Bone Mechanical Properties in Healthy and Diseased States
Open accessThe DOI matches its Crossref record; 173 of the 174 references it cites were found in a registry or an index; 47 of the 225 sources its claims cite were checked for support.
Abstract
Review of bone mechanics across length scales, including cortical bone, trabecular bone, and whole bones, covering elasticity, yield, fracture, fatigue, and damage.
Overview
CoChat Summary
TL;DR
This review synthesizes current knowledge of bone mechanical behavior from the nanoscale to whole-bone scale in healthy, aging, and diseased states. It emphasizes porosity/bone quantity and bone-quality parameters such as cross-linking and protein composition as determinants of cortical, trabecular, and whole-bone stiffness, strength, toughness, fatigue, and damage.
Key findings
- Cortical bone has 5–15% porosity and trabecular bone 40–95%; cortical bone is anisotropic, strongest in longitudinal compression and weakest in transverse tension, with mode I fracture toughness \(K_{IC}\) of 2–6 MPa√m, lower for longitudinal than transverse fracture and lower at high strain rates.
- With aging, cortical tensile/compressive strength declines ~2% per decade from the third decade, tensile ultimate strain declines ~10% per decade from 5% at age 20–30 to <1% above age 80, and fracture toughness declines ~4% per decade; trabecular modulus and strength decline ~10% per decade, and proximal femoral strength declines ~10–12% per decade (~50% from early to late adulthood).
- Human trabecular bone apparent modulus ranges from 10 to 3,000 MPa and strength from 0.1 to 30 MPa; 70–90% of the variance in modulus and strength is explained by volume fraction or apparent density, with power-law exponents of ~2–3 for modulus and ~2 for compressive strength.
- Bone quality matters: nonenzymatic glycation cross-links are associated with increased brittleness, diabetes is associated with lower bone toughness and possibly heightened AGE accumulation, and long-term antiresorptive therapy is associated with decreased toughness.
Methods
- Narrative review of bone mechanics across length scales from hundreds of nanometers to tens of centimeters, covering cortical bone, trabecular bone, whole bones, and material behaviors including elasticity, yield, fracture, fatigue, and damage.
- No primary data collection or systematic search/meta-analysis is described; the review synthesizes in vitro, in vivo, imaging, analytical, and finite element modeling literature.
- It discusses bone quantity (density, porosity) and bone quality (cross-linking, protein composition) and identifies future research avenues.
Limitations
- Stated in the paper: no consensus exists on the most accurate multiaxial yield criterion for trabecular bone, largely because none has been validated with an independent set of specimens; few data are available on whether aging or disease affect trabecular tissue differently than cortical tissue; the mechanistic link between microdamage and increased fracture risk has not been established; and consensus has yet to emerge on Raman spectroscopy readouts as indicators of bone fragility.
- Evident from the text: as a narrative review, it does not report a systematic search strategy, inclusion criteria, or quantitative synthesis, and its conclusions draw on heterogeneous ex vivo, animal, and modeling studies.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
43 Valid · 4 Not valid · 117 Not checked · 68 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“In vitro mechanical tests have found that microdamage is associated with a decrease in modulus (9, 10)”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Not checked — no full text of the sourcecites [9] Burr DB Turner CH Naick P Forwood MR Ambrosius W 1998 Does microdamage accumulation affect the mechanical properties of bone? J Biomech 31 337 45 9672087 source
- Supportedcites [10] Nicolella DP Ni Q Chan KS 2011 Non-destructive characterization of microdamage in cortical bone using low field pulsed NMR J Mech Behav Biomed Mater 4 383 91 21316626 PMC3073569 source
The Introduction states that microdamage has been directly associated with modulus degradation. The Results compare measured and predicted elastic-modulus degradation in cyclically damaged cortical bone, and the Conclusions say the relationship agrees with experimental observations. Page numbers are not supplied in our copy. (LLM, conf=0.94)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“Preliminary values of fracture toughness at the microscale appear to be similar to those measured at the macroscale (41).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [41] Kataruka A Mendu K Okeoghene O Puthuvelil J Akono AT 2017 Microscopic assessment of bone toughness using scratch tests Bone Rep 6 17 25 28377977 PMC5365275 source
The Results & discussion section (“Fracture characteristics”) reports microscale scratch-test toughness values of 3.15 ± 0.56 and 3.49 ± 0.80 MPa√m. It explicitly says these fall within the 2.2–4.6 MPa√m range reported for macroscopic fracture tests. (LLM, conf=0.94)
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“and that this difference may be related to heightened accumulation of AGEs in diabetic bone (75).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [75] Rubin MR Paschalis EP Poundarik A Sroga GE McMahon DJ 2016 Advanced glycation endproducts and bone material properties in type 1 diabetic mice PLOS ONE 11 e0154700 27140650 PMC4854398 source
The Abstract reports increased skeletal AGEs and lower bone toughness in a type 1 diabetic mouse model, with higher AGEs correlating with lower macroscopic toughness. The Discussion likewise says AGE accumulation co-exists with bone deterioration, supporting the claim’s tentative wording. (LLM, conf=0.91)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“and there is concern that long-term use of antiresorptive therapies can result in decreased toughness (48, 72, 73).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [48] Lloyd AA Gludovatz B Riedel C Luengo EA Saiyed R 2017 Atypical fracture with long-term bisphosphonate therapy is associated with altered cortical composition and reduced fracture resistance PNAS 114 8722 27 28760963 PMC5565436 source
