Prosthesis-patient mismatch: definition, clinical impact, and prevention
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Prosthesis-patient mismatch (PPM) is present when the effective orifice area of the inserted prosthetic valve is too small in relation to body size. Its main haemodynamic consequence is to generate higher than expected gradients through normally functioning prosthetic valves. This review updates the present knowledge about the impact of PPM on clinical outcomes. PPM is common (20–70% of aortic valve replacements) and has been shown to be associated with worse haemodynamic function, less regression of left ventricular hypertrophy, more cardiac events, and lower survival. Moreover, as opposed to most other risk factors, PPM can largely be prevented by using a prospective strategy at the time of operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The problem of valve prosthesis-patient mismatch.
Rahimtoola, S. H. (1978) · Circulation · doi:10.1161/01.cir.58.1.20 · Cited by 853
Acquired von Willebrand Syndrome in Aortic Stenosis
Vincentelli, A., Susen, S., Le Tourneau, T., Six, I., Fabre, O., Juthier, F., Bauters, A., Decoene, C., Goudemand, J., Prat, A., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022831 · Cited by 846
Pibarot, P., & Dumesnil, J. G. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00859-7 · Cited by 674
Self-citationMarcus, M. L., Doty, D. B., Hiratzka, L. F., Wright, C. B., & Eastham, C. L. (1982) · New England Journal of Medicine · doi:10.1056/nejm198211253072202 · Cited by 580
Impact of Valve Prosthesis-Patient Mismatch on Short-Term Mortality After Aortic Valve Replacement
Blais, C., Dumesnil, J. G., Baillot, R., Simard, S., Doyle, D., & Pibarot, P. (2003) · Circulation · doi:10.1161/01.cir.0000085167.67105.32 · Cited by 564
Self-citationConnolly, H. M., Oh, J. K., Schaff, H. V., Roger, V. L., Osborn, S. L., Hodge, D. O., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.101.16.1940 · Cited by 356
Dumesnil, J. G., Honos, G. N., Lemieux, M., & Beauchemin, J. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90355-s · Cited by 246
Self-citationProsthesis size and long-term survival after aortic valve replacement
Blackstone, E. H., Cosgrove, D. M., Jamieson, W. R. E., Birkmeyer, N. J., Lemmer, J. H., Miller, D. C., Butchart, E. G., Rizzoli, G., Yacoub, M., & Chai, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(03)00591-9 · Cited by 238
Time course of regression of left ventricular hypertrophy after aortic valve replacement.
Monrad, E. S., Hess, O. M., Murakami, T., Nonogi, H., Corin, W. J., & Krayenbuehl, H. P. (1988) · Circulation · doi:10.1161/01.cir.77.6.1345 · Cited by 236
Tasca, G., Mhagna, Z., Perotti, S., Centurini, P. B., Sabatini, T., Amaducci, A., Brunelli, F., Cirillo, M., Tomba, M. D., Quiani, E., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.587022 · Cited by 223
Self-citation
Cited by
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
The Role of Stress Echocardiography in Valvular Heart Disease: A Current Appraisal
Gentry III, J. L., Phelan, D., Desai, M. Y., & Griffin, B. P. (2017) · Cardiology · doi:10.1159/000460274 · Cited by 2,725
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
Self-citation2014 AHA/ACC guideline for the management of patients with valvular heart disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2014.05.014 · Cited by 989
Hachicha, Z., Dumesnil, J. G., Bogaty, P., & Pibarot, P. (2007) · Circulation · doi:10.1161/circulationaha.106.668681 · Cited by 959
Self-citationTranscatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923
Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Pibarot, P., & Dumesnil, J. G. (2009) · Circulation · doi:10.1161/circulationaha.108.778886 · Cited by 786
Self-citationHockaday, L. A., Kang, K. H., Colangelo, N. W., Cheung, P. Y. C., Duan, B., Malone, E., Wu, J., Girardi, L. N., Bonassar, L. J., Lipson, H., et al. (2012) · Biofabrication · doi:10.1088/1758-5082/4/3/035005 · Cited by 683
Head, S. J., Mokhles, M. M., Osnabrugge, R. L. J., Pibarot, P., Mack, M. J., Takkenberg, J. J. M., Bogers, A. J. J. C., & Kappetein, A. P. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs003 · Cited by 522
Self-citationAbdel-Wahab, M., Zahn, R., Horack, M., Gerckens, U., Schuler, G., Sievert, H., Eggebrecht, H., Senges, J., Richardt, G., & for the German transcatheter aortic valve interventions registry investigators (2011) · Heart · doi:10.1136/hrt.2010.217158 · Cited by 474
Clavel, M.-A., Webb, J. G., Pibarot, P., Altwegg, L., Dumont, E., Thompson, C., De Larochellière, R., Doyle, D., Masson, J.-B., Bergeron, S., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.01.060 · Cited by 389
Self-citationDeterminants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
Détaint, D., Lepage, L., Himbert, D., Brochet, E., Messika-Zeitoun, D., Iung, B., & Vahanian, A. (2009) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2009.07.003 · Cited by 386
Mechanical versus bioprosthetic aortic valve replacement
Head, S. J., Çelik, M., & Kappetein, A. P. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx141 · Cited by 363
Dumesnil, J. G., Pibarot, P., & Carabello, B. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp361 · Cited by 329
Self-citationThe Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement
Fallon, J. M., DeSimone, J. P., Brennan, J. M., O’Brien, S., Thibault, D. P., DiScipio, A. W., Pibarot, P., Jacobs, J. P., & Malenka, D. J. (2018) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.01.090 · Cited by 257
Self-citationImpact of Prosthesis-Patient Mismatch on Long-Term Survival After Aortic Valve Replacement
Mohty, D., Dumesnil, J. G., Echahidi, N., Mathieu, P., Dagenais, F., Voisine, P., & Pibarot, P. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.09.022 · Cited by 255
Self-citationAortic Valve and Ascending Aorta Guidelines for Management and Quality Measures
Svensson, L. G., Adams, D. H., Bonow, R. O., Kouchoukos, N. T., Miller, D. C., O'Gara, P. T., Shahian, D. M., Schaff, H. V., Akins, C. W., Bavaria, J. E., et al. (2013) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2013.01.083 · Cited by 215
Zoghbi, W. A., Jone, P.-N., Chamsi-Pasha, M. A., Chen, T., Collins, K. A., Desai, M. Y., Grayburn, P., Groves, D. W., Hahn, R. T., Little, S. H., et al. (2024) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2023.10.004 · Cited by 197
Aortic Stenosis and Small Aortic Annulus: Clinical Challenges and Current Therapeutic Alternatives
Freitas-Ferraz, A. B., Tirado-Conte, G., Dagenais, F., Ruel, M., Al-Atassi, T., Dumont, E., Mohammadi, S., Bernier, M., Pibarot, P., & Rodés-Cabau, J. (2019) · Circulation · doi:10.1161/circulationaha.118.038408 · Cited by 159
Self-citationSpringhetti, P., Abdoun, K., & Clavel, M.-A. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13144237 · Cited by 24
“PPM after AVR occurs when the effective orifice area (EOA) is too small for the patient’s cardiovascular requirements [175,176]. updated, lowering the threshold for patients with a body mass index (BMI) above 30 kg/m 2 (VARC 3 Definition) [181,182], which Severe PPM after SAVR occurs in 11% of…”
Background
Metadata
- Authors
- Pibarot, P., & Dumesnil, J. G.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2005-10-26
- Volume
- 92
- Issue
- 8
- Pages
- 1022-1029
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2038851398
- Cited by
- 606
- References
- 25
- FWCI
- 8.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.