Analytical quantification of electrochemical ferrates for drinking water treatments
Open accessAbstract
Ferrate ions are a highly oxidizing and unstable species that are challenging to quantify and analyze. They are, however, becoming increasingly recognized as an excellent candidate for a number of applications such as for water treatment. A wider acceptance of ferrates requires an accurate assay of the produced ferrates. We report on four analytical methods (existing and new) for quantification of ferrates and discuss their advantages and disadvantages. These methods include titrimetric analysis and spectrometric techniques such as direct colorimetric measurements of ABTS or NaI colorimetric. In terms of accuracy, the cost, simplicity, and time required the modified indirect UV-Vis NaI method is shown to be the most effective of all of the four methods investigated.
Overview
AI snapshot
Written from the paper’s full text.
TL;DR
The paper evaluates four analytical methods for quantifying electrochemically generated ferrate for drinking water treatment and modifies them for high-pH, low-concentration solutions. It concludes that the modified indirect UV-Vis/NaI method is the most effective overall in accuracy, cost, simplicity, and time.
Key findings
- The modified indirect UV-Vis/NaI method was the most effective of the four methods investigated, being stable, easy to prepare, low cost, suitable for low µM ferrate concentrations, and producing less hazardous waste.
- Against the titration benchmark of 17.3 ± 0.1 mM ferrate, direct UV-Vis gave 16.9 ± 0.4 mM, ABTS gave 17.32 ± 0.03 mM, and NaI gave 17.27 ± 0.08 mM.
- Direct UV-Vis at 505 nm is limited by low molar absorptivity and cannot quantify samples below 70 µM Fe(VI); ABTS at 415 nm reaches absorbance ~1 with only 35 µM ferrate, while NaI at 351 nm requires 27 µM, compared with 700 µM for direct UV-Vis.
- Centrifuging improved quantification in the presence of Fe(III): titration gave 1.25 mM centrifuged vs 1.11 mM non-centrifuged; direct UV-Vis gave 1.22 mM vs 1.08 mM; for NaI at 5 µL, absorbance was 0.170 (4.2 µM) vs 0.120 (3.1 µM); for ABTS, 0.140 (3.5 µM) vs 0.120 (2.9 µM).
Methods
- Electrochemical ferrates were generated in a two-compartment glass cell separated by a Nafion NR-112 cation exchange membrane, using a carbon steel anode and stainless steel cathode in 14 M NaOH, galvanostatically at 10 mA cm⁻² for 24 hours.
- Four quantification methods were tested: modified Schreyer titrimetric analysis, direct ferrate UV-Vis at 505 nm, indirect ABTS UV-Vis at 415 nm, and modified indirect NaI UV-Vis at 351 nm using a pH 9 phosphate buffer.
- Absorbance measurements used a Cary 100 spectrophotometer with 1 cm quartz cells; methods were compared for preparation time, test time, waste, toxicity, stability, accuracy, precision, range, and consumables cost.
Limitations
- Stated in the paper: titration is time-consuming (~40 min), requires at least 5 mL of ferrate solution, uses hazardous acids and toxic Cr(VI), and costs about $30 USD per trial; direct UV-Vis has low molar absorptivity, cannot measure below 70 µM, and is subject to colloidal Fe(III) interference; ABTS solution is unstable and must be used fresh within about 30 minutes, generates organic waste, and costs about $3 USD per trial; conventional NaI is only applicable at pH 5.5–9.3, requiring the paper’s pH 9 buffer modification.
- Evident from the text: the comparison relies on consumables cost and qualitative ratings, with uncertainty reported mainly as standard deviations from 3 or more measurements; the electrochemical ferrate matrix differs from the solid-ferrate solutions for which the original methods were developed.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 of 31 cited sources checked · 0 supported · 1 flagged · accuracy not yet measured
- Findingcitation
The ABTS absorption maxima occur at about 415 nm.
“The maxima of the spectra for ABTS occur at about 415 nm in agreement with the results reported by Lee et.al 20 .”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [20]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Findingnone given
The direct colorimetric method provides more accurate measurements for concentrations higher than 100 μM.
“The direct colorimetric method provides more accurate measurements for concentrations higher than 100 µM.”
