The DOI matches its Crossref record; 26 of the 28 references it cites were found in a registry or an index.
Diagnostic yield of an ambulatory patch monitor in patients with unexplained syncope after initial evaluation in the emergency department: the PATCH-ED study
Abstract
OBJECTIVES: Diagnosing underlying arrhythmia in ED syncope patients remains problematic. This study investigates diagnostic yield, event prevalence, patient satisfaction and compliance, and influence on resource utilisation of an ambulatory patch monitor in unexplained ED syncope patients. METHODS: Prospective pilot study conducted in a single tertiary ED in Scotland between 17 November 2015 and 16 June 2017 with a historical unmatched comparator group. Patients 16 years or over presenting within 6 hours of unexplained syncope were fitted in the ED with an ambulatory patch ECG recorder (Zio XT monitor), which continuously records a single-lead ECG for up to 14 days. Patients with an obvious underlying cause were excluded. An unmatched historical group of 603 syncope patients with no obvious diagnosis in ED, recruited to a prior cohort study (2007-2008), were used as a comparator. Primary endpoint was symptomatic significant arrhythmia at 90-day follow-up. RESULTS: During the prospective study period, 86 patients were recruited. 90-day diagnostic yield for symptomatic significant arrhythmia was 10.5% (95% CI 4.0 to 16.9; 9 of 86) versus 2.0% (95% CI 0.9 to 3.1; 12 of 603) in the comparator group. 24 patients (27.9%) had a significant arrhythmia (five serious); 26 patients (30.2%) had serious outcomes (major adverse cardiac event and/or death). Blinded patch report review suggested the patch would significantly reduce requirement for standard outpatient ambulatory ECG monitoring. 56 of 76 returned patches had a diagnostic finding within±45 s of a triggered/diary event (73.7% diagnostic utility; 95% CI 63.7 to 83.6); 34 of 56 (61%) for sinus rhythm or ectopic beats only. CONCLUSIONS: Routine, early ambulatory ECG monitoring in ED patients with unexplained syncope is probably warranted. A large-scale trial comparing this approach to standard care with cost-effectiveness and safety analysis is now required. TRIAL REGISTRATION: NCT02683174.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Third universal definition of myocardial infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., White, H. D., the Writing Group on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction, Authors/Task Force Members Chairpersons, Thygesen, K., Alpert, J. S., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs184 · Cited by 3,058
Third universal definition of myocardial infarction
the Writing Group on behalf of the Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction, Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., & White, H. D. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2012.122 · Cited by 2,053
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Self-citationBarrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
The ROSE (Risk Stratification of Syncope in the Emergency Department) Study
Reed, M. J., Newby, D. E., Coull, A. J., Prescott, R. J., Jacques, K. G., & Gray, A. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.049 · Cited by 272
Self-citationIncremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope
Gibson, T. C., & Heitzman, M. R. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90628-3 · Cited by 229
Cited by
Lampert, R., Chung, E. H., Ackerman, M. J., Arroyo, A. R., Darden, D., Deo, R., Dolan, J., Etheridge, S. P., Gray, B. R., Harmon, K. G., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.05.018 · Cited by 167
Smart Wearables for Cardiac Monitoring—Real-World Use beyond Atrial Fibrillation
Duncker, D., Ding, W. Y., Etheridge, S. P., Noseworthy, P. A., Veltmann, C., Yao, X., Bunch, T. J., & Gupta, D. (2021) · Sensors · doi:10.3390/s21072539 · Cited by 157
“Similar application in patients with unexplained syncope who presented to the emergency department resulted in a diagnostic yield of 27.9% [12].”
BackgroundInfluentialThe Use of Wearable ECG Devices in the Clinical Setting: A Review
Kamga, P., Mostafa, R., & Zafar, S. (2022) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-022-00248-x · Cited by 94
Bouzid, Z., Al‐Zaiti, S. S., Bond, R., & Sejdić, E. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.02.030 · Cited by 115
Yenikomshian, M. A., Jarvis, J. L., Patton, C., Yee, C. W., Mortimer, R., Birnbaum, H. G., & Topash, M. (2019) · Current Medical Research and Opinion · doi:10.1080/03007995.2019.1610370 · Cited by 61
Metadata
- Authors
- Reed, M. J., Grubb, N. R., Lang, C. C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J.
- Affiliations
- Edinburgh Royal Infirmary (GB)
- University of Edinburgh (GB)
- Corresponding author
- Reed, Matthew J
- Venue
- Emergency Medicine Journal
- Publisher
- BMJ
- Published
- 2018-06-19
- Volume
- 35
- Issue
- 8
- Pages
- 477-485
- ISSN
- 1351-0622 (ISSN-L)
- 1472-0205
- 1472-0213
- OpenAlex
- W2808746119
- Cited by
- 28
- References
- 28
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 4 · 2021: 5 · 2020: 3 · 2019: 3 · 2018: 2
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Emergency Medicine Journal (publishedVersion)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- NHS Health Scotland
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- unexplained syncope, arrhythmia diagnosis, emergency department, diagnostic yield, major adverse cardiac events, medication adherence, resource utilization (health care)
- MeSH terms
- Aged, Emergency Service, Hospital, Female, Humans, Male, Middle Aged, Patient Compliance, Pilot Projects, Prospective Studies, Scotland, Syncope, Electrocardiography, Ambulatory, Patient Satisfaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic yield of an ambulatory patch monitor in patients with unexplained syncope after initial evaluation in the emergency department: the PATCH-ED study. https://app.cochat.ai/papers/10.1136/emermed-2018-207570
- The paper
- Reed, M. J., Grubb, N. R., Lang, C. C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J. (2018). Diagnostic yield of an ambulatory patch monitor in patients with unexplained syncope after initial evaluation in the emergency department: the PATCH-ED study. Emergency Medicine Journal. https://doi.org/10.1136/emermed-2018-207570
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.