Review of deep learning algorithms for the automatic detection of intracranial hemorrhages on computed tomography head imaging
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
Artificial intelligence is a rapidly evolving field, with modern technological advances and the growth of electronic health data opening new possibilities in diagnostic radiology. In recent years, the performance of deep learning (DL) algorithms on various medical image tasks have continually improved. DL algorithms have been proposed as a tool to detect various forms of intracranial hemorrhage on non-contrast computed tomography (NCCT) of the head. In subtle, acute cases, the capacity for DL algorithm image interpretation support might improve the diagnostic yield of CT for detection of this time-critical condition, potentially expediting treatment where appropriate and improving patient outcomes. However, there are multiple challenges to DL algorithm implementation, such as the relative scarcity of labeled datasets, the difficulties in developing algorithms capable of volumetric medical image analysis, and the complex practicalities of deployment into clinical practice. This review examines the literature and the approaches taken in the development of DL algorithms for the detection of intracranial hemorrhage on NCCT head studies. Considerations in crafting such algorithms will be discussed, as well as challenges which must be overcome to ensure effective, dependable implementations as automated tools in a clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Several systematic reviews have been conducted to summarize the performance of recent AI-assisted tools in specific clinical settings”
From Randomized Controlled Trials of Artificial Intelligence in Clinical Practice: Systematic Review (2022) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Pan, S. J., & Yang, Q. (2010) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2009.191 · Cited by 23,387
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332 · cited 1×
“61 An alternative to this is over/undersampling of certain classes.”
BackgroundDermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362
Quo Vadis, Action Recognition? A New Model and the Kinetics Dataset
Carreira, J., & Zisserman, A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.502 · Cited by 9,570
Artificial intelligence in radiology
Hosny, A., Parmar, C., Quackenbush, J., Schwartz, L. H., & Aerts, H. J. W. L. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0016-5 · Cited by 3,803 · cited 2×
“23 In CT head analysis, this may involve image denoising, segmentation of regions of interest (ROIs), for example, skull stripping, and other feature extractions.”
BackgroundMethodDeep learning for computer vision: A brief review
Voulodimos, A., Doulamis, N., Doulamis, A., & Protopapadakis, E. (2018) · Computational Intelligence and Neuroscience · doi:10.1155/2018/7068349 · Cited by 3,403
A few useful things to know about machine learning
Domingos, P. (2012) · Communications of the ACM · doi:10.1145/2347736.2347755 · Cited by 3,326 · cited 1×
“42 An inadequately sized dataset increases the risk of overfitting by the model (further explored in the section on ‘Limited data availability’).”
BackgroundCan Spatiotemporal 3D CNNs Retrace the History of 2D CNNs and ImageNet?
Hara, K., Kataoka, H., & Satoh, Y. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00685 · Cited by 2,205
Generative adversarial network in medical imaging: A review
Yi, X., Walia, E., & Babyn, P. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101552 · Cited by 1,863 · cited 1×
“62 One attempts to generate realistic images, while the other functions as a discriminator to evaluate the resemblance between the generated and original image.”
BackgroundComputer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
Spontaneous intracerebral hemorrhage
Qureshi, A. I., Tuhrim, S., Broderick, J. P., Batjer, H. H., Hondo, H., & Hanley, D. F. (2001) · New England Journal of Medicine · doi:10.1056/nejm200105103441907 · Cited by 1,719
Deep learning algorithms for detection of critical findings in head CT scans: a retrospective study
Chilamkurthy, S., Ghosh, R., Tanamala, S., Biviji, M., Campeau, N. G., Venugopal, V. K., Mahajan, V., Rao, P., & Warier, P. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31645-3 · Cited by 1,020 · cited 5×
“26 30 Indeed, Lee et al 30 found that steps such as this had a greater impact on improving algo-rithm accuracy than the choice of underlying CNN architecture itself.”
