Reagentless, Structure-Switching, Electrochemical Aptamer-Based Sensors
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
The development of structure-switching, electrochemical, aptamer-based sensors over the past ∼10 years has led to a variety of reagentless sensors capable of analytical detection in a range of sample matrices. The crux of this methodology is the coupling of target-induced conformation changes of a redox-labeled aptamer with electrochemical detection of the resulting altered charge transfer rate between the redox molecule and electrode surface. Using aptamer recognition expands the highly sensitive detection ability of electrochemistry to a range of previously inaccessible analytes. In this review, we focus on the methods of sensor fabrication and how sensor signaling is affected by fabrication parameters. We then discuss recent studies addressing the fundamentals of sensor signaling as well as quantitative characterization of the analytical performance of electrochemical aptamer-based sensors. Although the limits of detection of reported electrochemical aptamer-based sensors do not often reach that of gold-standard methods such as enzyme-linked immunosorbent assays, the operational convenience of the sensor platform enables exciting analytical applications that we address. Using illustrative examples, we highlight recent advances in the field that impact important areas of analytical chemistry. Finally, we discuss the challenges and prospects for this class of sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mfold web server for nucleic acid folding and hybridization prediction
Zuker, M. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg595 · Cited by 13,404 · cited 1×
“However, the base-pair programming language of nucleic acids along with the aid of secondary structure prediction software (MFOLD (47, 48)) enable the design of altered aptamer sequences to support reagentless, electrochemical signaling (3, 18, 28, 45, 49–52).”
BackgroundFormation and Structure of Self-Assembled Monolayers
Ulman, A. (1996) · Chemical Reviews · doi:10.1021/cr9502357 · Cited by 7,906 · cited 2×
“Increasing the number of carbons in an alkane thiol chain results in improved monolayer packing as a result of increased van der Waals interactions between neighboring thiols (23).”
BackgroundProtein detection using proximity-dependent DNA ligation assays
Fredriksson, S., Gullberg, M., Jarvius, J., Olsson, C., Pietras, K., Gústafsdóttir, S. M., Östman, A., & Landegren, U. (2002) · Nature Biotechnology · doi:10.1038/nbt0502-473 · Cited by 1,504
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Electrochemical Quantitation of DNA Immobilized on Gold
Steel, A. B., Herne, T. M., & Tarlov, M. J. (1998) · Analytical Chemistry · doi:10.1021/ac980037q · Cited by 1,328 · cited 1×
“Typically the indirect method of measuring the charge consumed relating to nucleic acid associated Ru(NH3), first described by Tarlov and coworkers to quantify unlabeled DNA on a surface, has been the method of choice (42).”
MethodStochastic sensors inspired by biology
Bayley, H., & Cremer, P. S. (2001) · Nature · doi:10.1038/35093038 · Cited by 1,118
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Label‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500989 · Cited by 812 · cited 5×
“Furthermore, because the redox-active reporter is covalently linked to the nucleic acid aptamer, the sensor is reagentless and reversible (5, 7, 14, 18).”
BackgroundInfluentialApplications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788 · cited 1×
“directly address these caveats by providing a list of suggested standards when working with and publishing work using aptamers (70).”
BackgroundRational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Resistive-Pulse SensingFrom Microbes to Molecules
Bayley, H., & Martin, C. R. (2000) · Chemical Reviews · doi:10.1021/cr980099g · Cited by 526
Xiao, Y., Lai, R. Y., & Plaxco, K. W. (2007) · Nature Protocols · doi:10.1038/nprot.2007.413 · Cited by 439 · cited 1×
“The majority of E-AB sensors employ the reversible redox couples methylene blue (1, 10, 27, 28) or ferrocene (9, 10, 16) as the redox-active tag and each molecule offers different advantages and disadvantages (10, 16).”