Quote in the paperNot a substantial claim - Findingnone given
The titration method requires at least 5 mL of ferrate solution for a single measurement.
“In addition, this method requires at least 5 mL of ferrate solution for a single measurement, thus making it difficult to do multiple quantifications with small samples”
Quote in the paperSubstantial claim - Findingown data
The molar absorptivity at 351 nm is 0.0396 μM cm -1 (R 2 =0.9972).
“The molar absorptivity at 351 nm is 0.0396 µM cm -1 (R 2 =0.9972).”
Quote in the paperSubstantial claim - Findingnone given
For testing at pH higher than 9, no I 3 - peak was observed.
“However, for testing at pH higher than 9 no I 3 -peak was observed.”
Quote in the paperSubstantial claim
- Findingnone given
After about 30 minutes at room temperature, the ABTS solution begins to decompose changing its blank absorption values.
“After about 30 minutes, at room temperature, the ABTS solution begins to decompose changing its blank absorption values.”
Quote in the paperSubstantial claim - Findingown data
The absorption spectra for the NaI method show a maximum absorption peak at about 351 nm.
“Figure 6 shows the absorption spectra for a number of different ferrate concentrations with the maximum absorption peak at about 351 nm, in agreement with previous studies 13 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [13] source
- Findingown data
Titrations take on average about 40 minutes to complete.
“We find that these titrations take on average about 40 minutes to complete.”
Quote in the paperSubstantial claim - Findingreasoning
The ABTS method leads to highly accurate measurements for low ferrate concentrations as compared with the titration method.
“The ABTS method leads to highly accurate measurements for low ferrate concentrations as compared with D r a f t 14 the titration method.”
Quote in the paperSubstantial claim - Findingown data
For a 17.3 ± 0.1 mM ferrate concentration using the titration method, the ABTS method gave 17.32 ± 0.03 mM.
“For example, for a 17.3 ± 0.1 mM ferrate concentration (using the titration method) the value for ABTS method was 17.32 ± 0.03 mM.”
Quote in the paperSubstantial claim - Findingnone given
The NaI holding solution can be left for extended periods of time without degrading or reacting.
“Compared to the ABTS indirect method, the NaI holding solution can be left for extended periods of time without degrading or reacting which makes it feasible method for use in multiple samples requiring more time.”
Quote in the paperNot a substantial claim - Findingown data
For a 17.3 ± 0.1 mM ferrate concentration using the titration method, the direct UV-Vis measurement was 16.9 ± 0.4 mM.
“For example for a 17.3 ± 0.1 mM concentration using the titration method, the value for direct UV-Vis measurement was 16.9 ± 0.4 mM, which is in reasonable agreement.”
Quote in the paperSubstantial claim - Findingcitation
The molar absorptivity of Fe (VI) at 505 nm is low (1.5 x 10 3 M -1 cm -1 , R 2 = 0.99976).
“because the molar absorptive of Fe (VI) at 505 nm is low (1.5 x 10 3 M -1 cm -1 , R 2 = 0.99976) 13 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [13] source
- Findingown data
The molar absorptivity of ABTS is 3.7 x 10 4 M -1 cm -1 ( R 2 =0.99858).
“The molar absorptivity is 3.7 x 10 4 M -1 cm -1 ( R 2 =0.99858) for ABTS.”
Quote in the paperSubstantial claim - Findingown data
The increase in the absorbance peak at 351 nm is linear with respect to the concentration of Fe (VI).
“The increase in the absorbance peak at 351 nm is linear with respect to the concentration of Fe (VI).”
Quote in the paperSubstantial claim - Findingnone given
The titration method involves hazardous chemicals like acids and toxic Cr (VI) ions.
“and it involves hazardous chemicals like acids and toxic Cr (VI) ions.”
Quote in the paperSubstantial claim - Findingown data
For a 17.3 ± 0.1 mM ferrate concentration using titration, the NaI method gave 17.27 ± 0.08 mM.
“For example, for a 17.3 ± 0.1 mM ferrate concentration (using titration), the value for the NaI method was 17.27 ± 0.08 mM.”
Quote in the paperSubstantial claim - Interpretationown data
The modified indirect UV-Vis/NaI method is the most effective of all four methods investigated in terms of accuracy, cost, simplicity and time required.
