Cited by 252Electronic Health Records SystemsHealthcare Technology and Patient MonitoringClinical Laboratory Practices and Quality Control

Improving Response to Critical Laboratory Results with Automation: Results of a Randomized Controlled Trial

Open access
Kuperman, G. J., Teich, J. M., Tanasijevic, M. J., Ma'Luf, N., Rittenberg, E., Jha, A., Fiskio, J., Winkelman, J. +1 more·1999·Journal of the American Medical Informatics Association

Abstract

OBJECTIVE: To evaluate the effect of an automatic alerting system on the time until treatment is ordered for patients with critical laboratory results. DESIGN: Prospective randomized controlled trial. INTERVENTION: A computer system to detect critical conditions and automatically notify the responsible physician via the hospital's paging system. PATIENTS: Medical and surgical inpatients at a large academic medical center. One two-month study period for each service. MAIN OUTCOMES: Interval from when a critical result was available for review until an appropriate treatment was ordered. Secondary outcomes were the time until the critical condition resolved and the frequency of adverse events. METHODS: The alerting system looked for 12 conditions involving laboratory results and medications. For intervention patients, the covering physician was automatically notified about the presence of the results. For control patients, no automatic notification was made. Chart review was performed to determine the outcomes. RESULTS: After exclusions, 192 alerting situations (94 interventions, 98 controls) were analyzed. The intervention group had a 38 percent shorter median time interval (1.0 hours vs. 1.6 hours, P = 0.003; mean, 4.1 vs. 4.6 hours, P = 0.003) until an appropriate treatment was ordered. The time until the alerting condition resolved was less in the intervention group (median, 8.4 hours vs. 8.9 hours, P = 0.11; mean, 14.4 hours vs. 20.2 hours, P = 0.11), although these results did not achieve statistical significance. The impact of the intervention was more pronounced for alerts that did not meet the laboratory's critical reporting criteria. There was no significant difference between the two groups in the number of adverse events. CONCLUSION: An automatic alerting system reduced the time until an appropriate treatment was ordered for patients who had critical laboratory results. Information technologies that facilitate the transmission of important patient data can potentially improve the quality of care.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jamia.1999.0060512

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A sample size of 30 participants, each reviewing 35 test results, was required to achieve 80% power to detect a statistically significant difference in cognitive workload and performance.

    “On the basis of the anticipated rate of appropriately identified abnormal test results in the literature12,13,14,15,16,17,18,19,20,21 and the anticipated magnitude of the association of the enhanced EHR, we required a sample size of 30 participants, each reviewing 35 test results, to achieve 80% power to detect a statistically significant difference in cognitive workload and performance.”

    From Association of the Usability of Electronic Health Records With Cognitive Workload and Performance Levels Among Physicians (2019) · cites this paper as [12]

    The Results report rates of physician review and intended action for critical-result alerts, which can inform the cited background about responses to abnormal results. The Analysis also mentions 80% power, but for detecting reductions in time to treatment and resolution—not for a study of 30 participants reviewing 35 results or for cognitive workload and performance. Those sample-size and outcome details are not supported by this source. (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • Even in the EHR environment, with alerts and reminders in place, physicians continue to often inappropriately manage abnormal test results.

    “Even in the EHR environment, with alerts and reminders in place, physicians continue to often inappropriately manage abnormal test results.12,13,14,15,16,17,18,19,20,21”

    From Association of the Usability of Electronic Health Records With Cognitive Workload and Performance Levels Among Physicians (2019) · cites this paper as [12]

    The Results (page unavailable) show that even with automated alerts, treatment was ordered more than five hours later in 16% of intervention cases. This supports persistent delays for some critical laboratory results, but the paper does not establish that physicians often managed abnormal results inappropriately across EHR settings; its principal finding was that alerts shortened the time to treatment. (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • Electronic alerts show promise in improving the safety of outpatient test result follow-up.

    “Electronic “alerts” have been shown to improve critical lab results communication in the inpatient setting, and they show promise in improving the safety of outpatient test result follow-up.45,52,53”
  • Electronic alerts have been shown to improve critical lab results communication in the inpatient setting.

    “Electronic “alerts” have been shown to improve critical lab results communication in the inpatient setting, and they show promise in improving the safety of outpatient test result follow-up.45,52,53”
  • Achieving high standards of patient safety through the use of IT also entails system redesign to include formal policies and procedures regarding the use of IT.

    “Thus, achieving high standards of patient safety through the use of IT also entails system redesign to include formal policies and procedures regarding the use of IT.43–47”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 33 references couldn’t be matched to a known paper.

Research works printed but not linked: 5

  1. Tate KE, Gardner RM, Weaver LK. A computerized labo- ratory alerting system. MD Comput. 1990;7(5):296-301.
  2. McDonald CJ. Computer reminders, the quality of care, and the nonperfectability of man. N Engl J Med. 1976;295: 1351-5.
  3. Leape LL, Bates DW, Cullen DJ, et al. Systems analysis of adverse drug events. ADE Prevention Study Group. JAMA. 1995;274(1):35-43.
  4. Teich JM, Glaser JP, Beckley RF, et al. Toward cost-effective, quality care: The Brigham Integrated Computing System. In: Steen EB (ed). Proceedings of the 2nd Nicholas E. Davies CPR Recognition Symposium. Washington DC: Computer- ized Patient Record Institute, 1996:3-34.
  5. Petersen LA, Orav EJ, Teich JM, O'Neil AC, Brennan TA. Using a computerized signout to improve continuity of in- patient care and prevent adverse events. Jt Comm J Qual Improv. 1998;24(2):77-87.

Cited by

Sorted by citations

Authors
Kuperman, G. J., Teich, J. M., Tanasijevic, M. J., Ma'Luf, N., Rittenberg, E., Jha, A., Fiskio, J., Winkelman, J., & Bates, D. W.
Affiliations
Harvard University (US)
Corresponding author
Kuperman, G. J.
Venue
Journal of the American Medical Informatics Association
Published
1999-11-01
Volume
6
Issue
6
Pages
512-522
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W1961197524
Cited by
252
References
33
Citations by year
2026: 3 · 2025: 3 · 2024: 2 · 2023: 3 · 2022: 5 · 2021: 5 · 2020: 7 · 2019: 9 · 2018: 8 · 2017: 6 · 2016: 9 · 2015: 6 · 2014: 11 · 2013: 10 · 2012: 11
FWCI
18.24
Type
journal article
Language
en
Open access
Locations
  • Journal of the American Medical Informatics Association (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Agency for Healthcare Research and Quality (R01-HS08927)
Topics
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
automated alerts, physician notification, critical value reporting, adverse events, hospitalized patients, health information technology, quality of care
MeSH terms
Academic Medical Centers, Electronic Data Processing, Clinical Laboratory Information Systems, Hospital Communication Systems, Humans, Prospective Studies, Software, Therapy, Computer-Assisted, Time Factors, Point-of-Care Systems, Clinical Laboratory Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review