BackgroundReal-Time, Aptamer-Based Tracking of Circulating Therapeutic Agents in Living Animals
Ferguson, B. S., Hoggarth, D. A., Maliniak, D., Ploense, K., White, R. J., Woodward, N., Hsieh, K., Bonham, A. J., Eisenstein, M., Kippin, T. E., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007095 · Cited by 419 · cited 5×
“The microfluidic-based electrochemical sensing platform, termed as MEDIC (microfluidic electrochemical detector for in vivo continuous monitoring), detected therapeutic in vivo concentrations of doxorubicin and kanamycin in live rats and in human whole blood with high sensitivity and sub-minute temporal resolution (17…”
BackgroundMethodInfluentialSelf-citationAn RNA Aptamer-Based Electrochemical Biosensor for Detection of Theophylline in Serum
Ferapontova, E. E., Olsen, E. M., & Gothelf, K. V. (2008) · Journal of the American Chemical Society · doi:10.1021/ja711326b · Cited by 364 · cited 6×
“There are counter examples, like the RNA theophylline aptamer that will bind theophylline with a 500-fold better affinity than caffeine even though the targets differ by only a single methyl group (16).”
BackgroundInfluentialWhite, R. J., Phares, N., Lubin, A. A., Xiao, Y., & Plaxco, K. W. (2008) · Langmuir · doi:10.1021/la800801v · Cited by 358 · cited 7×
“The latter can significantly alter the observed binding affinity (Kd) of the sensor (2, 25).”
BackgroundInfluentialSelf-citationLabel-Free and Reagentless Aptamer-Based Sensors for Small Molecules
Zayats, M., Huang, Y., Gill, R., Ma, C., & Willner, I. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0651456 · Cited by 337
Effect of Molecular Crowding on the Response of an Electrochemical DNA Sensor
Ricci, F., Lai, R. Y., Heeger, A. J., Plaxco, K. W., & Sumner, J. J. (2007) · Langmuir · doi:10.1021/la700328r · Cited by 334 · cited 2×
“Values reported for aptamer packing density range from ~1011–1013 aptamers/cm2 (2, 25).”
BackgroundAptamer-Based Electrochemical Biosensor for Interferon Gamma Detection
Liu, Y., Tuleouva, N., Ramanculov, E., & Revzin, A. (2010) · Analytical Chemistry · doi:10.1021/ac101409t · Cited by 324 · cited 2×
“For example, Plaxco’s, Heeger’s, and Revzin’s groups reported a general electrochemical sensing platform for the detection of the proteins thrombin (14), platelet-derived growth factor (PDGF) (1), INF-γ (61), and botulism toxin (52) in buffer and in serum.”
BackgroundInfluence of ionic strength, pH and aptamer configuration for binding affinity to thrombin
Hianik, T., Ostatná, V., Sonlajtnerova, M., & Grman, I. (2007) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.03.012 · Cited by 320
Protein Detection by Nanopores Equipped with Aptamers
Rotem, D., Jayasinghe, L., Salichou, M., & Bayley, H. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2105653 · Cited by 312 · cited 3×
“demonstrated nanomolar (nM) sensitivity of an aptamer-based nanopore sensor via the utility of staphylococcal αhemolysin (αHL) modified with a 15-mer DNA aptamer that specifically binds thrombin (67).”
BackgroundElectrochemical Analysis of Neurotransmitters
Bucher, E. S., & Wightman, R. M. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040426 · Cited by 298
Specific binding of aminoglycoside antibiotics to RNA
Wang, Y., & Rando, R. R. (1995) · Chemistry & Biology · doi:10.1016/1074-5521(95)90047-0 · Cited by 227 · cited 2×
“sequences to undergo larger conformation changes in the presence of tobramycin (28, 54).”
BackgroundComprehensive Analytical Comparison of Strategies Used for Small Molecule Aptamer Evaluation
McKeague, M., Girolamo, A. D., Valenzano, S., Pascale, M., Ruscito, A., Velu, R., Frost, N. R., Hill, K., Smith, M., McConnell, E. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02102 · Cited by 210 · cited 1×
“highlights inconsistencies in quantification of aptamer binding parameters as a result of different assays used to perform the characterization (74).”
