Standard pulse oximeters can be used to monitor respiratory rate
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: One of the most important limitations of standard pulse oximeters is the inability to detect changes in respiratory rate until oxygenation is affected. This study sought to determine if analysis of the plethysmogram by wavelet transforms would enable the determination of changes in respiratory rate at an earlier stage. METHODS: Ten healthy adult volunteers were monitored, breathing at baseline and predetermined respiratory rates, using a standard pulse oximeter. Photo-plethysmograms captured in an attached lap top computer were then analysed using wavelet transforms. RESULTS: Determination of baseline respiratory rate and subsequent changes including apnoea were easily identified. COMMENT: Wavelet transforms permit the accurate determination of respiratory rate by a standard pulse oximeter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Respiration rate monitoring methods: A review
AL‐Khalidi, F. Q., Saatchi, R., Burke, D., Elphick, H., & Tan, S. (2011) · Pediatric Pulmonology · doi:10.1002/ppul.21416 · Cited by 536
Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613124 · Cited by 387
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Monte-Moreno, E. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.05.001 · Cited by 311
Addison, P. S., Watson, J. N., Mestek, M. L., & Mecca, R. S. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9332-y · Cited by 97
“Technical solutions to their measurement include: inspection of the respiratory oscillations in the filtered PPG [7, 9, 16–19]; frequency spectra-based approaches [10, 21] independent component analysis [22] Short-Time Fourier Analysis (STFT) [20]; neural networks [8]; variable frequency complex demodulation methods (…”
MethodSelf-citationMedical Devices for Measuring Respiratory Rate in Children: a Review
Daw, W. (2016) · Journal of Advances in Biomedical Engineering and Technology · doi:10.15379/2409-3394.2016.03.01.04 · Cited by 35
“[22] described using pulse oximeters in 10 healthy adults to extract respiratory waveforms to determine respiratory rates.”
Metadata
- Authors
- Leonard, P.
- Venue
- Emergency Medicine Journal
- Publisher
- BMJ
- Published
- 2003-11-01
- Volume
- 20
- Issue
- 6
- Pages
- 524-525
- ISSN
- 1351-0622 (ISSN-L)
- 1472-0205
- 1472-0213
- OpenAlex
- W2146407930
- Cited by
- 97
- References
- 0
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.