Bone Mechanical Properties in Healthy and Diseased States
Open accessThe DOI matches its Crossref record; 173 of the 174 references it cites were found in a registry or an index; 47 of the 225 sources its claims cite were checked for support.
Abstract
Review of bone mechanics across length scales, including cortical bone, trabecular bone, and whole bones, covering elasticity, yield, fracture, fatigue, and damage.
Overview
CoChat Summary
TL;DR
This review synthesizes current knowledge of bone mechanical behavior from the nanoscale to whole-bone scale in healthy, aging, and diseased states. It emphasizes porosity/bone quantity and bone-quality parameters such as cross-linking and protein composition as determinants of cortical, trabecular, and whole-bone stiffness, strength, toughness, fatigue, and damage.
Key findings
- Cortical bone has 5–15% porosity and trabecular bone 40–95%; cortical bone is anisotropic, strongest in longitudinal compression and weakest in transverse tension, with mode I fracture toughness \(K_{IC}\) of 2–6 MPa√m, lower for longitudinal than transverse fracture and lower at high strain rates.
- With aging, cortical tensile/compressive strength declines ~2% per decade from the third decade, tensile ultimate strain declines ~10% per decade from 5% at age 20–30 to <1% above age 80, and fracture toughness declines ~4% per decade; trabecular modulus and strength decline ~10% per decade, and proximal femoral strength declines ~10–12% per decade (~50% from early to late adulthood).
- Human trabecular bone apparent modulus ranges from 10 to 3,000 MPa and strength from 0.1 to 30 MPa; 70–90% of the variance in modulus and strength is explained by volume fraction or apparent density, with power-law exponents of ~2–3 for modulus and ~2 for compressive strength.
- Bone quality matters: nonenzymatic glycation cross-links are associated with increased brittleness, diabetes is associated with lower bone toughness and possibly heightened AGE accumulation, and long-term antiresorptive therapy is associated with decreased toughness.
Methods
- Narrative review of bone mechanics across length scales from hundreds of nanometers to tens of centimeters, covering cortical bone, trabecular bone, whole bones, and material behaviors including elasticity, yield, fracture, fatigue, and damage.
- No primary data collection or systematic search/meta-analysis is described; the review synthesizes in vitro, in vivo, imaging, analytical, and finite element modeling literature.
- It discusses bone quantity (density, porosity) and bone quality (cross-linking, protein composition) and identifies future research avenues.
Limitations
- Stated in the paper: no consensus exists on the most accurate multiaxial yield criterion for trabecular bone, largely because none has been validated with an independent set of specimens; few data are available on whether aging or disease affect trabecular tissue differently than cortical tissue; the mechanistic link between microdamage and increased fracture risk has not been established; and consensus has yet to emerge on Raman spectroscopy readouts as indicators of bone fragility.
- Evident from the text: as a narrative review, it does not report a systematic search strategy, inclusion criteria, or quantitative synthesis, and its conclusions draw on heterogeneous ex vivo, animal, and modeling studies.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
43 Valid · 4 Not valid · 117 Not checked · 68 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“In vitro mechanical tests have found that microdamage is associated with a decrease in modulus (9, 10)”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Not checked — no full text of the sourcecites [9] Burr DB Turner CH Naick P Forwood MR Ambrosius W 1998 Does microdamage accumulation affect the mechanical properties of bone? J Biomech 31 337 45 9672087 source
- Supportedcites [10] Nicolella DP Ni Q Chan KS 2011 Non-destructive characterization of microdamage in cortical bone using low field pulsed NMR J Mech Behav Biomed Mater 4 383 91 21316626 PMC3073569 source
The Introduction states that microdamage has been directly associated with modulus degradation. The Results compare measured and predicted elastic-modulus degradation in cyclically damaged cortical bone, and the Conclusions say the relationship agrees with experimental observations. Page numbers are not supplied in our copy. (LLM, conf=0.94)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“Preliminary values of fracture toughness at the microscale appear to be similar to those measured at the macroscale (41).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [41] Kataruka A Mendu K Okeoghene O Puthuvelil J Akono AT 2017 Microscopic assessment of bone toughness using scratch tests Bone Rep 6 17 25 28377977 PMC5365275 source
The Results & discussion section (“Fracture characteristics”) reports microscale scratch-test toughness values of 3.15 ± 0.56 and 3.49 ± 0.80 MPa√m. It explicitly says these fall within the 2.2–4.6 MPa√m range reported for macroscopic fracture tests. (LLM, conf=0.94)
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“and that this difference may be related to heightened accumulation of AGEs in diabetic bone (75).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [75] Rubin MR Paschalis EP Poundarik A Sroga GE McMahon DJ 2016 Advanced glycation endproducts and bone material properties in type 1 diabetic mice PLOS ONE 11 e0154700 27140650 PMC4854398 source
The Abstract reports increased skeletal AGEs and lower bone toughness in a type 1 diabetic mouse model, with higher AGEs correlating with lower macroscopic toughness. The Discussion likewise says AGE accumulation co-exists with bone deterioration, supporting the claim’s tentative wording. (LLM, conf=0.91)
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“and there is concern that long-term use of antiresorptive therapies can result in decreased toughness (48, 72, 73).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Supportedcites [48] Lloyd AA Gludovatz B Riedel C Luengo EA Saiyed R 2017 Atypical fracture with long-term bisphosphonate therapy is associated with altered cortical composition and reduced fracture resistance PNAS 114 8722 27 28760963 PMC5565436 source