MethodSolid Contact Potentiometric Sensors for Trace Level Measurements
Chumbimuni-Torres, K. Y., Rubinova, N., Radu, A., Kubota, L. T., & Bakker, E. (2006) · Analytical Chemistry · doi:10.1021/ac050749y · Cited by 206
Connell, T. G. (2006) · Thorax · doi:10.1136/thx.2005.048033 · Cited by 199
Solution structure of the tobramycin–RNA aptamer complex
Jiang, L., & Patel, D. J. (1998) · Nature Structural Biology · doi:10.1038/1804 · Cited by 187 · cited 1×
“For example, we recently published a report that utilized a combination of secondary structure predictions and the NMR structure of the aminoglycoside-binding RNA aptamer (53) to rationally design”
MethodZhang, S., Xia, J., & Li, X. (2008) · Analytical Chemistry · doi:10.1021/ac800857p · Cited by 186
Using reliability information to annotate RNA secondary structures
ZUKER, M., & JACOBSON, A. B. (1998) · RNA · doi:10.1017/s1355838298980116 · Cited by 178
Nanoelectrodes: Recent Advances and New Directions
Cox, J. T., & Zhang, B. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143124 · Cited by 177 · cited 1×
“Electrode Miniaturization—Coupling E-AB sensors to micro- and nanoelectrodes has the ability to bring the promising attributes of small electrodes - low IR drop, small background capacitive charging current, rapid steady-state equilibration, high current density, and minimal sample requirement (80) – with aptamer reco…”
BackgroundPorchetta, A., Vallée‐Bélisle, A., Plaxco, K. W., & Ricci, F. (2012) · Journal of the American Chemical Society · doi:10.1021/ja310585e · Cited by 173
Chang, A. L., McKeague, M., Liang, J. C., & Smolke, C. D. (2014) · Analytical Chemistry · doi:10.1021/ac5001527 · Cited by 159 · cited 1×
“Reports indicate that association rate constants range from ~103– 105 M−1s−1 and dissociation rates range between ~10−2–10−3 s−1 for small molecule binding (33, 34).”
BackgroundAnne, A., & Demaille, C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja055112a · Cited by 158
DNA Electrochemistry with Tethered Methylene Blue
Pheeney, C. G., & Barton, J. K. (2012) · Langmuir · doi:10.1021/la300566x · Cited by 153
Liu, Y., Kwa, T., & Revzin, A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.089 · Cited by 141 · cited 2×
“For example, protein-binding aptamers, including thrombin, interferon gamma, and tumor necrosis factor alpha exemplify target specificity in complex media and when challenged by similar proteins (8, 14, 62).”
BackgroundDetecting multiple cell-secreted cytokines from the same aptamer-functionalized electrode
Liu, Y., Liu, Y., Matharu, Z., Rahimian, A., & Revzin, A. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.034 · Cited by 140 · cited 3×
“Several other oligonucleotide-bound redox markers have been employed, such as iron oxide particles (32) and anthraquinones (35), but have seen less widespread use.”
BackgroundMethodAn aptasensor for electrochemical detection of tumor necrosis factor in human blood
Liu, Y., Zhou, Q., & Revzin, A. (2013) · The Analyst · doi:10.1039/c3an00818e · Cited by 136 · cited 4×
“To date, aptamer-based sensors have been tested in a variety of complex media, including foodstuffs (55), undiluted serum (1, 4, 7), saliva (18, 55), whole blood (8, 50), and real-time in the circulating blood of living animals (17).”
BackgroundInfluentialLi, T., Liu, L., Li, Y., Xie, J., & Wu, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201502047 · Cited by 116 · cited 1×
“Coined as aptamer-based nanopores, studies to date demonstrate the detection of various targets, such as proteins (67) and biomarkers (68, 69).”