The Conclusion states that long-term antiresorptive treatment can affect bone toughness through reductions in intrinsic and extrinsic toughening mechanisms. The Loss of Intrinsic Toughening section reports reduced fracture toughness in cortical bone from bisphosphonate-treated patients, supporting the citing sentence’s hedged concern. (LLM, conf=0.92)
- Supportedcites [72] Allen MR Burr DB 2011 Bisphosphonate effects on bone turnover, microdamage, and mechanical properties: what we think we know and what we know that we don’t know Bone 49 56 65 20955825 source
The mechanical-properties discussion (page not provided) says bisphosphonate treatment consistently reduces bone toughness and that toughness declines with longer treatment. The paper discusses this as a concern, while noting that whether the change occurs in human bone remains to be determined. (LLM, conf=0.90)
- Not checked — no full text of the sourcecites [73] Chapurlat RD Delmas PD 2009 Bone microdamage: a clinical perspective Osteoporos Int 20 1299 308 19291343 source
plainstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“The mechanical effects of osteoporosis therapies, however, differ among the types of therapy (70, 71)”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Not checked — no full text of the sourcecites [70] Campbell GM Tiwari S Picke AK Hofbauer C Rauner M 2016 Effects of insulin therapy on porosity, non-enzymatic glycation and mechanical competence in the bone of rats with type 2 diabetes mellitus Bone 91 186 93 27497735 source
- Supportedcites [71] Brock GR Chen JT Ingraffea AR MacLeay J Pluhar GE 2015 The effect of osteoporosis treatments on fatigue properties of cortical bone tissue Bone Rep 2 8 13 25642445 PMC4306187 source
The Discussion and conclusions state that differences in cortical bone fatigue life depended on treatment class and drug: alendronate reduced fatigue life, PTH increased it, and raloxifene and zoledronate did not change it. This supports the cited claim that mechanical effects differ among osteoporosis therapies. (LLM, conf=0.93)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
165 more claims · 23 with their cited sources checked
Create a free account to see all 232 claims and to verify the 14 references still open.
- Probably not a substantial claim. 25
- It may state two separate claims as one. 41
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
“When loaded in tension along the longitudinal direction, cortical bone exhibits a bilinear stress–strain response in which a distinct yield point separates a linearly elastic region and a region of linear hardening that ends abruptly at a fracture strain of less than 3% (Figure 1a).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
“Tensile ultimate strain decreases by approximately 10% per decade, from a high of 5% strain at age 20–30 years to a low of less than 1% strain above age 80 years.”
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303 · cited 1×
“Measures of trabecular architecture include trabecular thickness, trabecular spacing, trabecular number, connectivity density, structure model index (SMI; a measure of how rod-like versus plate-like the architecture is), and the degree of anisotropy (83).”
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283 · cited 1×
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209 · cited 3×
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
Self-citationComparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142 · cited 1×
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
Self-citationBiomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961 · cited 1×
“Using this approach, investigators attributed the experimentally observed dependence of Young’s modulus and compressive strength on apparent density raised to the second power to bendingdominated linear elastic behavior and failure by buckling (127).”
Riggs, B. L., Melton, L. J., Robb, R. A., Camp, J. J., Atkinson, E. J., Peterson, J. M., Rouleau, P. A., McCollough, C. H., Bouxsein, M. L., & Khosla, S. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040916 · Cited by 925 · cited 2×
“For the vertebrae, an increase in the cross-sectional area with aging has been reported for both men and women (154), and one study found that this increase was three times greater in men than in women (158).”
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924 · cited 1×
“Elastic moduli measured by nanoindentation are on the order of 23 GPa and 26 GPa for osteonal and interstitial lamellae, respectively, in the longitudinal direction (36, 37), and are approximately 45% lower in the transverse direction (37).”
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Cited by
Items 101–200 of 1,021
A review on in vitro / in vivo response of additively manufactured Ti–6Al–4V alloy
Alipour, S., Nour, S., Attari, S., Mohajeri, M., Kianersi, S., Taromian, F., Khalkhali, M., Aninwene, G. E., & Tayebi, L. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb01616h · Cited by 46
Review on Biocompatibility and Prospect Biomedical Applications of Novel Functional Metallic Glasses
Biały, M., Hasiak, M., & Łaszcz, A. (2022) · Journal of Functional Biomaterials · doi:10.3390/jfb13040245 · Cited by 42
Krobot, Š., Melčová, V., Menčík, P., Kontárová, S., Rampichová, M., Hedvičáková, V., Mojžišová, E., Baco, A., & Přikryl, R. (2023) · Polymers · doi:10.3390/polym15102404 · Cited by 47
“1–30 MPa, depending on the bone type, its location in the body, and the orientation of applied stress [41].”
