AUTOMATED SEIZURE DETECTION USING EKG
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Changes in heart rate, most often increases, are associated with the onset of epileptic seizures and may be used in lieu of cortical activity for automated seizure detection. The feasibility of this aim was tested on 241 clinical seizures from 81 subjects admitted to several Epilepsy Centers for invasive monitoring for evaluation for epilepsy surgery. The performance of the EKG-based seizure detection algorithm was compared to that of a validated algorithm applied to electrocorticogram (ECoG). With the most sensitive detection settings [threshold T: 1.15; duration D: 0 s], 5/241 seizures (2%) were undetected (false negatives) and with the highest [T: 1.3; D: 5 s] settings, the number of false negative detections rose to 34 (14%). The rate of potential false positive (PFP) detections was 9.5/h with the lowest and 1.1/h with the highest T, D settings. Visual review of 336 ECoG segments associated with PFPs revealed that 120 (36%) were associated with seizures, 127 (38%) with bursts of epileptiform discharges and only 87 (26%) were true false positives. Electrocardiographic (EKG)-based seizure onset detection preceded clinical onset by 0.8 s with the lowest and followed it by 13.8 s with the highest T, D settings. Automated EKG-based seizure detection is feasible and has potential clinical utility given its ease of acquisition, processing, high signal/noise and ergonomic advantages viz-a-viz EEG (electroencephalogram) or ECoG. Its use as an "electronic" seizure diary will remedy in part, the inaccuracies of those generated by patients/care-givers in a cost-effective manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural regulation of endocrine and autonomic stress responses
Ulrich-Lai, Y. M., & Herman, J. P. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2647 · Cited by 3,318
The Central Autonomic Network: Functional Organization, Dysfunction, and Perspective
BENARROCH, E. E. (1993) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)62272-1 · Cited by 1,534
Neural mechanisms of autonomic, affective, and cognitive integration
Critchley, H. D. (2005) · Journal of Comparative Neurology · doi:10.1002/cne.20749 · Cited by 1,214
Electrical autonomic correlates of emotion
Sequeira, H., Hot, P., Silvert, L., & Delplanque, S. (2009) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2008.07.009 · Cited by 309
Time-frequency mapping of R-R interval during complex partial seizures of temporal lobe origin.
Novak, V., Reeves, A. L., Novak, P., Low, P. A., & Sharbrough, F. W. (1999) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(99)00044-2 · Cited by 101
Reactivity of Ambulatory Blood Pressure to Physical Activity Varies With Time of Day
Jones, H., Atkinson, G., Leary, A., George, K., Murphy, M., & Waterhouse, J. (2006) · Hypertension · doi:10.1161/01.hyp.0000206421.09642.b5 · Cited by 96
Cited by
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403
Closed-loop Neurostimulation: The Clinical Experience
Sun, F. T., & Morrell, M. J. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0280-3 · Cited by 286
Automated seizure detection systems and their effectiveness for each type of seizure
Ulate-Campos, A., Coughlin, F., Gaínza-Lein, M., Fernández, I. S., Pearl, P. L., & Loddenkemper, T. (2016) · Seizure · doi:10.1016/j.seizure.2016.06.008 · Cited by 233
Computer-Aided Diagnosis of Depression Using EEG Signals
Acharya, U. R., Sudarshan, V. K., Adeli, H., Santhosh, J., Koh, J. E. W., & Adeli, A. (2015) · European Neurology · doi:10.1159/000381950 · Cited by 197
Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment
Vandecasteele, K., De Cooman, T., Gu, Y., Cleeren, E., Claes, K., Paesschen, W., Huffel, S., & Hunyadi, B. (2017) · Sensors · doi:10.3390/s17102338 · Cited by 174
Metadata
- Authors
- OSORIO, I.
- Venue
- International Journal of Neural Systems
- Publisher
- World Scientific Pub Co Pte Ltd
- Published
- 2014-01-29
- Volume
- 24
- Issue
- 02
- Pages
- 1450001
- ISSN
- 0129-0657 (ISSN-L)
- 1793-6462
- OpenAlex
- W1972533436
- Cited by
- 60
- References
- 6
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.