Reagentless, Structure-Switching, Electrochemical Aptamer-Based Sensors
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
The development of structure-switching, electrochemical, aptamer-based sensors over the past ∼10 years has led to a variety of reagentless sensors capable of analytical detection in a range of sample matrices. The crux of this methodology is the coupling of target-induced conformation changes of a redox-labeled aptamer with electrochemical detection of the resulting altered charge transfer rate between the redox molecule and electrode surface. Using aptamer recognition expands the highly sensitive detection ability of electrochemistry to a range of previously inaccessible analytes. In this review, we focus on the methods of sensor fabrication and how sensor signaling is affected by fabrication parameters. We then discuss recent studies addressing the fundamentals of sensor signaling as well as quantitative characterization of the analytical performance of electrochemical aptamer-based sensors. Although the limits of detection of reported electrochemical aptamer-based sensors do not often reach that of gold-standard methods such as enzyme-linked immunosorbent assays, the operational convenience of the sensor platform enables exciting analytical applications that we address. Using illustrative examples, we highlight recent advances in the field that impact important areas of analytical chemistry. Finally, we discuss the challenges and prospects for this class of sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mfold web server for nucleic acid folding and hybridization prediction
Zuker, M. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg595 · Cited by 13,404 · cited 1×
“However, the base-pair programming language of nucleic acids along with the aid of secondary structure prediction software (MFOLD (47, 48)) enable the design of altered aptamer sequences to support reagentless, electrochemical signaling (3, 18, 28, 45, 49–52).”
BackgroundFormation and Structure of Self-Assembled Monolayers
Ulman, A. (1996) · Chemical Reviews · doi:10.1021/cr9502357 · Cited by 7,906 · cited 2×
“Increasing the number of carbons in an alkane thiol chain results in improved monolayer packing as a result of increased van der Waals interactions between neighboring thiols (23).”
BackgroundProtein detection using proximity-dependent DNA ligation assays
Fredriksson, S., Gullberg, M., Jarvius, J., Olsson, C., Pietras, K., Gústafsdóttir, S. M., Östman, A., & Landegren, U. (2002) · Nature Biotechnology · doi:10.1038/nbt0502-473 · Cited by 1,504
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Electrochemical Quantitation of DNA Immobilized on Gold
Steel, A. B., Herne, T. M., & Tarlov, M. J. (1998) · Analytical Chemistry · doi:10.1021/ac980037q · Cited by 1,328 · cited 1×
“Typically the indirect method of measuring the charge consumed relating to nucleic acid associated Ru(NH3), first described by Tarlov and coworkers to quantify unlabeled DNA on a surface, has been the method of choice (42).”
MethodStochastic sensors inspired by biology
Bayley, H., & Cremer, P. S. (2001) · Nature · doi:10.1038/35093038 · Cited by 1,118
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Label‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500989 · Cited by 812 · cited 5×
“Furthermore, because the redox-active reporter is covalently linked to the nucleic acid aptamer, the sensor is reagentless and reversible (5, 7, 14, 18).”
BackgroundInfluentialApplications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788 · cited 1×
“directly address these caveats by providing a list of suggested standards when working with and publishing work using aptamers (70).”
BackgroundRational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Cited by
Rationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
Aptamers 101: aptamer discovery and in vitro applications in biosensors and separations
Yang, L. F., Ling, M., Kacherovsky, N., & Pun, S. H. (2023) · Chemical Science · doi:10.1039/d3sc00439b · Cited by 215
Recent advances in neurotechnologies with broad potential for neuroscience research
Vázquez-Guardado, A., Yang, Y., Bandodkar, A. J., & Rogers, J. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00739-8 · Cited by 202
Electrochemical biosensors based on nucleic acid aptamers
Villalonga, A., Pérez-Calabuig, A. M., & Villalonga, R. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02226-x · Cited by 184
Downs, A. M., & Plaxco, K. W. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01428 · Cited by 175
Chen, S., Fan, S., Qiao, Z., Wu, Z., Lin, B., Li, Z., Riegler, M. A., Wong, M. Y. H., Opheim, A., Korostynska, O., et al. (2025) · Advanced Materials · doi:10.1002/adma.202500412 · Cited by 164
Metadata
- Authors
- Schoukroun-Barnes, L. R., Macazo, F. C., Gutierrez, B., Lottermoser, J., Liu, J., & White, R. J.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2016-06-12
- Volume
- 9
- Issue
- 1
- Pages
- 163-181
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2195854070
- Cited by
- 207
- References
- 58
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.