BackgroundLadani, L. J., & Palmieri, M. (2024) · Metals · doi:10.3390/met14091039 · Cited by 53
Porous PEDOT:PSS Particles and their Application as Tunable Cell Culture Substrate
Rauer, S. B., Bell, D. J., Jain, P., Rahimi, K., Felder, D., Linkhorst, J., & Weßling, M. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100836 · Cited by 38
Ouldyerou, A., Merdji, A., Aminallah, L., et al. (2022) · International Journal for Multiscale Computational Engineering · doi:10.1615/intjmultcompeng.2022043707 · Cited by 39
An overview of translational research in bone graft biomaterials
Kumawat, V. S., Bandyopadhyay‐Ghosh, S., & Ghosh, S. B. (2022) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2022.2127143 · Cited by 42
“Bone, mainly divided into two types, namely cortical bone and cancellous bone [46,47].”
BackgroundMinocycline-induced disruption of the intestinal FXR/FGF15 axis impairs osteogenesis in mice
Carson, M. D., Warner, A. J., Hathaway‐Schrader, J. D., Geiser, V. L., Kim, J., Gerasco, J. E., Hill, W., Lemasters, J. J., Alekseyenko, A. V., Wu, Y. R., et al. (2023) · JCI Insight · doi:10.1172/jci.insight.160578 · Cited by 42
“11 are an important determinant of bone strength(70-72), the impaired fracture resistance observed in 12-week-old 1 minocycline-treated female SPF mice appears to be attributed to inferior trabecular bone properties.”
The development of magnesium‐based biomaterials in bone tissue engineering: A review
Wu, J., Cheng, X., Wu, J., Chen, J., & Pei, X. (2023) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35326 · Cited by 45
Frank, M., Reisinger, A., Andriotis, O. G., Pahr, D. H., & Thurner, P. J. (2024) · JBMR Plus · doi:10.1093/jbmrpl/ziae049 · Cited by 53
“17 At the micro-scale (micrometer-sized specimens, level of bone lamellae) mechanical properties of trabecular 18–21 and cortical 19,21,22 bone tissue were only minorly (mostly not significant) changed in osteoporosis.”
BackgroundMultiscale and multidisciplinary analysis of aging processes in bone
Ravazzano, L., Colaianni, G., Tarakanova, A., Xiao, Y.-B., Grano, M., & Libonati, F. (2024) · npj Aging · doi:10.1038/s41514-024-00156-2 · Cited by 42
“In some cases, a multiscale approach has been adopted 7 – 10 , butkeeping thefocusonaspeci fi ctopicrelatedtoboneaging 7,8 , or using a speci fi c technique 10 .”
BackgroundMethodInfluentialAlumina and Zirconia-Reinforced Polyamide PA-12 Composites for Biomedical Additive Manufacturing
Nakonieczny, D. S., Kern, F., Dufner, L., et al. (2021) · Materials · doi:10.3390/ma14206201 · Cited by 38
“For the femoral cortical bone, the following mechanical values/ranges have been observed [7]: (I) in the longitudinal direction, an elastic modulus of 17,900 ± 3900 MPa; (II) in the transverse direction, an elastic modulus of 10,100 ± 2400 MPa.”
MethodInfluentialOsteocyte β1 integrin loss causes low bone mass and impairs bone mechanotransduction in mice
Qin, L., He, T., Yang, D., Wang, Y., Li, Z., Yan, Q., Zhang, P., Chen, Z., Lin, S., Gao, H., et al. (2022) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2022.03.008 · Cited by 45
“Bone samples are generally defined with two mechanical properties, elastic modulus and hardness [44].”
BackgroundBiomechanical properties and clinical significance of cancellous bone in proximal femur: A review
Wang, H., Zhang, Y., Ren, C., Ding, K., Zhang, Q., Zhu, Y., & Chen, W. (2023) · Injury · doi:10.1016/j.injury.2023.03.010 · Cited by 43
Osteoporosis: interferon-gamma-mediated bone remodeling in osteoimmunology
Li, S., Liu, G., & Hu, S. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1396122 · Cited by 51
Use of Hydrogels in Regenerative Medicine: Focus on Mechanical Properties
Carton, F., Rizzi, M., Canciani, E., Sieve, G., Francesco, D. D., Casarella, S., Nunno, L. D., & Boccafoschi, F. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252111426 · Cited by 42
“Such mechanical behavior is also affected by cortical porosity, as this parameter negatively correlates with the tissue elasticity, by its compressive ultimate stress response, and by fracture toughness, finally accounting for the tissue-specific elastic modulus and yield stress [24,28–31].”
