Validity of the Fitbit activity tracker for measuring steps in community-dwelling older adults
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background: Commercially available activity monitors, such as the Fitbit, may encourage physical activity. However, the accuracy of the Fitbit in older adults remains unknown. This study aimed to determine (1) the criterion validity of Fitbit step counts compared to visual count and ActiGraph accelerometer step counts and (2) the accuracy of ActiGraph step counts compared to visual count in community-dwelling older people. Methods: Thirty-two community-dwelling adults aged over 60 wore Fitbit and ActiGraph devices simultaneously during a 2 min walk test (2MWT) and then during waking hours over a 7-day period. A physiotherapist counted the steps taken during the 2MWT. Results: There was excellent agreement between Fitbit and visually counted steps (intraclass correlation coefficient (ICC 2,1)=0.88, 95% CI 0.76 to 0.94) from the 2MWT, and good agreement between Fitbit and ActiGraph (ICC 2,1=0.66, 95% CI 0.41 to 0.82), and between ActiGraph and visually counted steps (ICC 2,1=0.60, 95% CI 0.33 to 0.79). There was excellent agreement between the Fitbit and ActiGraph in average steps/day over 7 days (ICC 2,1=0.94, 95% CI 0.88 to 0.97). Percentage agreement was closest for Fitbit steps compared to visual count (mean 0%, SD 4%) and least for Fitbit average steps/day compared to the ActiGraph (mean 13%, SD 25%). Conclusions: The Fitbit accurately tracked steps during the 2MWT, but the ActiGraph appeared to underestimate steps. There was strong agreement between Fitbit and ActiGraph counted steps. The Fitbit tracker is sufficiently accurate to be used among community-dwelling older adults to monitor and give feedback on step counts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Computing Inter-Rater Reliability for Observational Data: An Overview and Tutorial
Hallgren, K. A. (2012) · Tutorials in Quantitative Methods for Psychology · doi:10.20982/tqmp.08.1.p023 · Cited by 3,884 · cited 1×
“40 poor.(22) Percentage agreement for step counts against the criterion measure of visual count, or of the ActiGraph for Fitbit versus ActiGraph comparisons, were also calculated.”
MethodFit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
Sitting time and all-cause mortality risk in 222,497 Australian adults
van der Ploeg, H. P. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.2174 · Cited by 884
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654 · cited 1×
“…aimed to determine the criterion validity 18 (ie, accuracy) of a Fitbit tracker ’ s (One or Zip) step count compared to visual count by a health professional and to the well-validated ActiGraph GT3X+ accelerometer 19 (ActiGraph Corp, Pensacola, Florida, USA) in community-dwelling older adults.”
MethodLyons, E. J., Lewis, Z. H., Mayrsohn, B. G., & Rowland, J. L. (2014) · Journal of Medical Internet Research · doi:10.2196/jmir.3469 · Cited by 547 · cited 1×
“The Fitbit tracker is relatively affordable, simple to use and allows self-monitoring and goal setting by providing feedback on the device itself or through the internet interface.(24) The Fitbit’s internet interface also stores long-term physical activity levels.”
BackgroundPredicting peak kinematic and kinetic parameters from gait speed
Lelas, J. L., Merriman, G. J., Riley, P. O., & Kerrigan, D. C. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00060-7 · Cited by 430 · cited 1×
“16 The smaller leg accelerations generated during slower walking speeds 25 in people with gait alterations are unlikely to trigger recognition of a step in accelerometers due to the high thresholds used to detect movement in these devices; 26 however, this needs further investigation.”
BackgroundLee, I.-M., & Shiroma, E. J. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093154 · Cited by 415 · cited 1×
“The smaller leg accelerations generated during slower walking speeds(25) in people with gait alterations are unlikely to trigger recognition of a step in accelerometers due to the high thresholds used to detect movement in these devices;(26) however, this needs further investigation.(27) It was also observed that many…”
BackgroundFitbit®: An accurate and reliable device for wireless physical activity tracking
Diaz, K. M., Krupka, D. J., Chang, M. J., Peacock, J., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.03.038 · Cited by 405
Comparison of pedometer and accelerometer measures of free-living physical activity
TUDOR-LOCKE, C., AINSWORTH, B. E., THOMPSON, R. W., & MATTHEWS, C. E. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200212000-00027 · Cited by 386 · cited 1×
“16 The smaller leg accelerations generated during slower walking speeds 25 in people with gait alterations are unlikely to trigger recognition of a step in accelerometers due to the high thresholds used to detect movement in these devices; 26 however, this needs further investigation.”
Background
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
Human Physical Activity Recognition Using Smartphone Sensors
Voicu, R.-A., Dobre, C., Bajenaru, L., & Ciobanu, R.-I. (2019) · Sensors · doi:10.3390/s19030458 · Cited by 172
“These kinds of devices have started being used as components of more complex systems that employ many sensors to perform in-depth activity recognition for scenarios such as healthcare [19], healthy aging [20], persuasive technology for healthy behavior [21], etc.”
BackgroundSushames, A., Edwards, A., Thompson, F., McDermott, R., & Gebel, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161224 · Cited by 152
“[19] found excellent agreement in the average step count per day between the two devices recorded in free-living conditions and worn on the waist.”
BackgroundStraiton, N., Alharbi, M., Bauman, A., Neubeck, L., Gullick, J., Bhindi, R., & Gallagher, R. (2018) · Maturitas · doi:10.1016/j.maturitas.2018.03.016 · Cited by 147
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O'Flynn, B. (2019) · JMIR mHealth and uHealth · doi:10.2196/13084 · Cited by 139
“Also, this study confirms previous findings [17,18] indicating a slight overcounting by the Fitbit device and an undercounting by the ActiGraph.”
MethodResultCollins, J. E., Yang, H. Y., Trentadue, T. P., Gong, Y., & Losina, E. (2019) · PLOS ONE · doi:10.1371/journal.pone.0211231 · Cited by 55
Vetrovsky, T., Siranec, M., Marencakova, J., Tufano, J. J., Capek, V., Bunc, V., & Belohlavek, J. (2019) · PLOS ONE · doi:10.1371/journal.pone.0222569 · Cited by 53
Congruent Accuracy of Wrist-worn Activity Trackers during Controlled and Free-living Conditions
Dondzila, C. J., Lewis, C., Lopez, J. R., & Parker, T. (2018) · International Journal of Exercise Science · doi:10.70252/ubbt6886 · Cited by 16
“Older adults, however, were the target population in one study (9), who commonly demonstrate different gait patterns that influence activity tracker accuracy (21).”
BackgroundOccupational physical activity in brewery and office workers
Thompson, J. F., Severson, R. L., & Rosecrance, J. C. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1492136 · Cited by 9
“Steps Fitbit devices have been validated wearable devices for measuring steps under ideal conditions,([32,36,48,68,69])”
Method
Metadata
- Authors
- Paul, S. S., Tiedemann, A., Hassett, L. M., Ramsay, E., Kirkham, C., Chagpar, S., & Sherrington, C.
- Venue
- BMJ Open Sport & Exercise Medicine
- Publisher
- BMJ
- Published
- 2015-07
- Volume
- 1
- Issue
- 1
- Pages
- e000013
- ISSN
- 2055-7647 (ISSN-L)
- OpenAlex
- W2196551647
- Cited by
- 164
- References
- 28
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.