Artificial intelligence to diagnose ischemic stroke and identify large vessel occlusions: a systematic review
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Background and purpose: Acute stroke caused by large vessel occlusions (LVOs) requires emergent detection and treatment by endovascular thrombectomy. However, radiologic LVO detection and treatment is subject to variable delays and human expertise, resulting in morbidity. Imaging software using artificial intelligence (AI) and machine learning (ML), a branch of AI, may improve rapid frontline detection of LVO strokes. This report is a systematic review of AI in acute LVO stroke identification and triage, and characterizes LVO detection software. Methods: A systematic review of acute stroke diagnostic-focused AI studies from January 2014 to February 2019 in PubMed, Medline, and Embase using terms: ‘artificial intelligence’ or ‘machine learning or deep learning’ and ‘ischemic stroke’ or ‘large vessel occlusion’ was performed. Results: Variations of AI, including ML methods of random forest learning (RFL) and convolutional neural networks (CNNs), are used to detect LVO strokes. Twenty studies were identified that use ML. Alberta Stroke Program Early CT Score (ASPECTS) commonly used RFL, while LVO detection typically used CNNs. Image feature detection had greater sensitivity with CNN than with RFL, 85% versus 68%. However, AI algorithm performance metrics use different standards, precluding ideal objective comparison. Four current software platforms incorporate ML: Brainomix (greatest validation of AI for ASPECTS, uses CNNs to automatically detect LVOs), General Electric, iSchemaView (largest number of perfusion study validations for thrombectomy), and Viz.ai (uses CNNs to automatically detect LVOs, then automatically activates emergency stroke treatment systems). Conclusions: AI may improve LVO stroke detection and rapid triage necessary for expedited treatment. Standardization of performance assessment is needed in future studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goyal, M., Menon, B. K., van Zwam, W. H., Dippel, D. W. J., Mitchell, P. J., Demchuk, A. M., Dávalos, A., Majoie, C. B. L. M., van der Lugt, A., de Miquel, M. A., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00163-x · Cited by 7,815
Endovascular Therapy for Ischemic Stroke with Perfusion-Imaging Selection
Campbell, B. C. V., Mitchell, P. J., Kleinig, T. J., Dewey, H. M., Churilov, L., Yassi, N., Yan, B., Dowling, R. J., Parsons, M. W., Oxley, T. J., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1414792 · Cited by 5,819
Thrombectomy 6 to 24 Hours after Stroke with a Mismatch between Deficit and Infarct
Nogueira, R. G., Jadhav, A. P., Haussen, D. C., Bonafe, A., Budzik, R. F., Bhuva, P., Yavagal, D. R., Ribo, M., Cognard, C., Hanel, R. A., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1706442 · Cited by 5,629
Stent-Retriever Thrombectomy after Intravenous t-PA vs. t-PA Alone in Stroke
Saver, J. L., Goyal, M., Bonafe, A., Diener, H.-C., Levy, E. I., Pereira, V. M., Albers, G. W., Cognard, C., Cohen, D. J., Hacke, W., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1415061 · Cited by 5,193
Thrombectomy for Stroke at 6 to 16 Hours with Selection by Perfusion Imaging
Albers, G. W., Marks, M. P., Kemp, S., Christensen, S., Tsai, J. P., Ortega-Gutierrez, S., McTaggart, R. A., Torbey, M. T., Kim-Tenser, M., Leslie-Mazwi, T., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1713973 · Cited by 4,930
Orrù, G., Pettersson-Yeo, W., Marquand, A. F., Sartori, G., & Mechelli, A. (2012) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2012.01.004 · Cited by 1,012
del Zoppo, G. J., Saver, J. L., Jauch, E. C., & Adams, H. P. (2009) · Stroke · doi:10.1161/strokeaha.109.192535 · Cited by 829
Lansberg, M. G., Straka, M., Kemp, S., Mlynash, M., Wechsler, L. R., Jovin, T. G., Wilder, M. J., Lutsep, H. L., Czartoski, T. J., Bernstein, R. A., et al. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70203-x · Cited by 784
Tan, I. Y. L., Demchuk, A. M., Hopyan, J., Zhang, L., Gladstone, D., Wong, K., Martin, M., Symons, S. P., Fox, A. J., & Aviv, R. I. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1408 · Cited by 735
Real‐time diffusion‐perfusion mismatch analysis in acute stroke
Straka, M., Albers, G. W., & Bammer, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22338 · Cited by 401
Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy
Austein, F., Riedel, C., Kerby, T., Meyne, J., Binder, A., Lindner, T., Huhndorf, M., Wodarg, F., & Jansen, O. (2016) · Stroke · doi:10.1161/strokeaha.116.013147 · Cited by 231
Machine learning for outcome prediction of acute ischemic stroke post intra-arterial therapy
Asadi, H., Dowling, R., Yan, B., & Mitchell, P. (2014) · PLoS ONE · doi:10.1371/journal.pone.0088225 · Cited by 218 · cited 1×
“21 34–36 For example, one study showed that AI led to an absolute increase of 7% accuracy in predicting a symptomatic intracerebral hemorrhage.”