BackgroundMethodResultInfluentialeD octor: machine learning and the future of medicine
Handelman, G. S., Kok, H. K., Chandra, R. V., Razavi, A. H., Lee, M. J., & Asadi, H. (2018) · Journal of Internal Medicine · doi:10.1111/joim.12822 · Cited by 956 · cited 1×
“18 Both approaches follow a typical workflow of data preprocessing followed by model training and prediction, 19 but fundamental differences between the two types have led to deepening interest in DL over traditional ML. Early CAD tools used traditional ML algorithms.”
MethodSelf-citationPark, S. H., & Han, K. (2018) · Radiology · doi:10.1148/radiol.2017171920 · Cited by 894
Intracerebral haemorrhage: current approaches to acute management
Cordonnier, C., Demchuk, A., Ziai, W., & Anderson, C. S. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31878-6 · Cited by 725
Handbook of Statistical Analysis and Data Mining Applications
(2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374765-5.x0001-0 · Cited by 700
Giger (2018) · doi:10.1016/j.jacr.2017.12.028 · Cited by 634
Huynh, B. Q., Li, H., & Giger, M. L. (2016) · Journal of Medical Imaging · doi:10.1117/1.jmi.3.3.034501 · Cited by 539 · cited 1×
“49 Nonethe-less, TL has been applied successfully in breast tumour diagnosis 50 51 and skin cancer classification.”
MethodKim, H.-E., Kim, H. H., Han, B.-K., Kim, K. H., Han, K., Nam, H., Lee, E. H., & Kim, E.-K. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30003-0 · Cited by 525
McDonald, R. J., Schwartz, K. M., Eckel, L. J., Diehn, F. E., Hunt, C. H., Bartholmai, B. J., Erickson, B. J., & Kallmes, D. F. (2015) · Academic Radiology · doi:10.1016/j.acra.2015.05.007 · Cited by 460
Kim, D. W., Jang, H. Y., Kim, K. W., Shin, Y., & Park, S. H. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2019.0025 · Cited by 459 · cited 1×
“65 In the context of intracranial hemorrhage detection, many studies used split-sample validation.”
MethodAutomated deep-neural-network surveillance of cranial images for acute neurologic events
Titano, J. J., Badgeley, M., Schefflein, J., Pain, M., Su, A., Cai, M., Swinburne, N., Zech, J., Kim, J., Bederson, J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0147-y · Cited by 458
Arbabshirani, M. R., Fornwalt, B. K., Mongelluzzo, G. J., Suever, J. D., Geise, B. D., Patel, A. A., & Moore, G. J. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0015-z · Cited by 443 · cited 16×
“This particularly concerns 3D CNNs, which are more computationally intensive than 2D CNNs. 34 Integration with clinical workflow environments such as PACS is also paramount.”
BackgroundMethodInfluentialLee, H., Yune, S., Mansouri, M., Kim, M., Tajmir, S. H., Guerrier, C. E., Ebert, S. A., Pomerantz, S. R., Romero, J. M., Kamalian, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0324-9 · Cited by 441 · cited 8×
“26 30 Indeed, Lee et al 30 found that steps such as this had a greater impact on improving algo-rithm accuracy than the choice of underlying CNN architecture itself.”
BackgroundMethodInfluentialHandelman, G. S., Kok, H. K., Chandra, R. V., Razavi, A. H., Huang, S., Brooks, M., Lee, M. J., & Asadi, H. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20224 · Cited by 406
Self-citationAntropova, N., Huynh, B. Q., & Giger, M. L. (2017) · Medical Physics · doi:10.1002/mp.12453 · Cited by 389 · cited 1×
“49 Nonethe-less, TL has been applied successfully in breast tumour diagnosis 50 51 and skin cancer classification.”