BackgroundSurface chemistry effects on the performance of an electrochemical DNA sensor
Ricci, F., Zari, N., Caprio, F., Recine, S., Amine, A., Moscone, D., Palleschi, G., & Plaxco, K. W. (2009) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2009.03.007 · Cited by 106 · cited 1×
“demonstrated that sensor performance improved for both positively (amineterminated thiols) and negatively charged (sulfonic acid-terminated thiols) monolayers (24).”
BackgroundLiu, J., Wagan, S., Morris, M. D., Taylor, J., & White, R. J. (2014) · Analytical Chemistry · doi:10.1021/ac503407e · Cited by 105 · cited 4×
“reported the first reversible and reproducible use of microelectrodes for E-AB sensing for the detection of ATP and tobramycin quantification directly in 100% undiluted serum (5).”
BackgroundInfluentialSelf-citationBlouin, S., & Lafontaine, D. A. (2007) · RNA · doi:10.1261/rna.560307 · Cited by 99 · cited 1×
“Examples include the dependence of the G-quadruplex motif on K+ ions (51), as well as the K-turn (kink turn) motif on Mg2+ ions (57).”
BackgroundDeterminants of the Detection Limit and Specificity of Surface-Based Biosensors
de Ávila, B. E., Watkins, H. M., Pingarrón, J. M., Plaxco, K. W., Palleschi, G., & Ricci, F. (2013) · Analytical Chemistry · doi:10.1021/ac4012123 · Cited by 97
Nanomolar Detection Limits of Cd2+, Ag+, and K+ Using Paper-Strip Ion-Selective Electrodes
Mensah, S. T., Gonzalez, Y., Calvo‐Marzal, P., & Chumbimuni‐Torres, K. Y. (2014) · Analytical Chemistry · doi:10.1021/ac501470p · Cited by 93
Re-engineering aptamers to support reagentless, self-reporting electrochemical sensors
White, R., Rowe, A. A., & Plaxco, K. (2010) · In Analysis · doi:10.1039/b921253a · Cited by 89
Self-citationMatharu, Z., Patel, D., Gao, Y., Haque, A., Zhou, Q., & Revzin, A. (2014) · Analytical Chemistry · doi:10.1021/ac502383e · Cited by 85 · cited 1×
“redox-active DNA aptamers specific for their respective targets and integration with a microfluidic device (35, 62, 63).”
BackgroundStudies of temperature-dependent electronic transduction on DNA hairpin loop sensor
Mao, Y., Luo, C., & Ouyang, Q. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng108 · Cited by 84 · cited 1×
“There are several other reports that address the affects of pH and temperature on nucleic acid-based sensors (72, 73).”
BackgroundNMR Chemical Exchange as a Probe for Ligand-Binding Kinetics in a Theophylline-Binding RNA Aptamer
Latham, M. P., Zimmermann, G. R., & Pardi, A. (2009) · Journal of the American Chemical Society · doi:10.1021/ja900695m · Cited by 84 · cited 1×
“Reports indicate that association rate constants range from ~103– 105 M−1s−1 and dissociation rates range between ~10−2–10−3 s−1 for small molecule binding (33, 34).”
BackgroundNanoscale Spatial Distribution of Thiolated DNA on Model Nucleic Acid Sensor Surfaces
Josephs, E. A., & Ye, T. (2013) · ACS Nano · doi:10.1021/nn400659m · Cited by 82
Ferapontova, E. E., & Gothelf, K. V. (2009) · Electroanalysis · doi:10.1002/elan.200804558 · Cited by 81 · cited 4×
“The covalent coupling of methylene blue is typically achieved by reacting a 3′-amine-terminated nucleic acid with n-hydroxysuccinimide esteractivated methylene blue (29).”