BackgroundLiu, J., Tang, Y., Yang, W., Tao, B., He, Y., Shen, X., Shen, T., Lin, C., & Cai, K. (2019) · Biomaterials Science · doi:10.1039/c8bm01611a · Cited by 41
Tan, X. H., Liu, L., Mitryashkin, A., Wang, Y., & Goh, J. C. H. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00313 · Cited by 36
Azadani, R. N., Karbasi, S., & Poursamar, S. A. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.129407 · Cited by 38
Biomechanics of immature human cortical bone: A systematic review
Szabo, E., & Rimnac, C. M. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104889 · Cited by 39
Joseph, B., Shah, H. H., & Perry, D. C. (2023) · Journal of Children s Orthopaedics · doi:10.1177/18632521231203009 · Cited by 35
Meng, D., Hou, Y., Kurniawan, D., Weng, R.-J., Chiang, W., & Wang, W. (2024) · ACS Applied Nano Materials · doi:10.1021/acsanm.3c05225 · Cited by 38
Harnessing the Potential of PLGA Nanoparticles for Enhanced Bone Regeneration
Hassan, M. O., Abdelnabi, H., & Mohsin, S. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16020273 · Cited by 41
“…bone tissues by adding different fractions of TiO 2 , in which increasing TiO 2 resulted in a higher Young’s modulus, indicating the potential to fine-tune Some literature indicates Young’s modulus ranging between 10–20 GPa and 23–26 GPa for human cancellous and cortical bones, respectively [62].”
BackgroundSingh, Y. P., & Dasgupta, S. (2022) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2022.2068943 · Cited by 38
“Characteristics features of human bones [2].”
Treatment of large bone defects in load-bearing bone: traditional and novel bone grafts
Yu, D., Shen, W., Dai, J., & Zhu, H. (2025) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b2300669 · Cited by 48
“Cancellous bone has a loose honeycomb (HC) struc‐ ture and a porosity of 40%‒95%, and accounts for ap‐ proximately 20% of total bone mass (Morgan et al., 2018).”
Gain, A. K., Cui, Y., & Zhang, L. (2024) · Materials Science and Engineering A · doi:10.1016/j.msea.2024.147220 · Cited by 40
Wang, Z., Nogueira, L. P., Haugen, H. J., van der Geest, I. C. M., Rodrigues, P. C. D. A., Janssen, D. W., Bitter, T., van den Beucken, J. J. J. P., & Leeuwenburgh, S. C. G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.12.023 · Cited by 42
“2 GPa, and 4–12 MPa and 50–800 MPa, respectively [55,56].”
BackgroundNaseem, R., Montalbano, G., German, M. J., Ferreira, A. M., Gentile, P., & Dalgarno, K. W. (2022) · Molecules · doi:10.3390/molecules27217633 · Cited by 30
“1 to 30 MPa), as the mechanical properties do not approach those of cortical bone (modulus ~18 GPa; strength ~70 MPa) [41].”
BackgroundInfluentialBiomechanical and clinical studies on lumbar spine fusion surgery: a review
Pradeep, K., & Pal, B. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02750-6 · Cited by 32
Silva-Barroso, A. S., Cabral, . S. D., Ferreira, P. C. N., Moreira, A. F., & Correia, I. J. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2023.124258 · Cited by 36
Molinero‐Mourelle, P., Cascos, R., Yılmaz, B., et al. (2021) · Materials · doi:10.3390/ma14092348 · Cited by 31
“For the reliability of measurement methods, some studies recommended a minimum of 50 measurements [33,34,52], and some proposed up to 100 measurements per specimen [22,26].”
MethodZhang, B., Nguyen, A. K., Narayan, R. J., & Huang, J. (2021) · Journal of the American Ceramic Society · doi:10.1111/jace.18048 · Cited by 35
“The pore size of cancellous bones varies between 50 and 850 μm; the porosity varies between 40 and 90% (59, 60).”
BackgroundLiu, J., Wu, X., Deng, X., Zhu, H., Wang, T., Wang, M., Yang, S., Xu, J., Chen, Q., Li, M., et al. (2022) · Cells · doi:10.3390/cells11244091 · Cited by 35
“Superior bone mechanical properties are the basis for bones to support movement and protect important organs [41].”
BackgroundSui, J., Pragnère, S., & Kurniawan, N. A. (2025) · Biomaterials Science · doi:10.1039/d5bm00210a · Cited by 39
Porta, M., Tonda‐Turo, C., Pierantozzi, D., Ciardelli, G., & Mancuso, E. (2020) · Polymers · doi:10.3390/polym12102233 · Cited by 33
“As result, the compressive modulus values have been found to vary in a range rather being ascribed to a single value [64].”