MethodModels Genesis: Generic Autodidactic Models for 3D Medical Image Analysis
Zhou, Z., Sodha, V., Rahman Siddiquee, M. M., Feng, R., Tajbakhsh, N., Gotway, M. B., & Liang, J. (2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-32251-9_42 · Cited by 327
(1977) · Radiology · doi:10.1148/124.3.812 · Cited by 318
Med3D: Transfer Learning for 3D Medical Image Analysis
Chen, S., Ma, K., & Zheng, Y. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1904.00625 · Cited by 317 · cited 2×
“59 Image-pretrained 3D CNNs have not yet been applied in the context of CT intracranial hemorrhage detection and represent an avenue for future research, given their potential to boost 3D CNN performance.”
MethodMurray, N. M., Unberath, M., Hager, G. D., & Hui, F. K. (2020) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2019-015135 · Cited by 308 · cited 1×
“16 17 In the context of the detection of intracranial hemorrhage, several challenges exist which affect the use of these automated systems as a clinical tool.”
MethodImplementing Machine Learning in Radiology Practice and Research
Kohli, M., Prevedello, L. M., Filice, R. W., & Geis, J. R. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.16.17224 · Cited by 301
Hybrid 3D/2D Convolutional Neural Network for Hemorrhage Evaluation on Head CT
Chang, P. D., Kuoy, E., Grinband, J., Weinberg, B. D., Thompson, M., Homo, R., Chen, J., Abcede, H., Shafie, M., Sugrue, L., et al. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5742 · Cited by 277 · cited 4×
“22 30 34 38 The latter studies provide the most useful information for evaluation, with test sets simulating real-world clinical populations.”
BackgroundMethodInfluentialKuo, W., Hӓne, C., Mukherjee, P., Malik, J., & Yuh, E. L. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1908021116 · Cited by 264 · cited 4×
“22 31 43 This enables slightly different CNN architectures, which incorporate a segmentation approach to the detection task.”
BackgroundMethodInfluentialCross, D. T., Tirschwell, D. L., Clark, M. A., Tuden, D., Derdeyn, C. P., Moran, C. J., & Dacey, R. G. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.99.5.0810 · Cited by 260
The future of radiology augmented with Artificial Intelligence: A strategy for success
Liew, C. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.03.019 · Cited by 257 · cited 1×
“77 Addressing these uncertainties is vital in facilitating the deployment of these innovations.”
BackgroundPrevedello, L. M., Erdal, B. S., Ryu, J. L., Little, K. J., Demirer, M., Qian, S., & White, R. D. (2017) · Radiology · doi:10.1148/radiol.2017162664 · Cited by 246 · cited 2×
“However, in comparison with the 2D CNN and joint CNN-RNN studies, 26 27 35 these implementations achieved a lower AUROC.”
BackgroundResultYe, H., Gao, F., Yin, Y., Guo, D., Zhao, P., Lu, Y., Wang, X., Bai, J., Cao, K., Song, Q., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06163-2 · Cited by 244
A large-scale hierarchical image database
Deng, J. (2009) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · Cited by 229
RADnet: Radiologist level accuracy using deep learning for hemorrhage detection in CT scans
Grewal, M., Srivastava, M. M., Kumar, P., & Varadarajan, S. (2018) · 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018) · doi:10.1109/isbi.2018.8363574 · Cited by 213
The Acute Management of Intracerebral Hemorrhage: A Clinical Review
Elliott, J., & Smith, M. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181d568c8 · Cited by 202
Diagnosis and Management of Acute Intracerebral Hemorrhage
Morotti, A., & Goldstein, J. N. (2016) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2016.06.010 · Cited by 188
Ker, J., Singh, S. P., Bai, Y., Rao, J., Lim, T., & Wang, L. (2019) · Sensors · doi:10.3390/s19092167 · Cited by 180 · cited 7×
“24 26 28 30 34 35 This involves image transformations such as horizontal flipping to ‘generate’ more images for the model to train on.”
