The DOI matches its Crossref record.
THE REASON FOR THE SHAPE OF THE DISTENSIBILITY CURVES OF ARTERIES
Abstract
It is characteristic of arteries that they do not obey Hooke's law, but resist further stretch more strongly, the more they are stretched. It appears that this might be due to the combination of elastin fibers in the elastic laminae, with the much less distensible collagenous libers in the media and adventitia, more and more of which reach their 'unstretched length' as distension is increased. This has been verified on human iliac arteries, from autopsy, by comparing the 'elastic diagrams' (tension vs. circumference) before and after differential digestion of collagen by formic acid, and digestion of elastin by crude trypsin (containing an elastase). This proved that the resistance to stretch at low pressures was almost entirely due to elastin fibers, that at physiological pressures due to both collagenous and elastin fibers, but dominantly to collagen, and that at high pressures almost entirely due to collagenous fibers. In future work on the effect of age on the elasticity of iliac arteries, the initial slope of the elastic diagram can be taken as an index of the state, or number, of the elastin fibers, and the final slope as an index of the state, or number, of collagenous fibers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hyperelastic modelling of arterial layers with distributed collagen fibre orientations
Gasser, T. C., Ogden, R. W., & Holzapfel, G. A. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0073 · Cited by 2,411
Vascular Extracellular Matrix and Arterial Mechanics
Wagenseil, J. E., & Mecham, R. P. (2009) · Physiological Reviews · doi:10.1152/physrev.00041.2008 · Cited by 1,059
Holzapfel, G. A., Sommer, G., Gasser, C. T., & Regitnig, P. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00934.2004 · Cited by 985
Noninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823
A Lamellar Unit of Aortic Medial Structure and Function in Mammals
WOLINSKY, H., & GLAGOV, S. (1967) · Circulation Research · doi:10.1161/01.res.20.1.99 · Cited by 742
The static elastic properties of the arterial wall
Bergel, D. H. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006686 · Cited by 661
A new Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models
Holzapfel, G. A., Gasser, T. C., & Ogden, R. W. (2006) · Cardiovascular Soft Tissue Mechanics · doi:10.1007/0-306-48389-0_1 · Cited by 648
Ageing of the conduit arteries
Greenwald, S. (2007) · The Journal of Pathology · doi:10.1002/path.2101 · Cited by 637
Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension.
O'Rourke, M. (1990) · Hypertension · doi:10.1161/01.hyp.15.4.339 · Cited by 622
Structural Basis for the Static Mechanical Properties of the Aortic Media
WOLINSKY, H., & GLAGOV, S. (1964) · Circulation Research · doi:10.1161/01.res.14.5.400 · Cited by 598
Holzapfel, G. A., Gasser, T. C., & Stadler, M. (2002) · European Journal of Mechanics - A/Solids · doi:10.1016/s0997-7538(01)01206-2 · Cited by 479
Age-related vascular stiffening: causes and consequences
Kohn, J. C., Lampi, M. C., & Reinhart-King, C. A. (2015) · Frontiers in Genetics · doi:10.3389/fgene.2015.00112 · Cited by 440
“At low degrees of stretch, the compliant elastin fibers dominate the mechanics, while at higher levels of deformation, helically oriented collagen fibers are recruited (Roach and Burton, 1957; Schriefl et al., 2012).”
BackgroundPhysical factors in the initiation, growth, and rupture of human intracranial saccular aneurysms
Ferguson, G. G. (1972) · Journal of Neurosurgery · doi:10.3171/jns.1972.37.6.0666 · Cited by 442
Decellularized Native and Engineered Arterial Scaffolds for Transplantation
Dahl, S. L. M., Koh, J., Prabhakar, V., & Niklason, L. E. (2003) · Cell Transplantation · doi:10.3727/000000003108747136 · Cited by 406
Role of arterial stiffness in cardiovascular disease
Cecelja, M., & Chowienczyk, P. (2012) · JRSM Cardiovascular Disease · doi:10.1258/cvd.2012.012016 · Cited by 400
Shadwick, R. E. (1999) · Journal of Experimental Biology · doi:10.1242/jeb.202.23.3305 · Cited by 398
Dobrin, P. B. (1984) · Archives of Surgery · doi:10.1001/archsurg.1984.01390160041009 · Cited by 383
Biomechanics of the gastrointestinal tract
GREGERSEN, H., & KASSAB, G. (1996) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.1996.tb00267.x · Cited by 362
Schriefl, A. J., Zeindlinger, G., Pierce, D. M., Regitnig, P., & Holzapfel, G. A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0727 · Cited by 353
Generation of Synthetic Elastin-Mimetic Small Diameter Fibers and Fiber Networks
Huang, L., McMillan, R. A., Apkarian, R. P., Pourdeyhimi, B., Conticello, V. P., & Chaikof, E. L. (2000) · Macromolecules · doi:10.1021/ma991858f · Cited by 352
Elastin, arterial mechanics, and cardiovascular disease
Cocciolone, A. J., Hawes, J. Z., Staiculescu, M. C., Johnson, E. O., Murshed, M., & Wagenseil, J. E. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00087.2018 · Cited by 341
A polyconvex framework for soft biological tissues. Adjustment to experimental data
Balzani, D., Neff, P., Schröder, J., & Holzapfel, G. A. (2006) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2005.07.048 · Cited by 333
Concussion in Professional Football: Brain Responses by Finite Element Analysis: Part 9
Viano, D. C., Casson, I. R., Pellman, E. J., Zhang, L., King, A. I., & Yang, K. H. (2005) · Neurosurgery · doi:10.1227/01.neu.0000186950.54075.3b · Cited by 292
Abdominal Aortic Aneurysms: Basic Mechanisms and Clinical Implications
Thompson, R. W., Geraghty, P. J., & Lee, J. K. (2002) · Current Problems in Surgery · doi:10.1067/msg.2002.121421 · Cited by 283
Holzapfel, G. A., Gasser, T. C., & Ogden, R. W. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1695572 · Cited by 282
The role of elastin in aortic valve mechanics
Vesely, I. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00122-x · Cited by 265
Compliance and diameter in the human abdominal aorta—The influence of age and sex
Sonesson, B., Hansen, F., Stale, H., & Länne, T. (1993) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80718-2 · Cited by 252
Ehlers–Danlos Syndrome and Postural Tachycardia Syndrome: A relationship study
Wallman, D., Weinberg, J., & Hohler, A. D. (2014) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2014.03.002 · Cited by 100
Structural basis for the changing physical properties of human pulmonary vessels with age.
Mackay, E. H., Banks, J., Sykes, B., & Lee, G. (1978) · Thorax · doi:10.1136/thx.33.3.335 · Cited by 102
Elastin-like protein matrix reinforced with collagen microfibers for soft tissue repair
Caves, J. M., Cui, W., Wen, J., Kumar, V. A., Haller, C. A., & Chaikof, E. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.009 · Cited by 97
Metadata
- Authors
- Roach, M. R., & Burton, A. C.
- Venue
- Canadian Journal of Biochemistry and Physiology
- Publisher
- Canadian Science Publishing
- Published
- 1957-08-01
- Volume
- 35
- Issue
- 8
- Pages
- 681-690
- ISSN
- 0576-5544 (ISSN-L)
- OpenAlex
- W2128531352
- Cited by
- 790
- References
- 0
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.