CoChat

Enabling deep-tissue networking for miniature medical devices

Open access
Ma, Yunfei, Luo, Zhihong, Steiger, Christoph, Traverso, Giovanni, Adib, Fadel · 2018 · Proceedings of the 2018 Conference of the ACM Special Interest Group on Data Communication
Cited by 91

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

We present IVN (In-Vivo Networking), a system that enables powering up and communicating with miniature sensors implanted or injected in deep tissues. IVN overcomes fundamental challenges which have prevented past systems from powering up miniature sensors beyond superficial depths. These challenges include the significant signal attenuation caused by bodily tissues and the miniature antennas of the implantable sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/3230543.3230566

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 91

Metadata

Authors
Ma, Y., Luo, Z., Steiger, C., Traverso, G., & Adib, F.
Venue
Proceedings of the 2018 Conference of the ACM Special Interest Group on Data Communication
Publisher
ACM
Published
2018-08-07
Pages
417-431
OpenAlex
W2869395566
Cited by
91
References
8
FWCI
23.70
Type
conference paper
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enabling deep-tissue networking for miniature medical devices. https://app.cochat.ai/papers/10.1145/3230543.3230566
The paper
Ma, Y., Luo, Z., Steiger, C., Traverso, G., & Adib, F. (2018). Enabling deep-tissue networking for miniature medical devices. Proceedings of the 2018 Conference of the ACM Special Interest Group on Data Communication. https://doi.org/10.1145/3230543.3230566

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.