BackgroundVidal, E., Guillem‐Marti, J., Ginebra, M., Combes, C., Rupérez, E., & Rius, D. R. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.126557 · Cited by 31
Solid-state additive manufacturing of porous Ti-6Al-4V by supersonic impact
Moridi, A., Stewart, E. J., Wakai, A., Assadi, H., Gärtner, F., Guagliano, M., Klassen, T., & Dao, M. (2020) · Applied Materials Today · doi:10.1016/j.apmt.2020.100865 · Cited by 30
Architecture of bone tissue and its adaptation to pathological conditions
Bilgiç, E., Boyacıoğlu, Ö., Gizer, M., Korkusuz, P., & Korkusuz, F. (2020) · Comparative Kinesiology of the Human Body · doi:10.1016/b978-0-12-812162-7.00006-0 · Cited by 30
Pei, T., Su, G., Yang, J., Gao, W., Yang, X., Zhang, Y., Ren, J., Shen, Y., & Liu, X. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232415702 · Cited by 31
“As an example, the loss of mechanical stimulation leads to the disuse osteoporosis [3,4].”
Bioprinting of gelatin-based materials for orthopedic application
Waidi, Y. O., Kariim, I., & Datta, S. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1357460 · Cited by 35
Toward Fully Automated Personalized Orthopedic Treatments: Innovations and Interdisciplinary Gaps
Luo, Y. (2024) · Bioengineering · doi:10.3390/bioengineering11080817 · Cited by 39
“In the field of mechanical and biomechanical research, the mechanical properties of bones have been extensively investigated [194,195].”
BackgroundBeisekenov, N., Sadenova, M. A., Azamatov, B. N., & Syrnev, B. V. (2025) · Journal of Functional Biomaterials · doi:10.3390/jfb16050168 · Cited by 41
Biofabrication of 3D printed hydroxyapatite composite scaffolds for bone regeneration
Kim, Y., Lee, E. J., Davydov, A. V., Frukhtbeyen, S., Seppala, J. E., Takagi, S., Chow, L. C., & Alimperti, S. (2020) · Biomedical Materials · doi:10.1088/1748-605x/abcf03 · Cited by 33
Jin, Z., Liao, X., Da, W., Zhao, Y., Li, X., & Tang, D. (2021) · Stem Cell Research & Therapy · doi:10.1186/s13287-021-02228-6 · Cited by 34
Surface reconstruction and tissue recognition for robotic-based in situ bioprinting
Fortunato, G. M., Batoni, E., Bonatti, A. F., Vozzi, G., & Maria, C. D. (2022) · Bioprinting · doi:10.1016/j.bprint.2022.e00195 · Cited by 31
Mechanical Properties of 3D-Printed Porous Poly-ether-ether-ketone (PEEK) Orthopedic Scaffolds
Gummadi, S. K., Saini, A., Owusu-Danquah, J. S., & Sikder, P. (2022) · JOM · doi:10.1007/s11837-022-05361-6 · Cited by 33
Nelson, K., Kelly, C. N., & Gall, K. (2022) · Materials Science and Engineering B · doi:10.1016/j.mseb.2022.116013 · Cited by 29
Galotta, A., Rubenis, K., Ločs, J., & Sglavo, V. M. (2023) · Open Ceramics · doi:10.1016/j.oceram.2023.100418 · Cited by 40
Makurat‐Kasprolewicz, B., Ipakchi, H., Rajaee, P., Ossowska, A., Hejna, A., Farokhi, M., Mottaghitalab, F., Pawlak, M., Rabiee, N., Belka, M., et al. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.152703 · Cited by 29
Ingole, V. H., Ghule, S. S., Vuherer, T., Kokol, V., & Ghule, A. V. (2021) · Minerals · doi:10.3390/min11121390 · Cited by 33
“Thus, cancellous bone has a lower Young’s modulus and is more elastic than cortical bone [11,12].”
BackgroundA Review of Surgical Bone Drilling and Drill Bit Heat Generation for Implantation
Islam, M. A., Kamarrudin, N. S., Daud, R., Noor, S. N. F. M., Azmi, A. I., & Razlan, Z. M. (2022) · Metals · doi:10.3390/met12111900 · Cited by 45
“The challenge arises fr m the large range of qualities that differ from person to person depending on ge, gender, and dis ase [19,20].”
BackgroundRole of biomechanics in vascularization of tissue-engineered bones
Mokhtari‐Jafari, F., Amoabediny, G., & Dehghan, M. M. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109920 · Cited by 30
Baleani, M., Erani, P., Acciaioli, A., & Schileo, E. (2024) · Bioengineering · doi:10.3390/bioengineering11040395 · Cited by 37
“…bone toughening mechanisms [14] mostly related to the collagen phase (in fact bone tensile yield values are generally lower than compressive ones [3]); with respect to the common three-point bending testing because, in a heterogeneous material such as cortical bone, tensile testing maintains a…”
BackgroundNieuwoudt, M. K., Shahlori, R., Naot, D., Patel, R., Holtkamp, H. U., Aguergaray, C., Watson, M., Musson, D. S., Brown, C., Dalbeth, N., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-76337-2 · Cited by 27
He, L., Liu, X., & Rudd, C. D. (2021) · Polymers · doi:10.3390/polym13020270 · Cited by 28
“1–30 MPa and 10–3000 MPa, respectively [44,45].”
