CoChat

Laboratory assessment of vitamin B12 status

Harrington, Dominic J · 2017 · Journal of Clinical Pathology
Cited by 130

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The detection and correction of vitamin B 12 (B 12) deficiency prevents megaloblastic anaemia and potentially irreversible neuropathy and neuropsychiatric changes. B 12 status is commonly estimated using the abundance of the vitamin in serum, with ∼148 pmol/L (200 ng/L) typically set as the threshold for diagnosing deficiency. Serum B 12 assays measure the sum of haptocorrin-bound and transcobalamin-bound (known as holotranscobalamin) B 12. It is only holotranscobalamin that is taken up by cells to meet metabolic demand. Although receiver operator characteristic curves show holotranscobalamin measurement to be a moderately more reliable marker of B 12 status than serum B 12, both assays have an indeterminate range. Biochemical evidence of metabolic abnormalities consistent with B 12 insufficiency is frequently detected despite an apparently sufficient abundance of the vitamin. Laboratory B 12 status markers that reflect cellular utilisation rather than abundance are available. Two forms of B 12 act as coenzymes for two different reactions. Methionine synthase requires methylcobalamin for the remethylation of methionine from homocysteine. A homocysteine concentration >20 µmol/L may suggest B 12 deficiency in folate-replete patients. In the second B 12-dependent reaction, methylmalonyl-CoA mutase uses adenosylcobalamin to convert methylmalonyl-CoA to succinyl-CoA. In B 12 deficiency excess methylmalonyl-CoA is hydrolysed to methylmalonic acid. A serum concentration >280 nmol/L may suggest suboptimal status in young patients with normal renal function. No single laboratory marker is suitable for the assessment of B 12 status in all patients. Sequential assay selection algorithms or the combination of multiple markers into a single diagnostic indicator are both approaches that can be used to mitigate inherent limitations of each marker when used independently.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jclinpath-2015-203502

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 130

Metadata

Authors
Harrington, D. J.
Venue
Journal of Clinical Pathology
Publisher
BMJ
Published
2016-05-11
Volume
70
Issue
2
Pages
168-173
ISSN
  • 0021-9746 (ISSN-L)
  • 1472-4146
OpenAlex
W2351559594
Cited by
130
References
7
FWCI
7.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.