“In terms of accuracy, cost, simplicity and time required the modified indirect UV-Vis/NaI method is shown to be the most effective of all the four methods investigated.”
Quote in the paperSubstantial claim - Premisecitation
The redox potential of ferrate (VI) ions is greater than other commonly used oxidizing agents in water treatment such as chlorine (1.358 V vs. SHE) and ozone (2.076 V vs. SHE).
“The redox potential of ferrate (VI) ions is greater than other commonly used oxidizing agents in water treatment such as chlorine (1.358 V vs. SHE) and ozone (2.076 V vs. SHE) 5 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [5] source
- Premisecitation
The NaI method uses sodium iodide solution to determine concentrations of Fe (VI) at low (< 10 μM) concentrations levels in water.
“The method uses sodium iodide (NaI) solution to determine concentrations of Fe (VI) at low (< 10 µM) concentrations levels in water 12,13 .”
Quote in the paperSubstantial claim0 of 2 sources checked - Interpretationreasoning
Centrifuging the sample prior to the adsorption measurement can avoid interference from colloidal Fe (III) oxides.
“This problem can D r a f t 13 be avoided by centrifuging the sample prior to the adsorption measurement.”
Quote in the paperSubstantial claim - Premisecitation
Common quantification methods for electrochemically-generated ferrates face challenges such as high pH conditions, low concentration of ferrates (μM range), and the presence of Fe 3+ .
“Although, electrochemical synthesis of Fe 6+ is very promising for water treatment applications, the common quantification methods for the electrochemically-generated ferrates face a number of challenges such as high pH conditions, low concentration of ferrates (µM range), and the presence of Fe 3+ .”
Quote in the paperSubstantial claim0 of 3 sources checked - Interpretationown data
In the presence of Fe (III), the additional step of sample centrifuging was shown to be an important step for improving measurement accuracy.
“In the presence of Fe (III), the additional step of sample centrifuging was shown to be an important step for improving measurement accuracy.”
Quote in the paperSubstantial claim - Interpretationreasoning
The key for successful measurement of electrochemically generated ferrate appears to be the modification of these techniques to keep the pH at the optimum value for each quantification method.
“The key for successful measurement of electrochemically generated ferrate appears to be the modification of these techniques to keep the pH at the optimum value for each quantification method.”
Quote in the paperSubstantial claim - Premisecitation
Ferrates have been shown to be very effective in the removal of Escherichia Coli, fecal coliform, sulphur and nitrogen containing contaminants and toxins.
“In particular, they have been shown to be very effective in the removal of Escherichia Coli, fecal coliform, sulphur and nitrogen containing contaminants 1 and toxins 2 .”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [1] Sharma V. K., 2005, J. Water Health source
- cites [2]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Interpretationreasoning
The difference between centrifuged and non-centrifuged titration data could partially be explained by non-soluble Fe (III) compounds suspended in the non-centrifuged sample occupying volume that would otherwise be ferrate solution.
“The difference between centrifuged and non-centrifuged data could partially be explained by the fact that the non-soluble Fe (III) compounds, which are suspended in the non-centrifuged sample and which D r a f t 17 do not react during titration, will be pipetted, thus occupying volume that would otherwise be ferrate solution.”
Quote in the paperNot a substantial claim - Premisecitation
The NaI method is generally applicable for a pH range of 5.5 to 9.3.
“This method is generally applicable for a pH range of 5.5 to 9.3 12 .”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [12] source
- Premisecitation
Ferrate anions are very suitable for use in drinking water treatment.
“Ferrate anions are very suitable for use in drinking water treatment.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [1] Sharma V. K., 2005, J. Water Health source
- cites [2]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- It may state two separate claims as one. 26
- Probably not a substantial claim. 9
It may state two separate claims as one.
PremisecitationThe titrimetric method proposed by Schreyer is considered the most accurate method for quantification of ferrates and has been used as a standard procedure to benchmark other methods.
“The titrimetric method proposed by Schreyer et al.(J.M. Schreyer, G. W. Thompson', 1950) is considered the most accurate method for quantification of ferrates”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [14] source
The Introduction says the paper’s amperometric method has better precision and accuracy than the volumetric chromite method, and the Results and discussion report better reproducibility for the amperometric method. The Titration procedure confirms that the chromite method was used for comparison, but the paper does not call it the most accurate method; it says the opposite for the methods compared. Page numbers are unavailable in our copy. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
It may state two separate claims as one.