BackgroundMethodInfluentialMartín Noguerol, T., Paulano-Godino, F., Martín-Valdivia, M. T., Menias, C. O., & Luna, A. (2019) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2019.05.047 · Cited by 175
Regulatory responses to medical machine learning
Minssen, T., Gerke, S., Aboy, M., Price, N., & Cohen, G. (2020) · Journal of Law and the Biosciences · doi:10.1093/jlb/lsaa002 · Cited by 157 · cited 1×
“74 The pathway to FDA regulatory approval or CE marking generally begins with establishment of the product’s intended use and its class (or risk profile), 74 followed by evaluation of safety and efficacy through scientific understanding and clinical trials.”
BackgroundDawud, A. M., Yurtkan, K., & Oztoprak, H. (2019) · Computational Intelligence and Neuroscience · doi:10.1155/2019/4629859 · Cited by 143 · cited 5×
“14 In CT intracranial hemorrhage detection, Dawud et al 28 finetuned a pretrained 2D CNN model on their own dataset, achieving slightly greater accuracy (92.13”
BackgroundMethodInfluentialArtificial intelligence for decision support in acute stroke — current roles and potential
Bivard, A., Churilov, L. P., & Parsons, M. W. (2020) · Nature Reviews Neurology · doi:10.1038/s41582-020-0390-y · Cited by 127 · cited 1×
“16 17 In the context of the detection of intracranial hemorrhage, several challenges exist which affect the use of these automated systems as a clinical tool.”
MethodLabovitz, D., Halim, A., Brent, B., Boden-Albala, B. M., Hauser, W. A., & Sacco, R. L. (2006) · Neuroepidemiology · doi:10.1159/000091655 · Cited by 118
Radiology resident evaluation of head CT scan orders in the emergency department.
Erly, W. K., Berger, W. G., Krupinski, E. A., Seeger, J. F., & Guisto, J. A. (2002) · PubMed Central · Cited by 116
Alexander, A., Jiang, A., Ferreira, C., & Zurkiya, D. (2020) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2019.07.019 · Cited by 115 · cited 1×
“70 Viz. ai, which received regulatory clearance from the FDA in 2018, has demonstrated the potential for AI to reform stroke care.”
BackgroundStrub, W. M., Leach, J. L., Tomsick, T. A., & Vagal, A. S. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0653 · Cited by 112
Analysis of head CT scans flagged by deep learning software for acute intracranial hemorrhage
Ginat, D. T. (2019) · Neuroradiology · doi:10.1007/s00234-019-02330-w · Cited by 112 · cited 5×
“33 34 38 In a simulated, randomized, double-blinded clinical trial, Titano et al 33 reported that their automated DL triage tool was 150 times faster than radiologists at flagging a potential urgent CT head abnormality (1.2 s vs 177 s).”
BackgroundMethodInfluentialKazuhiro, K., Werner, R. A., Toriumi, F., Javadi, M. S., Pomper, M. G., Solnes, L. B., Verde, F., Higuchi, T., & Rowe, S. P. (2018) · Tomography · doi:10.18383/j.tom.2018.00042 · Cited by 101
Brain Hemorrhage Diagnosis by Using Deep Learning
Phong, T. D., Duong, H. N., Nguyen, H. P. N., Trong, N. T., Nguyen, V., Hoa, T. V., & Snåšel, V. (2017) · International Conference on Machine Learning and Soft Computing (ICMLSC) · doi:10.1145/3036290.3036326 · Cited by 94 · cited 1×
“29 30 Despite this, most of the winning solutions from RSNA’s intracranial hemorrhage detection Kaggle challenge incorporated TL into their algorithms, 39–41 52–56 thus highlighting it as a technique requiring further investigation.”
