Analytical Approaches for Size and Mass Analysis of Large Protein Assemblies
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Analysis of the size and mass of nanoparticles, whether they are natural biomacromolecular or synthetic supramolecular assemblies, is an important step in the characterization of such molecular species. In recent years, electrospray ionization (ESI) has emerged as a technology through which particles with masses up to 100 MDa can be ionized and transferred into the gas phase, preparing them for accurate mass analysis. Here we review currently used methodologies, with a clear focus on native mass spectrometry (MS). Additional complementary methodologies are also covered, including ion-mobility analysis, nanomechanical mass sensors, and charge-detection MS. The literature discussed clearly demonstrates the great potential of ESI-based methodologies for the size and mass analysis of nanoparticles, including very large naturally occurring protein assemblies. The analytical approaches discussed are powerful tools in not only structural biology, but also nanotechnology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proteome survey reveals modularity of the yeast cell machinery
Gavin, A.-C., Aloy, P., Grandi, P., Krause, R., Boesche, M., Marzioch, M., Rau, C., Jensen, L. J., Bastuck, S., Dümpelfeld, B., et al. (2006) · Nature · doi:10.1038/nature04532 · Cited by 2,575
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Mass spectrometry of intact membrane protein complexes
Laganowsky, A., Reading, E., Hopper, J. T. S., & Robinson, C. V. (2013) · Nature Protocols · doi:10.1038/nprot.2013.024 · Cited by 409
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392 · cited 5×
“The resolving power of the technique is often sufficient to monitor posttranslational modifications (such as glycosylation and phosphorylation) and small ligand binding on intact protein complexes up to the megadalton range (18, 58, 61).”
InfluentialSelf-citationHall, Z., Politis, A., Bush, M. F., Smith, L. J., & Robinson, C. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2096859 · Cited by 267 · cited 1×
“Depending on precursor ion charge and the quaternary structure of the protein complex, alternative dissociation pathways may also be observed that include the dissociation of lower-charged compact subunits, dissociation of higher-order multimers from a complex or fragmentation of the peptide backbone (15).”
Interrogating viral capsid assembly with ion mobility–mass spectrometry
Uetrecht, C., Barbu, I. M., Shoemaker, G. K., van Duijn, E., & Heck, A. J. R. (2011) · Nature Chemistry · doi:10.1038/nchem.947 · Cited by 267
Self-citationDynamics of ions of intact proteins in the Orbitrap mass analyzer
Makarov, A., & Denisov, E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.024 · Cited by 194 · cited 1×
“More recently, Makarov and coworkers (58, 96) have shown that single-ion detection can also be achieved for highly charged proteins and protein assemblies using Orbitrap mass analyzers.”
Mass spectrometry supported determination of protein complex structure
Walzthoeni, T., Leitner, A., Stengel, F., & Aebersold, R. (2013) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2013.02.008 · Cited by 146
Allosteric mechanisms can be distinguished using structural mass spectrometry
Dyachenko, A., Gruber, R., Shimon, L., Horovitz, A., & Sharon, M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1302395110 · Cited by 144 · cited 3×
“EDDA was recently introduced and shown to be particularly suitable for the analysis of the ATP-binding GroEL chaperone, resulting in very good desolvation and high-mass resolving power (18).”
Probing the biophysical interplay between a viral genome and its capsid
Snijder, J., Uetrecht, C., Rose, R. J., Sanchez-Eugenia, R., Marti, G. A., Agirre, J., Guérin, D. M. A., Wuite, G. J. L., Heck, A. J. R., & Roos, W. H. (2013) · Nature Chemistry · doi:10.1038/nchem.1627 · Cited by 127 · cited 1×
“These diameters can be converted to a mass spectrum as well, due to the generally good correlation between mobility size and molecular weight, although as in IMMS, exceptions to this rule may apply for nonglobular structures, such as shell-like viral capsid intermediates (66, 112).”
Self-citationHedges, J. B., Vahidi, S., Yue, X., & Konermann, L. (2013) · Analytical Chemistry · doi:10.1021/ac401020s · Cited by 109 · cited 1×
“Ammonium bicarbonate has a higher buffer capacity but may cause protein unfolding at the gas-water interface introduced by bubble formation of the CO2 gas (17).”
Blackwell, A. E., Dodds, E. D., Bandarian, V., & Wysocki, V. H. (2011) · Analytical Chemistry · doi:10.1021/ac200452b · Cited by 84
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Self-citationThe diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
Self-citationMass Spectrometry of Protein Complexes: From Origins to Applications
Mehmood, S., Allison, T. M., & Robinson, C. V. (2015) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040214-121732 · Cited by 199
“In contrast to Q-TOF mass spectrometers, increased pressure within the source region showed no significant effect on ion transmission (61, 62).”
BackgroundComprehensive Overview of Bottom-Up Proteomics Using Mass Spectrometry
Jiang, Y., Rex, D. A. B., Schuster, D., Neely, B. A., Rosano, G. L., Volkmar, N., Momenzadeh, A., Peters-Clarke, T. M., Egbert, S. B., Kreimer, S., et al. (2024) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.3c00068 · Cited by 190
Wörner, T. P., Snijder, J., Bennett, A., Agbandje-McKenna, M., Makarov, A. A., & Heck, A. J. R. (2020) · Nature Methods · doi:10.1038/s41592-020-0770-7 · Cited by 186
Self-citation
Metadata
- Authors
- Snijder, J., & Heck, A. J. R.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2014-06-12
- Volume
- 7
- Issue
- 1
- Pages
- 43-64
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2111455978
- Cited by
- 70
- References
- 12
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.