FindingreasoningThe direct ferrate UV-Vis technique provides adequate accuracy and moderate precision, but due to its low molar absorptivity it is not possible to quantify samples with concentrations smaller than 70 μM of Fe (VI).
“The direct ferrate UV-Vis technique provides adequate accuracy and moderate precision. Due to its low molar absorptivity, it is not possible to quantify samples with concentrations smaller than 70 µM of Fe (VI) by the direct UV-Vis colorimetric method.”
Quote in the paperSubstantial claimIt may state two separate claims as one.
FindingreasoningThe NaI method requires a 27 μM solution of ferrate for an absorbance around 1, compared to the 700 μM concentration required by direct UV-Vis ferrate spectrophotometry.
“The NaI method requires a 27 µM solution of ferrate for an absorbance around 1, compared to the 700 µM concentration required by direct UV-Vis ferrate spectrophotometry.”
Quote in the paperSubstantial claimIt may state two separate claims as one.
Findingown dataIn the NaI method for 5 μL, the centrifuged ferrate solution resulted in an absorbance of 0.170, compared to the non-centrifuged value of 0.120, corresponding to 4.2 μM and 3.1 μM respectively.
“In the case of NaI (Figure 8a) for 5µL, the centrifuged ferrate solution resulted in an absorbance of 0.170, compared to the non-centrifuged value of 0.120, corresponding to 4.2 µM and 3.1 µM respectively.”
Quote in the paperNot a substantial claimProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds. It may state two separate claims as one.
Findingnone givenThe costs associated with the NaI technique compared to the ABTS method are significantly lower; NaI costs about $1 USD per gram whereas ABTS costs about $60 USD per gram.
“Furthermore, the costs associated with this technique, compared to the ABTS method, are significantly lower.The cost of NaI is about $1 USD per gram whereas that of ABTS is about $60 USD per gram.”
Quote in the paperNot a substantial claimIt may state two separate claims as one.
Findingown dataFor the direct colorimetric method, the concentration of the centrifuged ferrate solution was 1.22 mM while the non-centrifuged solution had a concentration of 1.08 mM.
“For the direct colorimetric method the concentration of the centrifuged ferrate solution was 1.22 mM while the non-centrifuged solution had a concentration of 1.08 mM.”
Quote in the paperNot a substantial claimIt may state two separate claims as one.
Findingown dataThe ferrate spectra show a maximum at 505 nm and two minima at 390 nm and 670 nm.
“The ferrate spectra show a maximum at 505 nm and two minima at 390 nm and 670 nm in close agreement with previous studies 13 .”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [13] source
Probably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
Findingnone givenThe cost of consumables for the titration method is estimated to be about $30 USD per trial.
“The cost of consumables involved for this method is estimated to be about $30 USD per trial.”
Quote in the paperNot a substantial claimIt may state two separate claims as one.
Findingown dataIn the ABTS method, the centrifuged ferrate solution gave an absorbance of 0.140 (3.5 μM) and the non-centrifuged gave 0.120 (2.9 μM).
“A similar effect was obtained with the ABTS method, i.e., an absorbance of 0.140 (3.5 µM) and 0.120 (2.9 µM) for the centrifuged and non-centrifuged ferrate solutions, respectively.”
Quote in the paperNot a substantial claimIt may state two separate claims as one.
FindingreasoningA ferrate solution of 700 μM has an absorption value of around 1, whereas ABTS + reaches the same value of absorption with a ferrate concentration of only 35 μM.
“A ferrate solution of 700 µM has an absorption value of around 1, whereas ABTS + reaches the same value of absorption with a much smaller ferrate concentration of only 35 µM.”
Quote in the paperSubstantial claimProbably not a substantial claim. It may state two separate claims as one.
Findingnone givenAnalyzing multiple samples with the ABTS method is time consuming and generates a lot of organic chemical waste coming from ABTS.
“Furthermore, analyzing multiple samples is time consuming and generates a lot of organic chemical waste coming from ABTS.”