Khare, D., Singh, P., & Dubey, A. K. (2022) · Biomaterials Advances · doi:10.1016/j.bioadv.2022.213042 · Cited by 28
Kahar, N. N. F. N. M. N., Ahmad, N., Mariatti, M., Yahaya, B. H., Sulaiman, A. R., & Hamid, Z. A. A. (2022) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ac867f · Cited by 39
Ghafari, F., Karbasi, S., & Eslaminejad, M. B. (2023) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2023.127340 · Cited by 28
Biomimetic Nacre-Like Hydroxyapatite/Polymer Composites for Bone Implants
Tabrizian, P., Sun, H., Jargalsaikhan, U., Sui, T., Davis, S. A., & Su, B. (2023) · Journal of Functional Biomaterials · doi:10.3390/jfb14080393 · Cited by 29
“Therefore, there is a tremendous need to find bioactive and biocompatible materials with bone-like stiffness, strength, and toughness, that can prevent further postoperative complications, like limitation of range of motion, reduce pain, and minimize the need for additional surgery [1,6].”
BackgroundKim, M., Schöbel, L., Geske, M., Boccaccini, A. R., & Ghorbani, F. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.130666 · Cited by 28
Overview of porous magnesium-based scaffolds: development, properties and biomedical applications
Motaharinia, A., Drelich, J. W., Sharif, S., Ismail, A. F., Naeimi, F., Glover, A., Ebrahiminejad, M., & Bakhsheshi‐Rad, H. R. (2025) · Materials Futures · doi:10.1088/2752-5724/ad9493 · Cited by 33
Wang, J., Chen, J., Zhang, B., & Jia, X. (2021) · Acta Histochemica · doi:10.1016/j.acthis.2021.151718 · Cited by 27
Lu, T., Feng, S., He, F., et al. (2019) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36844 · Cited by 25
Șelaru, A., Herman, H., Vlăsceanu, G. M., Dinescu, S., Gharbia, S., Baltă, C., Roșu, M., Mihali, C. V., Ioniţă, M., Serafim, A., et al. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23010491 · Cited by 27
“despite being within the order of kPa while native bone sites reach 26 GPa [69], signifi-”
BackgroundResultInfluentialSchiavi, A., Fiume, E., Örlygsson, G., et al. (2022) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2022.06.022 · Cited by 25
Wang, L., Meng, Y., Feng, Y., Wang, H., Mao, L., Yu, S., & Wang, Z. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202201248 · Cited by 25
Färber, E., Orlov, A. V., Borisov, E. V., Repnin, A., Kuzin, S. A., Golubkov, N., & Popovich, A. (2022) · Metals · doi:10.3390/met12091476 · Cited by 26
Shendage, S. S., Ingole, V. H., Rasal, A. S., Chang, J., Birajdar, N. B., Pandey-Tiwari, A., Kashte, S., Vuherer, T., Schmitt, G., Cucchiarini, M., et al. (2024) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.3c06290 · Cited by 25
Rigidity‐Tunable Materials for Soft Engineering Systems
Roh, Y., Lim, D., Kang, M., Cho, J., Han, S., & Ko, S. H. (2024) · Advanced Engineering Materials · doi:10.1002/adem.202400563 · Cited by 25
Coburn, B., & Salary, R. R. (2025) · Bioengineering · doi:10.3390/bioengineering12040416 · Cited by 24
Yang, Z., Li, X., Zhang, B., Zhang, G., Huo, F., Zhou, C., Liang, X., Fan, Y., Tian, W., & Tan, Y. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.854693 · Cited by 33
Rizzo, M. G., Palermo, N., Alibrandi, P., Sciuto, E. L., Gaudio, C. D., Filardi, V., Fazio, B., Caccamo, A., Oddo, S., Calabrese, G., et al. (2023) · Biology · doi:10.3390/biology12030424 · Cited by 23
“Moreover, the value of the tensile strength of PLA scaffold is comparable with the physiological ultimate stress of cortical bone ranging from about 100–150 MPa [35,36].”
BackgroundInfluentialIn silico assessment of the bone regeneration potential of complex porous scaffolds
Asbai-Ghoudan, R., Nasello, G., Pérez, M. Á., Verbruggen, S. W., de Galarreta, S. R., & Rodríguez-Flórez, N. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.107381 · Cited by 24
Ceddia, M., Lamberti, L., & Trentadue, B. (2024) · Materials · doi:10.3390/ma17030673 · Cited by 28
“The listed values were extracted from [42–45].”
Ceddia, M., Solarino, G., Giannini, G., Giosa, G. D., Tucci, M., & Trentadue, B. (2024) · Journal of Composites Science · doi:10.3390/jcs8070254 · Cited by 29
Rossi, G. D., Vergani, L. M., & Buccino, F. (2024) · Materials · doi:10.3390/ma17215305 · Cited by 31
“For instance, studies report that scaffolds with porosities of 70–90% lead to superior bone ingrowth and osseointegration, supporting mechanical stability in vivo [27,28,164].”
