The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Enabling always-available input with muscle-computer interfaces
Abstract
Previous work has demonstrated the viability of applying offline analysis to interpret forearm electromyography (EMG) and classify finger gestures on a physical surface. We extend those results to bring us closer to using muscle-computer interfaces for always-available input in real-world applications. We leverage existing taxonomies of natural human grips to develop a gesture set covering interaction in free space even when hands are busy with other objects. We present a system that classifies these gestures in real-time and we introduce a bi-manual paradigm that enables use in interactive systems. We report experimental results demonstrating four-finger classification accuracies averaging 79% for pinching, 85% while holding a travel mug, and 88% when carrying a weighted bag. We further show generalizability across different arm postures and explore the tradeoffs of providing real-time visual feedback.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Tutorial on Support Vector Machines for Pattern Recognition
Burges, C. J. C. (1998) · Data Mining and Knowledge Discovery · doi:10.1023/a:1009715923555 · Cited by 16,429
A TUTORIAL ON SUPPORT VECTOR MACHINES FOR PATTERN RECOGNITION, DATA MINING AND KNOWLEDGE DISCOVERY
Burger, C. J. C. (1998) · Cited by 3,313
(1998) · Cited by 2,679
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Phidgets: easy development of physical interfaces through physical widgets
Greenberg, S., & Fitchett, C. (2001) · Proceedings of the 14th annual ACM symposium on User interface software and technology · doi:10.1145/502348.502388 · Cited by 652
PlayAnywhere: a compact interactive tabletop projection-vision system
Wilson, A. D. (2005) · Proceedings of the 18th annual ACM symposium on User interface software and technology · doi:10.1145/1095034.1095047 · Cited by 375
MacKenzie, C. L., & Iberall, T. (2011) · Cited by 366
Neuro-Fuzzy Control of a Robotic Exoskeleton With EMG Signals
Kiguchi, K., Tanaka, T., & Fukuda, T. (2004) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2004.832525 · Cited by 364
Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., & Balakrishnan, R. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357138 · Cited by 275
Self-citationMyoelectric teleoperation of a complex robotic hand
Farry, K. A., Walker, I. D., & Baraniuk, R. G. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.538982 · Cited by 248
Using a low-cost electroencephalograph for task classification in HCI research
Lee, J. C., & Tan, D. S. (2006) · Proceedings of the 19th annual ACM symposium on User interface software and technology · doi:10.1145/1166253.1166268 · Cited by 165
Self-citationTowards the Control of Individual Fingers of a Prosthetic Hand Using Surface EMG Signals
Tenore, F. V., Ramos‐Murguialday, A., Fahmy, A., Acharya, S., Etienne‐Cummings, R., & Thakor, N. V. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353752 · Cited by 154
Classification of finger activation for use in a robotic prosthesis arm
Dori Peleg, A., Braiman, E., Yom‐Tov, E., & Inbar, G. F. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806831 · Cited by 126
Wang, G., Wang, Z., Chen, W., & Zhuang, J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0100-y · Cited by 104
Intimate interfaces in action: assessing the usability and subtlety of emg-based motionless gestures
Costanza, E., Inverso, S. A., Allen, R., & Maes, P. (2007) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1240624.1240747 · Cited by 92
Gesture-based control and EMG decomposition
Wheeler, K., Chang, M. H., & Knuth, K. H. (2006) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2006.875418 · Cited by 81
Sassaroli, A., ZHENG, F., Hirshfield, L., Girouard, A., Solovey, E., Jacob, R. J. K., & Fantini, S. (2008) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545808000224 · Cited by 65
Simultaneous, Proportional, Multi-axis Prosthesis Control using Multichannel Surface EMG
Yatsenko, D., McDonnall, D., & Guillory, K. S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353749 · Cited by 54
Augmenting conversations using dual-purpose speech
Lyons, K., Skeels, C., Starner, T. E., Snoeck, C. M., Wong, B. A., & Ashbrook, D. (2004) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/1029632.1029674 · Cited by 43
State-based Classification of Finger Gestures from Electromyographic Signals
Ju, P., Kaelbling, L. P., & Singer, Y. (2000) · Cited by 20
Lakshmipathy, V., Schmandt, C., & Marmasse, N. (2003) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/964696.964701 · Cited by 17
Research works printed but not linked: 3
- 10.1109/CCECE.2004.1345029 · doi:10.1109/ccece.2004.1345029
- Naik , G.R. , Kumar , D.K. , Singh , V.P. & Palaniswami , M. 2006 . Hand gestures for HCI using ICA of EMG . HCSNet Workshop on the Use of Vision in HCI, 67--72 . Naik, G.R., Kumar, D.K., Singh, V.P.&Palaniswami, M. 2006. Hand gestures for HCI using ICA of EMG. HCSNet Workshop on the Use of Vision in HCI, 67--72.
- Schlesinger , G. Der Adechanische Auflau der kunstlichen Glieder . 1919 . Ersatzglieder und Arbeitshilfen, 1. Springer Verlag , Berlin. Schlesinger, G. Der Adechanische Auflau der kunstlichen Glieder. 1919. Ersatzglieder und Arbeitshilfen, 1. Springer Verlag, Berlin.
Cited by
Soli: ubiquitous gesture sensing with millimeter wave radar
Lien, J., Gillian, N., Karagozler, M. E., Amihood, P., Schwesig, C., Olson, E., Raja, H., & Poupyrev, I. (2016) · ACM Transactions on Graphics · doi:10.1145/2897824.2925953 · Cited by 957
“As mobile computing grows, new modes of interaction are emerging and becoming feasible, including touch and touchless gestures using camera-based tracking or capacitive field sensors, voice and gaze input, and a multitude of sensors embedded in various objects, the human body, clothes and environments or distributed a…”
BackgroundEMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
OmniTouch: wearable multitouch interaction everywhere
Harrison, C., Benko, H., & Wilson, A. D. (2011) · Proceedings of the 24th annual ACM symposium on User interface software and technology · doi:10.1145/2047196.2047255 · Cited by 562
Wang, S., Song, J., Lien, J., Poupyrev, I., & Hilliges, O. (2016) · Proceedings of the 29th Annual Symposium on User Interface Software and Technology · doi:10.1145/2984511.2984565 · Cited by 433
Digits: freehand 3D interactions anywhere using a wrist-worn gloveless sensor
Kim, D., Hilliges, O., Izadi, S., Butler, A. D., Chen, J., Oikonomidis, I., & Olivier, P. (2012) · Proceedings of the 25th annual ACM symposium on User interface software and technology · doi:10.1145/2380116.2380139 · Cited by 428
Metadata
- Authors
- Saponas, T. S., Tan, D. S., Morris, D., Balakrishnan, R., Turner, J., & Landay, J. A.
- Venue
- Proceedings of the 22nd annual ACM symposium on User interface software and technology
- Publisher
- ACM
- Published
- 2009-10-04
- Pages
- 167-176
- OpenAlex
- W2141964067
- Cited by
- 328
- References
- 23
- FWCI
- 29.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.