BackgroundDetecting Intracranial Hemorrhage with Deep Learning
Majumdar, A., Brattain, L. J., Telfer, B. A., Farris, C. W., & Scalera, J. E. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512336 · Cited by 88
The acute management of intracerebral hemorrhage
Flower, O., & Smith, M. (2010) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e328342f823 · Cited by 75
Deep Learning Application for Predicting Soil Organic Matter Content by VIS-NIR Spectroscopy
Xu, Z., Zhao, X., Xi, G., & Guo, J. (2019) · Computational Intelligence and Neuroscience · doi:10.1155/2019/3563761 · Cited by 74
Deep networks in identifying CT brain hemorrhage
Helwan, A., Fakhri, G. E., Sasanı, H., & Ozsahin, D. U. (2018) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-172261 · Cited by 65
Cranial CT interpretation by senior emergency department staff
Arendts, G., Manovel, A., & Chai, A. (2003) · Australasian Radiology · doi:10.1046/j.1440-1673.2003.01204.x · Cited by 63 · cited 1×
“Studies have shown significant discrepancies between initial interpretations of CT scans by junior radiologists or emergency physicians, and final interpretations by senior radiologists, 9–11 with missed SDHs, SAHs, 9 fractures, and chronic ischemic foci.”
BackgroundRadiology in 2018: Are You Working with AI or Being Replaced by AI?
Bluemke, D. A. (2018) · Radiology · doi:10.1148/radiol.2018184007 · Cited by 47 · cited 1×
“71 More recently approved implementations for intracranial hemorrhage detection promise similar workflow improvements.”
BackgroundModels Genesis: Generic Autodidactic Models for 3D Medical Image AnalysisPreprint
Zhou, Z., Sodha, V., Siddiquee, M. M. R., et al. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1908.06912 · Cited by 44
The acute management of intracerebral hemorrhage
Flower, O., & Smith, M. (2011) · UCL Discovery (University College London) · Cited by 44
Alberico, R. A., Loud, P. A., Pollina, J., Greco, W. R., Patel, M. R., & Klufas, R. A. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.5.1751361 · Cited by 35 · cited 1×
“67 In one implementation, the sensitivity for detecting SAH was significantly lower than for other subtypes (table 1).”
BackgroundArtificial Intelligence in Health Care: Applications and Legal IssuesPreprint
Price, & Nicholson, W. T. (2017) · SSRN Electronic Journal · Cited by 29
Karthik, R., & Menaka, R. (2017) · The Imaging Science Journal · doi:10.1080/13682199.2017.1370879 · Cited by 26 · cited 2×
“19 Additionally, to guide the learning of the ML model, specific samples with obvious pathology may be selected.”
BackgroundMethodA multiresolution binary level set method and its application to intracranial hematoma segmentation
Liao, C.-C., Xiao, F., Wong, J., & Chiang, I. (2009) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2009.04.001 · Cited by 24
Just-in-Time Radiologist Decision Support: The Importance of PACS-Integrated Workflow
Morgan, M. B., Branstetter, B. F., Clark, C., House, J., Baker, D., & Harnsberger, H. R. (2011) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2011.01.003 · Cited by 21 · cited 1×
“69 Thus, implementations should accommodate a fully automated process of CT study transference to the device performing trained network inference, and transfer back to the relevant clinical workflow tool(s).”
MethodModel Evaluation and Enhancement
Nisbet, R. A., Elder, J. F., & Miner, G. D. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374765-5.00013-9 · Cited by 21
Emergency Imaging of Intracerebral Haemorrhage
Alobeidi, F., & Aviv, R. I. (2015) · Monographs in clinical neuroscience/Frontiers of neurology and neuroscience/Monographs in neural sciences · doi:10.1159/000437110 · Cited by 17
Ortiz, A. D., Gordillo, N., Montseny, E., Aymerich, F. X., López-Cordova, M., Mejia, J. M., Ortega, L. M., & Mederos, B. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.05.037 · Cited by 13
Research works printed but not linked: 2
- Detecting Intracranial Hemorrhage with Deep Learning. 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. EMBC2018. 2018
- Machine learning in medical imaging. M L Giger, 10.1016/j.jacr.2017.12.028J Am Coll Radiol. 152018 · doi:10.1016/j.jacr.2017.12.028j
Cited by
Brain Tumor Analysis Using Deep Learning and VGG-16 Ensembling Learning Approaches
Younis, A., Qiang, L., Nyatega, C. O., Adamu, M. J., & Kawuwa, H. B. (2022) · Applied Sciences · doi:10.3390/app12147282 · Cited by 286
“Viewing the current literature, one cannot deny that Computed Tomography (CT) brain scanning is one of the most common applications of deep learning, with learning algorithms producing the most accurate results [34].”