Quote in the paperSubstantial claimProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
Findingnone givenThe cost of consumables for the ABTS method is estimated to be about $3 USD per trial.
“The cost of consumables involved for this method is estimated to be about $3 USD per trial.”
Quote in the paperNot a substantial claimIt may state two separate claims as one.
Findingown dataThe ABTS + radical has a higher molar absorptivity than ferrate, allowing for better sensitivity and more accurate results with low ferrate concentrations.
“The ABTS + radical has a higher molar absorptivity than ferrate, allowing for better sensitivity and more accurate results with low ferrate concentrations”
Quote in the paperSubstantial claimIt may state two separate claims as one.
FindingreasoningThe indirect NaI UV-Vis method is stable, easy to make, environmentally benign, does not lead to harmful wastes, and is ideal for water treatment applications.
“The indirect NaI UV-Vis method is a very good option because it is stable, easy to make, environmentally benign, and does not lead to harmful wastes.For UV-Vis measurements, smaller concentrations of ferrate are required resulting in smaller concentrations of ferrate that can be detected, thus making it ideal for water treatment applications.”
Quote in the paperSubstantial claimProbably not a substantial claim. The paper’s conclusions may not depend on it.
Findingnone givenThe cost of consumables for the direct UV-Vis method is estimated to be about $0.1 USD per test.
“The cost of consumables involved for this method is low and estimated to be about $0.1 USD per test.”
Quote in the paperNot a substantial claimProbably not a substantial claim. The paper’s conclusions may not depend on it. It may state two separate claims as one.
Findingnone givenThe NaI method can be carried out using just 4 mL of a 0.1 M NaI buffer pH 9 solution, decreasing the quantity of generated waste.
“The NaI method can also be carried out using just 4 mL of a 0.1 M NaI buffer pH 9 solution, decreasing the quantity of generated waste.”
Quote in the paperNot a substantial claimProbably not a substantial claim. The paper’s conclusions may not depend on it. The paper may give no reason why it holds.
Findingnone givenThe cost of consumables for the NaI method is estimated to be about $0.1 USD per trial.
“The cost of consumables involved for this method is estimated to be about $0.1 USD per trial.”
Quote in the paperNot a substantial claimIt may state two separate claims as one.
Findingown dataThe ferrate concentrations of the centrifuged and non-centrifuged samples, using the chemical titration method, were 1.25 mM and 1.11 mM, respectively.
“The ferrate concentrations of the centrifuged and non-centrifuged samples, using the chemical titration method, were 1.25 mM and 1.11 mM, respectively.”
Quote in the paperSubstantial claimProbably not a substantial claim. The paper may give no reason why it holds.
Findingnone givenThe waste generated from the NaI method is significantly less hazardous than that of other quantification methods.
“The waste generated from this method is also significantly less hazardous than that of other quantification methods.”
Quote in the paperNot a substantial claimIt may state two separate claims as one.
Findingnone givenThe indirect ABTS-based spectrophotometric method is very simple, efficient, and highly accurate, but the ABTS solution is not stable and degradation will lead to erroneous results.
“The indirect ABTS-based spectrophotometric method is a very simple, efficient, and a highly accurate method.However, the ABTS solution is not stable and degradation of the ABTS solution will lead to erroneous results.”
Quote in the paperSubstantial claimIt may state two separate claims as one.
PremisecitationABTS solutions are unstable and must be used within 30 minutes after preparation.
“however ABTS solution are unstable and must be used within 30 minutes after preparation 12,13,18 .”
Quote in the paperNot a substantial claim0 of 3 sources checkedIt may state two separate claims as one.
PremisecitationOzonation is ineffective in alkaline conditions and may result in the formation of carcinogenic bromates when bromides ions are present in water.
“Ozonation is an alternative disinfection method, but it is ineffective in alkaline conditions and may result in the formation of carcinogenic bromates when bromides ions are present in water 1 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [1] Sharma V. K., 2005, J. Water Health source
It may state two separate claims as one.
PremisecitationThe wet chemical method for ferrate production has a relatively low yield (10-15%) and requires additional reagents and further steps to purify and separate the desired product, leading to high costs.
