplementary breaks and stretching exercises for data entry operators: a follow-up field study.
Galinsky, T., Swanson, N., Sauter, S., Dunkin, R., Hurrell, J., & Schleifer, L. (2007) · American Journal of Industrial Medicine · doi:10.1002/ajim.20472 · Cited by 156
The effect of work-rest schedules and type of task on the discomfort and performance of VDT users
BALCI, R., & AGHAZADEH, F. (2003) · Ergonomics · doi:10.1080/0014013021000047557 · Cited by 146
Proof-reading texts on screen and paper
WRIGHT, P., & LICKORISH, A. (1983) · Behaviour & Information Technology · doi:10.1080/01449298308914479 · Cited by 145
Freudenthaler, N., Neuf, H., Kadner, G., & Schlote, T. (2003) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-003-0786-6 · Cited by 135
Short-Wavelength Light-Blocking Eyeglasses Attenuate Symptoms of Eye Fatigue
Lin, J. B., Gerratt, B. W., Bassi, C. J., & Apte, R. S. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-20663 · Cited by 132
The Computer-Vision Symptom Scale (CVSS17): Development and Initial Validation
González‐Pérez, M., García, R. S., Antona, B., Barrio, A. R., & González-Romero, E. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-13818 · Cited by 130
A comparison of symptoms after viewing text on a computer screen and hardcopy
Chu, C. A., Rosenfield, M., Portello, J. K., Benzoni, J. A., & Collier, J. D. (2010) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2010.00802.x · Cited by 124
Oral omega-3 fatty acids treatment in computer vision syndrome related dry eye
Bhargava, R., Kumar, P., Phogat, H., Kaur, A., & Kumar, M. (2015) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2015.01.007 · Cited by 103 · cited 1×
“62 Given the impact of digital device usage on blinking characteristics, blink training may be helpful in the management of DES symptoms linked to dry eye.”
BackgroundEffect of Blue Light–Reducing Eye Glasses on Critical Flicker Frequency
Ide, T., Toda, I., Miki, E., & Tsubota, K. (2014) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000069 · Cited by 96
Proof-reading: VDU and paper text compared for speed, accuracy and fatigue
Wilkinson*, R. T., & Robinshaw, H. M. (1987) · Behaviour & Information Technology · doi:10.1080/01449298708901822 · Cited by 93
Accommodation and convergence during sustained computer work
Collier, J. D., & Rosenfield, M. (2011) · Optometry · doi:10.1016/j.optm.2010.10.013 · Cited by 86
Preferred viewing distance and screen angle of electronic paper displays
Shieh, K.-K., & Lee, D. (2006) · Applied Ergonomics · doi:10.1016/j.apergo.2006.06.008 · Cited by 85
Cognitive demand, digital screens and blink rate
Rosenfield, M., Jahan, S., Nunez, K., & Chan, K. (2015) · Computers in Human Behavior · doi:10.1016/j.chb.2015.04.073 · Cited by 78
Ayaki, M., Hattori, A., Maruyama, Y., Nakano, M., Yoshimura, M., Kitazawa, M., Negishi, K., & Tsubota, K. (2016) · Chronobiology International · doi:10.3109/07420528.2015.1119158 · Cited by 77 · cited 1×
“Exposure to short wavelength light (including digital devices) before bedtime can disrupt sleep patterns, 95 96 while use of short wavelength blocking spectacles in the evening can improve sleep duration and quality 97 98 and reduce subjective alertness.”
BackgroundAttenuation of short wavelengths alters sleep and the ip RGC pupil response
Ostrin, L. A., Abbott, K. S., & Queener, H. M. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12385 · Cited by 69 · cited 1×
“Exposure to short wavelength light (including digital devices) before bedtime can disrupt sleep patterns, 95 96 while use of short wavelength blocking spectacles in the evening can improve sleep duration and quality 97 98 and reduce subjective alertness.”
BackgroundElectronic paper display preferred viewing distance and character size for different age groups
Wu, H. (2011) · Ergonomics · doi:10.1080/00140139.2011.600775 · Cited by 43
Objective Measurements of Lower‐Level Visual Stress
Nahar, N. K., Sheedy, J. E., Hayes, J. D., & Tai, Y.-C. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e3180dc99a8 · Cited by 39
Horgen, G., Aarås, A., & Thoresen, M. (2004) · Optometry and Vision Science · doi:10.1097/01.opx.0000134908.44145.49 · Cited by 31
Towards human work: solutions to problems in occupational health and safety
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90159-s · Cited by 29
Recent Advances in the Management of Age-Related Macular Degeneration
Mittra, R. A., & Singerman, L. J. (2002) · Optometry and Vision Science · doi:10.1097/00006324-200204000-00008 · Cited by 23
Marshall, J. A. (2016) · Eye · doi:10.1038/eye.2015.265 · Cited by 18
Cited by
Digital Eye Strain- A Comprehensive Review
Kaur, K., Gurnani, B., Nayak, S., Deori, N., Kaur, S., Jethani, J., Singh, D., Agarkar, S., Hussaindeen, J. R., Sukhija, J., et al. (2022) · Ophthalmology and Therapy · doi:10.1007/s40123-022-00540-9 · Cited by 313
Mohan, A., Sen, P., Shah, C., Jain, E., & Jain, S. (2021) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_2535_20 · Cited by 277
A survey of E-learning methods in nursing and medical education during COVID-19 pandemic in India
Singh, H. K., Joshi, A., Malepati, R. N., Najeeb, S., Balakrishna, P., Pannerselvam, N. K., Singh, Y. K., & Ganne, P. (2021) · Nurse Education Today · doi:10.1016/j.nedt.2021.104796 · Cited by 161
“Screen time (all gadgets put together) of >4 h a day has shown to increase digital eye strain (manifested as headaches, blurred vision, dry eyes, and pain in the neck and shoulders) (Sheppard and Wolffsohn, 2018).”
BackgroundCampbell, I., Sharifpour, R., & Vandewalle, G. (2023) · Clocks & Sleep · doi:10.3390/clockssleep5010012 · Cited by 43
Remote Medical Education: Adapting Kern’s Curriculum Design to Tele-teaching
Said, J. T., & Schwartz, A. W. (2021) · Medical Science Educator · doi:10.1007/s40670-020-01186-7 · Cited by 38
Metadata
- Authors
- Sheppard, A. L., & Wolffsohn, J. S.
- Venue
- BMJ Open Ophthalmology
- Publisher
- BMJ
- Published
- 2018-04
- Volume
- 3
- Issue
- 1
- Pages
- e000146
- ISSN
- 2397-3269 (ISSN-L)
- OpenAlex
- W2800705505
- Cited by
- 731
- References
- 53
- FWCI
- 57.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.