BackgroundInfluentialMicroelectrode miRNA Sensors Enabled by Enzymeless Electrochemical Signal Amplification
Wang, T., Viennois, É., Merlin, D., & Wang, G. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00780 · Cited by 73 · cited 1×
“These advantages open up E-AB sensor applications to new areas of biological and chemical sensing (5, 81), such as scanning electrochemical microscopy (SECM) for spatially-resolved measurements (82).”
BackgroundUzawa, T., Cheng, R. R., White, R. J., Makarov, D. E., & Plaxco, K. W. (2010) · Journal of the American Chemical Society · doi:10.1021/ja106345d · Cited by 71
Self-citationLugo‐Morales, L. Z., Loziuk, P. L., Corder, A. K., Toups, J. V., Roberts, J. G., McCaffrey, K. A., & Sombers, L. A. (2013) · Analytical Chemistry · doi:10.1021/ac4017852 · Cited by 65
Label-Free Nanopore Proximity Bioassay for Platelet-Derived Growth Factor Detection
Zhang, L., Zhang, K., Liu, G., Liu, M., Liu, Y., & Li, J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00791 · Cited by 63
The Current and Future Role of Aptamers in Electroanalysis
Liu, J., Morris, M. D., Macazo, F. C., Schoukroun-Barnes, L. R., & White, R. J. (2014) · Journal of The Electrochemical Society · doi:10.1149/2.026405jes · Cited by 62
Self-citationHuang, K.-C., & White, R. J. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4060788 · Cited by 58
Self-citationPlatinized carbon nanoelectrodes as potentiometric and amperometric SECM probes
Hu, K., Gao, Y., Wang, Y., Yu, Y., Zhao, X., Rotenberg, S. A., Gökmeşe, E., Mirkin, M. V., Friedman, G., & Gogotsi, Y. G. (2013) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-013-2173-5 · Cited by 54
Miao, P., Tang, Y., Wang, B., Han, K., Chen, X., & Sun, H. (2014) · The Analyst · doi:10.1039/c4an01350f · Cited by 45
Zhang, S., Zhou, G., Xu, X., Cao, L., Liang, G., Chen, H., Liu, B., & Kong, J. (2011) · Electrochemistry Communications · doi:10.1016/j.elecom.2011.06.002 · Cited by 31 · cited 2×
“Several other oligonucleotide-bound redox markers have been employed, such as iron oxide particles (32) and anthraquinones (35), but have seen less widespread use.”
BackgroundRationally Designing Aptamer Sequences with Reduced Affinity for Controlled Sensor Performance
Schoukroun-Barnes, L. R., & White, R. J. (2015) · Sensors · doi:10.3390/s150407754 · Cited by 18 · cited 2×
“Typical strategies include destabilization of any secondary structure, generating alternative folds of the aptamer, and the introduction of the aptamer into a scaffold (3, 28, 45, 49, 52).”
BackgroundSelf-citation
Cited by
Rationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
Aptamers 101: aptamer discovery and in vitro applications in biosensors and separations
Yang, L. F., Ling, M., Kacherovsky, N., & Pun, S. H. (2023) · Chemical Science · doi:10.1039/d3sc00439b · Cited by 215
Recent advances in neurotechnologies with broad potential for neuroscience research
Vázquez-Guardado, A., Yang, Y., Bandodkar, A. J., & Rogers, J. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00739-8 · Cited by 202
Electrochemical biosensors based on nucleic acid aptamers
Villalonga, A., Pérez-Calabuig, A. M., & Villalonga, R. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02226-x · Cited by 184
Downs, A. M., & Plaxco, K. W. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01428 · Cited by 175
Metadata
- Authors
- Schoukroun-Barnes, L. R., Macazo, F. C., Gutierrez, B., Lottermoser, J., Liu, J., & White, R. J.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2016-06-12
- Volume
- 9
- Issue
- 1
- Pages
- 163-181
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2195854070
- Cited by
- 207
- References
- 58
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.