Effect of erythropoietin as an adjunct to primary percutaneous coronary intervention: a randomised controlled clinical trial
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: The acute administration of high-dose erythropoietin (EPO) on reperfusing ischaemic myocardium has been reported to halve myocardial infarct (MI) size in preclinical studies, but its effect in ST elevation myocardial infarction patients undergoing primary percutaneous coronary intervention (PPCI) remains unknown. We investigated whether high-dose EPO administered as an adjunct to PPCI reduces MI size. Design: Double-blinded, randomised, placebo-controlled. Setting: Single tertiary cardiac centre. Patients: Fifty-one ST elevation myocardial infarction patients undergoing PPCI. Interventions: Patients were randomly assigned to receive either a single intravenous bolus of EPO (50 000 IU) prior to PPCI with a further bolus given 24 h later (n=26) or placebo (n=25). Main outcome measures: MI size measured by 24 h area under the curve troponin T and cardiac magnetic resonance imaging performed on day 2 and at 4 months. Results: EPO treatment failed to reduce MI size (troponin T area under the curve: 114.6±78 μg/ml EPO vs 100.8±68 μg/ml placebo; infarct mass by cardiac magnetic resonance: 33±16 g EPO vs 25±16 g placebo; both p>0.05). Unexpectedly, EPO treatment doubled the incidence of microvascular obstruction (82% EPO vs 47% placebo; p=0.02) and significantly increased indexed left ventricular (LV) end-diastolic volumes (84±10 ml/m 2 EPO vs 73±13 ml/m 2 placebo; p=0.003), indexed LV end-systolic volumes (41±9 ml/m 2 EPO vs 35±11 ml/m 2 placebo; p=0.035) and indexed myocardial mass (89±16 g/m 2 EPO vs 79±11 g/m 2 placebo; p=0.03). At 4 months, there were no significant differences between groups. Conclusions: High-dose EPO administered as an adjunct to PPCI failed to reduce MI size. In fact, EPO treatment was associated with an increased incidence of microvascular obstruction, LV dilatation and increased LV mass. Clinical Trial Registration Information: http://public.ukcrn.org.uk/search/StudyDetail.aspx?StudyID=4058 Unique Identifier=Study ID 4058.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yellon, D. M., & Hausenloy, D. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra071667 · Cited by 3,797
Self-citationRecombinant Human Erythropoietin in the Treatment of Acute Ischemic Stroke
Ehrenreich, H., Weissenborn, K., Prange, H., Schneider, D., Weimar, C., Wartenberg, K., Schellinger, P. D., Bohn, M., Becker, H., Wegrzyn, M., et al. (2009) · Stroke · doi:10.1161/strokeaha.109.564872 · Cited by 605
Ott, I., Schulz, S., Mehilli, J., Fichtner, S., Hadamitzky, M., Hoppe, K., Ibrahim, T., Martinoff, S., Massberg, S., Laugwitz, K.-L., et al. (2010) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.109.904425 · Cited by 128
Cited by
Myocardial ischemia-reperfusion injury: a neglected therapeutic target
Hausenloy, D. J., & Yellon, D. M. (2013) · Journal of Clinical Investigation · doi:10.1172/jci62874 · Cited by 2,357
“prior to PPCI, No difference in MI size at 3 days using CMR and Trop-T; 2011 (115) repeated after 24 hours 2-fold higher incidence of MVO on CMR Exenatide”
Self-citationIschaemic conditioning and targeting reperfusion injury: a 30 year voyage of discovery
Hausenloy, D. J., Barrabes, J. A., Bøtker, H. E., Davidson, S. M., Di Lisa, F., Downey, J., Engstrom, T., Ferdinandy, P., Carbrera-Fuentes, H. A., Heusch, G., et al. (2016) · Basic Research in Cardiology · doi:10.1007/s00395-016-0588-8 · Cited by 308
Self-citationCoronary microvascular obstruction: the new frontier in cardioprotection
Heusch, G. (2019) · Basic Research in Cardiology · doi:10.1007/s00395-019-0756-8 · Cited by 253
Hausenloy, D. J., Bøtker, H. E., Condorelli, G., Ferdinandy, P., Garcia-Dorado, D., Heusch, G., Lecour, S., van Laake, L. W., Madonna, R., Ruiz-Meana, M., et al. (2013) · Cardiovascular Research · doi:10.1093/cvr/cvt004 · Cited by 228
Self-citationCardioprotection during cardiac surgery.
Hausenloy, D. J., Boston-Griffiths, E., & Yellon, D. M. (2012) · Cardiovascular Research · doi:10.1093/cvr/cvs131 · Cited by 152
Self-citation
Metadata
- Authors
- Ludman, A. J., Yellon, D. M., Hasleton, J., Ariti, C., Babu, G. G., Boston-Griffiths, E., Venugopal, V., Walker, M., Holdright, D., Swanton, H., Crake, T., Brull, D., Moon, J. C., Puranik, R., Mutharangu, V., Taylor, A., & Hausenloy, D. J.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2011-09-07
- Volume
- 97
- Issue
- 19
- Pages
- 1560-1565
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2122359402
- Cited by
- 76
- References
- 3
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.