“This process has a is relatively low yield (10-15%) and additional reagents and further steps are required to further purify and separate the desired product, leading to high costs 1 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [1] Sharma V. K., 2005, J. Water Health source
Probably not a substantial claim. It may state two separate claims as one.
Premisenone givenElectrochemical generation of ferrates requires neither hazardous reagents nor high temperatures.
“Electrochemical generation of ferrates is an attractive alternative method of preparation, because it requires neither hazardous reagents nor high temperatures.”
Quote in the paperSubstantial claimIt may state two separate claims as one.
PremisecitationDry thermal synthesis of ferrate (VI) is expensive because of high energy consumption and dangerous due to potential detonation at high temperatures.
“On the other hand, dry thermal synthesis of ferrate (VI) is performed at elevated temperatures (370 °C), and is considered to be expensive because of high energy consumption, and it is dangerous due to potential detonation at high temperatures 8 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] source
It may state two separate claims as one.
PremisecitationThe ferrate solution tends to decompose to yield colloidal Fe (III) oxides, which can interfere with the spectral measurements.
“In addition, the ferrate solution tends to decompose to yield colloidal Fe (III) oxides, which can interfere with the spectral measurements 19 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
It may state two separate claims as one.
PremisecitationTraditional chlorination treatment processes have challenges including high dosages and long contact time, which lead to the formation of carcinogenic disinfection byproducts (DBPs) such as trichloromethanes.
“Challenges with the use of traditional chlorination treatment processes include high dosages and long contact time, which lead to the formation of carcinogenic disinfection byproducts (DBPs) such as trichloromethanes 1 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [1] Sharma V. K., 2005, J. Water Health source
It may state two separate claims as one.
Interpretationown dataCentrifuging the ferrate solution in the presence of Fe (III) helps in physical separation of insoluble species from the solution and leads to higher absorbance values.
“Centrifuging the ferrate solution in the presence of Fe (III) helps in physical separation of insoluble species from the solution and leads to higher absorbance values.”
Quote in the paperSubstantial claimIt may state two separate claims as one.
PremisecitationPhosphates stabilize Fe (III) by surface complexation, avoiding the formation of hydroxides that can interfere in the UV-VIS reading.
“Phosphates stabilize Fe (III) by surface complexation 21 , avoiding the formation of hydroxides that interfer in the UV-VIS reading 18 .”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [21]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- cites [18] source
It may state two separate claims as one.
InterpretationreasoningThe NaI and ABTS methods measure the absorbance of the I 3 - and ABTS + ions generated as a result of chemical reactions with ferrate, allowing them to account only for the presence of ferrate while any Fe (III) ions are left unreacted.
“The NaI and ABTS methods measure the absorbance of the I 3 -and ABTS + ions, respectively, which are generated as a result of chemical reactions with ferrate.This allows for the ability to account only for the presence of ferrate while any Fe (III) ions are left unreacted.”
Quote in the paperSubstantial claimIt may state two separate claims as one.
PremisecitationFerrates have a high standard half-cell reduction potential (2.20 V vs. SHE), non-toxic reduction byproducts (Fe 3+ ), and the simultaneous capacity to act as both an oxidant and coagulant agent.
“The suitability of ferrates is a consequence of their unique properties such as: a) a high standard half-cell reduction potential (2.20 V vs. SHE), b) non-toxic reduction byproducts (Fe 3+ ), and c) the simultaneous capacity to act as both an oxidant and coagulant agent 3 .”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [3] source
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
ABTS cost per trial conflicts with Table 1
MajorThe text estimates ABTS consumables at $3 per trial, but Table 1 lists $0.5 per sample under Indirect ABTS.
“The cost of consumables involved for this method is estimated to be about $3 USD per trial.”
“| Cost per sample | $30 USD | $0.1 USD | $3 USD | $0.5 USD |”
NaI cost per trial conflicts with Table 1
MajorThe text estimates NaI consumables at $0.1 per trial, but Table 1 lists $3 per sample under Indirect NaI.
“The cost of consumables involved for this method is estimated to be about $0.1 USD per trial.”
“| Cost per sample | $30 USD | $0.1 USD | $3 USD | $0.5 USD |”
NaI centrifuging difference exceeds the stated limit
MinorThe stated NaI concentrations differ by 1.1 μM (4.2 minus 3.1), contradicting the claim that the difference was lower than 1 μM in both methods.