BackgroundNagel, S., Sinha, D., Day, D., Reith, W., Chapot, R., Papanagiotou, P., Warburton, E. A., Guyler, P., Tysoe, S., Fassbender, K., et al. (2017) · International Journal of Stroke · doi:10.1177/1747493016681020 · Cited by 217
Prediction of stroke thrombolysis outcome using CT brain machine learning
Bentley, P., Ganesalingam, J., Carlton Jones, A. L., Mahady, K., Epton, S., Rinne, P., Sharma, P., Halse, O., Mehta, A., & Rueckert, D. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.02.003 · Cited by 184 · cited 1×
“37”
Time to endovascular reperfusion and degree of disability in acute stroke
Sheth, S. A., Jahan, R., Gralla, J., Pereira, V. M., Nogueira, R. G., Levy, E. I., Zaidat, O. O., Saver, J. L., & Trialists, F. T. S. (2015) · Annals of Neurology · doi:10.1002/ana.24474 · Cited by 184
Herweh, C., Ringleb, P. A., Rauch, G., Gerry, S., Behrens, L., Möhlenbruch, M., Gottorf, R., Richter, D., Schieber, S., & Nagel, S. (2016) · International Journal of Stroke · doi:10.1177/1747493016632244 · Cited by 161
Computed tomographic perfusion to Predict Response to Recanalization in ischemic stroke
Lansberg, M. G., Christensen, S., Kemp, S. M., Mlynash, M., Mishra, N. K., Federau, C., Tsai, J. P.-C., Kim, S., Nogueria, R. G., Jovin, T. G., et al. (2017) · Annals of Neurology · doi:10.1002/ana.24953 · Cited by 137
Automated Calculation of the Alberta Stroke Program Early CT Score: Feasibility and Reliability
Maegerlein, C., Fischer, J. C., Mönch, S., Berndt, M. T., Wunderlich, S., Seifert, C. L., Lehm, M., Boeckh‐Behrens, T., Zimmer, C., & Friedrich, B. (2019) · Radiology · doi:10.1148/radiol.2019181228 · Cited by 135
Kuang, H., Najm, M., Chakraborty, D., Maraj, N., Sohn, S., Goyal, M., Hill, M. D., Demchuk, A. M., Menon, B. K., & Qiu, W. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5889 · Cited by 125
3D convolutional neural networks applied to CT angiography in the detection of acute ischemic stroke
Öman, O., Mäkelä, T. O., Salli, E., Savolainen, S. E., & Kangasniemi, M. (2019) · European Radiology Experimental · doi:10.1186/s41747-019-0085-6 · Cited by 97
Guberina, N., Dietrich, U., Radbruch, A., et al. (2018) · Neuroradiology · doi:10.1007/s00234-018-2066-5 · Cited by 96
An automated detection method for the MCA dot sign of acute stroke in unenhanced CT
Takahashi, N., Lee, Y., Tsai, D., Matsuyama, E., Kinoshita, T., & Ishii, K. (2013) · Radiological Physics and Technology · doi:10.1007/s12194-013-0234-1 · Cited by 67
Goebel, J., Stenzel, E., Guberina, N., Wanke, I., Koehrmann, M., Kleinschnitz, C., Umutlu, L., Forsting, M., Mönninghoff, C., & Radbruch, A. (2018) · Neuroradiology · doi:10.1007/s00234-018-2098-x · Cited by 63
Olivé‐Gadea, M., Martins, N., Boned, S., Alba, J. A. C., Moreno, M. J., Muchada, M., Molina, C. A., Tomasello, A., Ribó, M., & Rubiera, M. (2018) · Journal of Neuroimaging · doi:10.1111/jon.12564 · Cited by 56
Chatterjee, A. R., Somayaji, N. R., & Kabakis, I. M. (2019) · Stroke · doi:10.1161/str.50.suppl_1.wmp16 · Cited by 52
Context-Aware Convolutional Neural Networks for Stroke Sign Detection in Non-contrast CT Scans