BackgroundStem Cell-Seeded 3D-Printed Scaffolds Combined with Self-Assembling Peptides for Bone Defect Repair
Xu, H., Wang, C., Liu, C., Li, J., Peng, Z., Guo, J., & Zhu, L. (2021) · Tissue Engineering Part A · doi:10.1089/ten.tea.2021.0055 · Cited by 27
Effect of organic matrix alteration on strain rate dependent mechanical behaviour of cortical bone
Uniyal, P., Sihota, P., & Kumar, N. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104910 · Cited by 24
Understanding and utilizing textile-based electrostatic flocking for biomedical applications
McCarthy, A. D., Shah, R., John, J. V., Brown, D., & Xie, J. (2021) · Applied Physics Reviews · doi:10.1063/5.0070658 · Cited by 26
van Hoogstraten, S. W. G., Hermus, J. P. S., Loenen, A. C. Y., et al. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05428-0 · Cited by 23
“Peak contact pressures up to 177 MPa were found which are exceeding the ultimate yield point of trabecular bone, and thus presumably leads to bone damage [36].”
BackgroundGraded cellular structures for enhanced performance of additively manufactured orthopaedic implants
Thomas, J. P., Alsaleh, N. A., Ahmadein, M., Elfar, A. A., Farouk, H. A., & Essa, K. (2023) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-023-12843-7 · Cited by 29
“In addition and considering that the UCS and yield strength of the femur are 205 MPa and 115 MPa, respectively [44], the Gibson-Ashby model grading has increased both the UCS and yield strength to 530 MPa and 296 MPa, respectively, with a safety factor of more than 2.5 each, compared to the target…”
InfluentialNie, T., Venkatesh, V. S., Golub, S. B., Stok, K. S., Hemmatian, H., Desai, R., Handelsman, D. J., Zajac, J. D., Grossmann, M., & Davey, R. A. (2024) · Bone Research · doi:10.1038/s41413-023-00308-2 · Cited by 58
“36 Bending stress could be measured in future experiments to account for the increased cross-sectional area; however, this was not possible in the current study due to technical limitations.”
BackgroundYang, G., Mahadik, B. P., Choi, J. Y., Yu, J. R., Mollot, T., Jiang, B., He, X., & Fisher, J. P. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.11.040 · Cited by 25
“Severe trauma, aging-related disorders, and diseases can lead to critical-size bone defects[1, 2], which require surgical bone implantation to restore structural integrity and functionality.”
BackgroundIs it possible to 3D bioprint load-bearing bone implants? A critical review
Gupta, T., Ghosh, S. B., Bandyopadhyay‐Ghosh, S., & Sain, M. M. (2023) · Biofabrication · doi:10.1088/1758-5090/acf6e1 · Cited by 26
“Invertebrate bone is a highly optimized structure, exhibiting remarkably high specific fracture toughness and stiffness, despite the use of relatively brittle HA [241].”
BackgroundSabahi, N., Farajzadeh, E., Roohani, I., Wang, C. H., & Li, X. (2024) · Applied Materials Today · doi:10.1016/j.apmt.2024.102262 · Cited by 28
3D Printing of Polyester Scaffolds for Bone Tissue Engineering: Advancements and Challenges
Salehabadi, M., & Mirzadeh, H. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202401522 · Cited by 25
Kumar, P., Sharma, J., Kumar, R., Najser, J., Frantík, J., Manuja, A., Sunnam, N., & Praveenkumar, S. (2025) · Biomaterials Science · doi:10.1039/d4bm01606h · Cited by 28
Mechanical and morphological characterization of PMMA/bone composites in human femoral heads
Sas, A., Helgason, B., Ferguson, S. J., & van Lenthe, H. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104247 · Cited by 22
Zwirner, J., Safavi, S., Scholze, M., Li, K. C., Waddell, J. N., Busse, B., Ondruschka, B., & Hammer, N. (2021) · Scientific Reports · doi:10.1038/s41598-020-80548-y · Cited by 23
“Bstrength Touter | Tinner [MPa] 92 (52) 90 (53) 99 (64) 91 (58) 107 (73) 111 (38) 102 (130) 119 (149) 98 (40) 78 (54) 77 (43) 68 (58)”
Frank, M., Reisinger, A., Pahr, D. H., & Thurner, P. J. (2021) · JBMR Plus · doi:10.1002/jbm4.10503 · Cited by 29
“In the literature, no consensus has been reached so far on the influence of age and disease on trabecular tissue properties.((44)) On the one hand, no change of material properties of trabecular tissue of humans experiencing an osteoporotic fracture,((45,46)) of ovariectomized rats,((14,47)) and of postmenopausal wome…”
BackgroundPetta, D., D’Amora, U., D’Arrigo, D., Tomasini, M., Candrian, C., Ambrosio, L., & Moretti, M. (2022) · Biofabrication · doi:10.1088/1758-5090/ac8767 · Cited by 22
“Regarding the tensile strength, it ranges from 50 up to 150 MPa [41].”