“corresponding to 4.2 µM and 3.1 µM respectively.”
“however in both cases the different between centrifuged and noncentrifuged was lower than 1 µM.”
Two blank-absorbance values are assigned the same path length
MinorThe ABTS replacement criterion gives both 0.02 and approximately 0.2 as the blank absorbance in a 10 cm path length.
“0.02 at 415 nm and in a 10 cm path length”
“(about 0.2 in 10 cm path length)”
Two different NaI buffer recipes are given
MinorThe experimental section specifies 995 mL of phosphate solution plus 45 mL of HCl, whereas the results section specifies 955 mL plus 45 mL for the modified NaI buffer.
“a pH 9 buffer was prepared by combining of 995 mL of 0.1 M Na 2 HPO 4 and 45 mL of 0.1 M HCl.”
“a buffer solution prepared with 955 mL of 0.1 M disodium hydrogen phosphate and 45 mL 0.1 M HCl.”
Citations
Cites
Jiang, J.-Q., & Lloyd, B. (2002) · Water Research · doi:10.1016/s0043-1354(01)00358-x · Cited by 443
Spectrophotometric determination of ferrate (Fe(VI)) in water by ABTS
Lee, Y., Yoon, J., & von Gunten, U. (2005) · Water Research · doi:10.1016/j.watres.2005.03.005 · Cited by 256
Rush, J. D., & Bielski, B. H. J. (1986) · Journal of the American Chemical Society · doi:10.1021/ja00263a037 · Cited by 151
Jiang, Y., Goodwill, J. E., Tobiason, J. E., & Reckhow, D. A. (2015) · Environmental Science & Technology · doi:10.1021/es505516w · Cited by 147
Advances in the development and application of ferrate(VI) for water and wastewater treatment
Jiang, J. (2014) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4214 · Cited by 146
Research progress in the electrochemical synthesis of ferrate(VI)
Mácová, Z., Bouzek, K., Híveš, J., Sharma, V. K., Terryn, R. J., & Baum, J. C. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2008.11.034 · Cited by 141
Methodologies for the analytical determination of ferrate(VI): A Review
Luo, Z., Strouse, M., Jiang, J., & Sharma, V. K. (2011) · Journal of Environmental Science and Health Part A · doi:10.1080/10934529.2011.551723 · Cited by 132
Ferrates (iron(VI) and iron(V)): Environmentally friendly oxidants and disinfectants
Sharma, V. K., Kazama, F., Jiangyong, H., & Ray, A. K. (2005) · Journal of Water and Health · doi:10.2166/wh.2005.0005 · Cited by 131
Licht, S., Naschitz, V., Halperin, L., Halperin, N., Lin, L., Chen, J., Ghosh, S., & Liu, B. (2001) · Journal of Power Sources · doi:10.1016/s0378-7753(01)00786-8 · Cited by 122
Alsheyab, M. A. T., Jiang, J., & Stanford, C. (2008) · Journal of Environmental Management · doi:10.1016/j.jenvman.2008.10.001 · Cited by 115
Oxidation of Chromium(III) with Potassium Ferrate(VI)
Schreyer, J. M., Thompson, G. W., & Ockerman, L. T. (1950) · Analytical Chemistry · doi:10.1021/ac60047a022 · Cited by 77
Bouzek, K., Schmidt, M. J., & Wragg, A. A. (1999) · Electrochemistry Communications · doi:10.1016/s1388-2481(99)00075-2 · Cited by 53
Electrochemical synthesis of ferrate using boron doped diamond anodes
Cañizares, P., Arcís, M., Sáez, C., & Rodrigo, M. A. (2007) · Electrochemistry Communications · doi:10.1016/j.elecom.2007.06.034 · Cited by 48
Zhang, C., Liu, Z., Wu, F., Lin, L., & Qi, F. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2004.08.011 · Cited by 31
Golovko, D., Sharma, V. K., Suprunovich, V. I., Павлова, О. В., Головко, И. Д., Bouzek, K., & Zbořil, R. (2011) · Analytical Letters · doi:10.1080/00032719.2010.511748 · Cited by 24
Golovko, D., Sharma, V., Pavlova, O., Belyanovskaya, E., Golovko, I., Suprunovich, V., & Zboril, R. (2011) · Open Chemistry · doi:10.2478/s11532-011-0069-8 · Cited by 4
Electrochemical Fe(VI) Water Purification and Remediation