Lisowska, A., O’Neil, A. Q., Dilys, V., Daykin, M., Beveridge, E., Muir, K. W., McLaughlin, S., & Poole, I. (2017) · Communications in computer and information science · doi:10.1007/978-3-319-60964-5_43 · Cited by 43
Novel Prehospital Prediction Model of Large Vessel Occlusion Using Artificial Neural Network
Chen, Z., Zhang, R., Xu, F., Gong, X., Shi, F., Zhang, M., & Lou, M. (2018) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2018.00181 · Cited by 41
Lucas, C., Kemmling, A., Bouteldja, N., Aulmann, L. F., Mamlouk, A. M., & Heinrich, M. P. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00989 · Cited by 41
Thornhill, R. E., Lum, C., Jaberi, A., Stefanski, P., Torres, C. H., Momoli, F., Petrcich, W., & Dowlatshahi, D. (2014) · Academic Radiology · doi:10.1016/j.acra.2013.11.011 · Cited by 33
Abstract WP61: Automated Large Artery Occlusion Detection IN Stroke Imaging - ALADIN Study
Barreira, C., Bouslama, M., Haussen, D. C., Grossberg, J. A., Baxter, B., Devlin, T. G., Frankel, M., & Nogueira, R. G. (2018) · Stroke · doi:10.1161/str.49.suppl_1.wp61 · Cited by 28
Lesion Location-Based Prediction of Visual Field Improvement after Cerebral Infarction
Kim, B. J., Kim, Y., Kim, N., Kwon, S. U., Kim, S. J., Kim, J. S., & Kang, D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0143882 · Cited by 21
Cited by
How to improve access to medical imaging in low- and middle-income countries
Frija, G., Blažić, I., Frush, D. P., Hierath, M., Kawooya, M., Donoso-Bach, L., & Brkljačić, B. (2021) · eClinicalMedicine · doi:10.1016/j.eclinm.2021.101034 · Cited by 310
“Imaging is an integral and crucial part in stroke diagnosis and image-guided endovascular treatment, and AI has a role to determine the presence and extent of involvement of brain parenchyma [20,21].”
BackgroundArtificial Intelligence and Acute Stroke Imaging
Soun, J. E., Chow, D. S., Nagamine, M., Takhtawala, R. S., Filippi, C. G., Yu, W., & Chang, P. D. (2021) · American Journal of Neuroradiology · doi:10.3174/ajnr.a6883 · Cited by 272
Metabolome Changes in Cerebral Ischemia
Shin, T. H., Lee, D. Y., Basith, S., Manavalan, B., Paik, M. J., Rybinnik, I., Mouradian, M. M., Ahn, J. H., & Lee, G. (2020) · Cells · doi:10.3390/cells9071630 · Cited by 170
“Time is a decisive factor in the diagnosis and treatment of cerebral ischemia, and often referred to as “time is brain” [15,20,24,30].”
BackgroundA reimbursement framework for artificial intelligence in healthcare
Abràmoff, M. D., Roehrenbeck, C., Trujillo, S., Goldstein, J., Graves, A. S., Repka, M. X., & Silva III, E. “. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00621-w · Cited by 117
Artificial intelligence in emergency radiology: A review of applications and possibilities
Katzman, B. D., van der Pol, C. B., Soyer, P., & Patlas, M. N. (2023) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2022.07.005 · Cited by 97
Metadata
- Authors
- Murray, N. M., Unberath, M., Hager, G. D., & Hui, F. K.
- Venue
- Journal of NeuroInterventional Surgery
- Publisher
- BMJ
- Published
- 2019-10-08
- Volume
- 12
- Issue
- 2
- Pages
- 156-164
- ISSN
- 1759-8478 (ISSN-L)
- 1759-8486
- OpenAlex
- W2979307665
- Cited by
- 308
- References
- 31
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.