InfluentialFabrication and Evaluation of Porous dECM/PCL Scaffolds for Bone Tissue Engineering
Wang, W., Zhou, X.-Q., Yin, Z., & Yu, X. (2023) · Journal of Functional Biomaterials · doi:10.3390/jfb14070343 · Cited by 22
“The modulus of trabecular bone ranges between 10 and 3000 MPa [47].”
BackgroundInfluentialDargusch, M. S., Soro, N., Demir, A. G., Venezuela, J., Sun, Q., Wang, Y., Abdal‐hay, A., Alali, A. Q., Ivanovski, S., Previtali, B., et al. (2023) · Smart Materials in Medicine · doi:10.1016/j.smaim.2023.10.003 · Cited by 22
“…the lattices exhibited yield strength at 0.2% strain ranging between 5 MPa and 77 MPa, which con fi rms that most of the Fe – 35Mn structures presented in this work are suf fi ciently strong for bone scaffold applications (see relevant mechanical properties of cortical bone in Table 4 [56]).”
BackgroundInfluentialDukle, A., & Sankar, M. R. (2024) · Materials Today Communications · doi:10.1016/j.mtcomm.2024.109776 · Cited by 32
Li, J. H., Wei, J., Li, A., Liu, H., Sun, J., & Qiao, H. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.657699 · Cited by 22
“In recent time, bone tissue engineering strategies for bioactive molecules incorporated into scaffolds have emerged and promote the stem cells’ ability to proliferate and differentiate, resulting in accelerated bone regeneration (Perez et al., 2018).”
BackgroundCurrent progress of self-healing polymers for medical applications in tissue engineering
Prado-Audelo, M. L. D., Caballero-Florán, I. H., Mendoza‐Muñoz, N., Giraldo‐Gómez, D. M., Sharifi‐Rad, J., Patra, J. K., González‐Torres, M., Florán, B., Cortés, H., & Leyva‐Gómez, G. (2021) · Iranian Polymer Journal · doi:10.1007/s13726-021-00943-8 · Cited by 24
Mica filled polyetherketoneketones for material extrusion 3D printing
Kennedy, Z. C., Christ, J. F., Fenn, M. D., Zhong, L., Chouyyok, W., Arnold, A. M., Denny, A. C., Albrecht, A., Silverstein, J. A., Erikson, R. L., et al. (2021) · Additive manufacturing · doi:10.1016/j.addma.2021.102492 · Cited by 25
Poly(2-ethyl-2-oxazoline) coating of additively manufactured biodegradable porous iron
Putra, N. E., Tigrine, A., Aksakal, S., de la Rosa, V. R., Taheri, P., Fratila-Apachitei, L. E., Mol, J. M. C., Zhou, J., & ZADPOOR, A. A. (2021) · Biomaterials Advances · doi:10.1016/j.msec.2021.112617 · Cited by 20
Dibazar, Z. E., Nie, L., Azizi, M., Nekounam, H., Hamidi, M., Shavandi, A., Izadi, Z., & Delattre, C. (2023) · Materials · doi:10.3390/ma16072799 · Cited by 23
“The mechanical properties of bone are essential for the ability of skeletons to support the movement and protect the vital organs of the body [40,41].”
BackgroundROSENBERG, J. L., Woolley, W., Elnunu, I. S., Kamml, J., Kammer, D. S., & Acevedo, C. (2023) · Biocell · doi:10.32604/biocell.2023.028014 · Cited by 28
“Even more significantly, toughness, energy dissipation, and ultimate strain are reduced by approximately 10%–15% every decade (Burstein et al., 1976; Nalla et al., 2004; Nyman et al., 2007; Koester et al., 2011; Zimmermann et al., 2011; Morgan et al., 2018).”
Background
Metadata
- Authors
- Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I.
- Affiliations
- Boston University (US)
- Corresponding author
- Morgan, Elise F.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2018-06-04
- Volume
- 20
- Issue
- 1
- Pages
- 119-143
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- PMC
- PMC6053074
- OpenAlex
- W2807165335
- Semantic Scholar
- a169125cebb03ba7d2bb7a6ffa25b4106fcdfc55
- Cited by
- 1,026
- References
- 174
- Citations by year
- 2026: 163 · 2025: 223 · 2024: 194 · 2023: 150 · 2022: 136 · 2021: 114 · 2020: 37 · 2019: 8 · 2018: 1
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- OpenBU (Boston University) (submittedVersion, cc-by)
- Funders
- National Science Foundation (1266243)
- National Institutes of Health (AR054620)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R56AR054620, R01AR054620)
- Division of Civil, Mechanical and Manufacturing Innovation
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- bone mechanical properties, bone mechanics, osteoporosis, diabetes mellitus, cortical bone, trabecular bone, elasticity, yield, fracture, fatigue (material), damages, bone mineral density, porosity, crosslinking, aging
- MeSH terms
- Aging, Bone and Bones, Bone Diseases, Diabetes Mellitus, Elasticity, Humans, Models, Theoretical, Osteoporosis, Quality of Life, Stress, Mechanical, Viscosity, Bone Density, Porosity, Anisotropy, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.