Licht, S. L., Yu, X., & Qu, D. (2008) · ACS symposium series · doi:10.1021/bk-2008-0985.ch016 · Cited by 4
Flagged first, then by citations
Cited by
Sorted by citations
McBeath, S. T., Zhang, Y., & Hoffmann, M. R. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.2c09237 · Cited by 34
McBeath, S. T., Wilkinson, D. P., & Graham, N. J. D. (2020) · Chemosphere · doi:10.1016/j.chemosphere.2020.126626 · Cited by 33
Self-citationMcBeath, S. T., Wilkinson, D. P., & Graham, N. J. D. (2020) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2020.103834 · Cited by 32
Self-citationMcBeath, S. T., Wilkinson, D. P., & Graham, N. J. D. (2020) · Environmental Science Water Research & Technology · doi:10.1039/d0ew00261e · Cited by 26
Self-citationDeka, B. J., Guo, J., Jeong, S., Kumar, M., & An, A. K. (2020) · Environmental Science Water Research & Technology · doi:10.1039/c9ew00955h · Cited by 24
Elnakar, H., & Buchanan, I. (2018) · Journal of Environmental Management · doi:10.1016/j.jenvman.2018.10.076 · Cited by 23
Electrosynthesis of ferrate in a batch reactor at neutral conditions for drinking water applications
Hernández, M. C., Govindarajan, R., Bonakdarpour, A., Mohseni, M., & Wilkinson, D. P. (2018) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.23142 · Cited by 22
Self-citationDeka, B. J., Jeong, S., Tabatabai, S. A. A., & An, A. K. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.05.052 · Cited by 19
Elnakar, H., & Buchanan, I. (2020) · Journal of Environmental Engineering · doi:10.1061/(asce)ee.1943-7870.0001754 · Cited by 18
Hernández, M. C., Stewart, M., Bonakdarpour, A., Mohseni, M., & Wilkinson, D. P. (2017) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.23073 · Cited by 16
Self-citationHernández, M. C., Bonakdarpour, A., English, J. T., Mohseni, M., & Wilkinson, D. P. (2019) · Reaction Chemistry & Engineering · doi:10.1039/c8re00306h · Cited by 15
Self-citationAdvanced Techniques for Wastewater Treatment: A Review
Yadav, S. (2019) · Open Access Journal of Waste Management & Xenobiotics · doi:10.23880/oajwx-16000126 · Cited by 2
Development of a CFD-based model for simulation of UV-LED reactors for water treatment
Keshavarzfathy, M. (2020) · cIRcle (University of British Columbia) · doi:10.14288/1.0376533 · Cited by 1
Tiwari, D., Jung, J., Ralte, L., Tiwari, D., & Payanthoth, N. S. (2026) · CRC Press eBooks · doi:10.1201/9781003786221
Metadata
- Authors
- Cataldo Hernández, M. A., May, A., Bonakdapour, A., Mohseni, M., & Wilkinson, D. P.
- Affiliations
- Department of Chemical and Biological Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
- University of British Columbia (CA)
- Venue
- Canadian Journal of Chemistry
- Publisher
- Canadian Science Publishing
- Published
- 2017-01
- Volume
- 95
- Issue
- 1
- Pages
- 105-112
- ISSN
- 0008-4042 (ISSN-L)
- 1480-3291
- OpenAlex
- W2546201748
- Cited by
- 14
- References
- 17
- Citations by year
- 2026: 1 · 2023: 1 · 2020: 6 · 2019: 2 · 2018: 3 · 2017: 1
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Update notices
- correction (2017-09-23)
- Open access
- green
- hdl.handle.net
- Locations
- Canadian Journal of Chemistry (publishedVersion)
- TSpace (University of Toronto) (acceptedVersion)
- Funders
- Universities Space Research Association
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Environmental Science › Water Science and Technology › Advanced oxidation water treatment
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
- Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
- Keywords
- drinking water treatment, titration, colorimetric assay, ABTS, sodium iodide, UV-Vis spectroscopy, analytical method comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review