BackgroundRandomized Controlled Trials of Artificial Intelligence in Clinical Practice: Systematic Review
Lam, T. Y. T., Cheung, M. F. K., Munro, Y. L., Lim, K. M., Shung, D., & Sung, J. J. Y. (2022) · Journal of Medical Internet Research · doi:10.2196/37188 · Cited by 120
Seyam, M., Weikert, T., Sauter, A. W., Brehm, A., Psychogios, M., & Blackham, K. A. (2022) · Radiology Artificial Intelligence · doi:10.1148/ryai.210168 · Cited by 131
“Recent publications have proven the technical feasibility of several AI tools for detecting ICH with non-contrast CT (7) and show positive impact on worklist reprioritization (8–10), report turnaround times (10,11), and hospital length of stay (11).”
BackgroundSystematic reviews of machine learning in healthcare: a literature review
Kolasa, K., Admassu, B. Y., Hołownia-Voloskova, M. E., Kędzior, K. J., Poirrier, J., & Perni, S. (2023) · Expert Review of Pharmacoeconomics & Outcomes Research · doi:10.1080/14737167.2023.2279107 · Cited by 121
Savage, C. H., Tanwar, M., Elkassem, A. M. A., Sturdivant, A. B., Hamki, O., Sotoudeh, H., Sirineni, G. K. R., Singhal, A., Milner, D. M., Jones, J. G. A., et al. (2024) · American Journal of Roentgenology · doi:10.2214/ajr.24.31639 · Cited by 93
Metadata
- Authors
- Yeo, M., Tahayori, B., Kok, H. K., Maingard, J., Kutaiba, N., Russell, J., Thijs, V., Jhamb, A., Chandra, R. V., Brooks, M., Barras, C. D., & Asadi, H.
- Affiliations
- The University of Melbourne (AU)
- Deakin University (AU)
- Austin Hospital (AU)
- Florey Institute of Neuroscience and Mental Health (AU)
- St Vincent's Hospital Melbourne (AU)
- Monash Medical Centre (AU)
- South Australian Health and Medical Research Institute (AU)
- Corresponding author
- Yeo, Melissa
- ORCID
- Venue
- Journal of NeuroInterventional Surgery
- Publisher
- BMJ
- Published
- 2021-01-21
- Volume
- 13
- Issue
- 4
- Pages
- 369-378
- ISSN
- 1759-8478 (ISSN-L)
- 1759-8486
- OpenAlex
- W3123237299
- Semantic Scholar
- 61c934a04f14859387f337d6d1d4518a8ae9dc35
- Cited by
- 65
- References
- 68
- Citations by year
- 2026: 7 · 2025: 16 · 2024: 12 · 2023: 16 · 2022: 13 · 2021: 1
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by
- Locations
- Journal of NeuroInterventional Surgery (publishedVersion)
- PubMed (publishedVersion)
- Figshare (submittedVersion, cc-by)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Intracerebral and Subarachnoid Hemorrhage Research
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Brain Tumor Detection and Classification
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- intracranial hemorrhage, deep learning, non-contrast CT, head CT, automated detection, clinical implementation of AI, neuroimaging
- MeSH terms
- Deep Learning, Algorithms, Artificial Intelligence, Head, Humans, Radiography, Tomography, X-Ray Computed, Intracranial Hemorrhages, Neuroimaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.