The Conclusion states that long-term antiresorptive treatment can affect bone toughness through reductions in intrinsic and extrinsic toughening mechanisms. The Loss of Intrinsic Toughening section reports reduced fracture toughness in cortical bone from bisphosphonate-treated patients, supporting the citing sentence’s hedged concern. (LLM, conf=0.92)
- Supportedcites [72] Allen MR Burr DB 2011 Bisphosphonate effects on bone turnover, microdamage, and mechanical properties: what we think we know and what we know that we don’t know Bone 49 56 65 20955825 source
The mechanical-properties discussion (page not provided) says bisphosphonate treatment consistently reduces bone toughness and that toughness declines with longer treatment. The paper discusses this as a concern, while noting that whether the change occurs in human bone remains to be determined. (LLM, conf=0.90)
- Not checked — no full text of the sourcecites [73] Chapurlat RD Delmas PD 2009 Bone microdamage: a clinical perspective Osteoporos Int 20 1299 308 19291343 source
plainstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“The mechanical effects of osteoporosis therapies, however, differ among the types of therapy (70, 71)”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
What the sources say
- Not checked — no full text of the sourcecites [70] Campbell GM Tiwari S Picke AK Hofbauer C Rauner M 2016 Effects of insulin therapy on porosity, non-enzymatic glycation and mechanical competence in the bone of rats with type 2 diabetes mellitus Bone 91 186 93 27497735 source
- Supportedcites [71] Brock GR Chen JT Ingraffea AR MacLeay J Pluhar GE 2015 The effect of osteoporosis treatments on fatigue properties of cortical bone tissue Bone Rep 2 8 13 25642445 PMC4306187 source
The Discussion and conclusions state that differences in cortical bone fatigue life depended on treatment class and drug: alendronate reduced fatigue life, PTH increased it, and raloxifene and zoledronate did not change it. This supports the cited claim that mechanical effects differ among osteoporosis therapies. (LLM, conf=0.93)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
165 more claims · 23 with their cited sources checked
Create a free account to see all 232 claims and to verify the 14 references still open.
- Probably not a substantial claim. 25
- It may state two separate claims as one. 41
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
“When loaded in tension along the longitudinal direction, cortical bone exhibits a bilinear stress–strain response in which a distinct yield point separates a linearly elastic region and a region of linear hardening that ends abruptly at a fracture strain of less than 3% (Figure 1a).”
§ Bone Mechanical Properties in Healthy and Diseased States > 2. MECHANICAL PROPERTIES OF BONE TISSUE > 2.1. Cortical Bone
“Tensile ultimate strain decreases by approximately 10% per decade, from a high of 5% strain at age 20–30 years to a low of less than 1% strain above age 80 years.”
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303 · cited 1×
“Measures of trabecular architecture include trabecular thickness, trabecular spacing, trabecular number, connectivity density, structure model index (SMI; a measure of how rod-like versus plate-like the architecture is), and the degree of anisotropy (83).”
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283 · cited 1×
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209 · cited 3×
“Numerous studies have indicated that the power-law exponent for human trabecular bone is between two and three for modulus (91) and two for compressive strength (Figure 4) (82).”
Self-citationComparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142 · cited 1×
“Results from this approach place the elastic modulus of human trabecular tissue at approximately 10% less, tensile yield strain at 15% less, and tensile/compressive tissue strength at 25% less than that of cortical bone (142).”
Self-citationBiomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961 · cited 1×
“Using this approach, investigators attributed the experimentally observed dependence of Young’s modulus and compressive strength on apparent density raised to the second power to bendingdominated linear elastic behavior and failure by buckling (127).”
Riggs, B. L., Melton, L. J., Robb, R. A., Camp, J. J., Atkinson, E. J., Peterson, J. M., Rouleau, P. A., McCollough, C. H., Bouxsein, M. L., & Khosla, S. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040916 · Cited by 925 · cited 2×
“For the vertebrae, an increase in the cross-sectional area with aging has been reported for both men and women (154), and one study found that this increase was three times greater in men than in women (158).”
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924 · cited 1×
“Elastic moduli measured by nanoindentation are on the order of 23 GPa and 26 GPa for osteonal and interstitial lamellae, respectively, in the longitudinal direction (36, 37), and are approximately 45% lower in the transverse direction (37).”
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Mineralized Collagen Fibrils: A Mechanical Model with a Staggered Arrangement of Mineral Particles
Jäger, I., & Fratzl, P. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76426-5 · Cited by 793
Age-related changes in the collagen network and toughness of bone
Wang, X., Shen, X., Li, X., & Mauli Agrawal, C. (2002) · Bone · doi:10.1016/s8756-3282(01)00697-4 · Cited by 777 · cited 4×
“Techniques such as Raman spectroscopy and Fourier transform IR spectroscopy can provide high-resolution spatial mapping of parameters indicative of the ratio of carbonate to phosphate and the relative amounts of mineral, proteoglycan, lipid, water, and nonenzymatic cross-links [also known as advanced glycation end pro…”
InfluentialBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709 · cited 1×
“Approximately 70–90% of the variances in the modulus and strength of trabecular bone can be explained by volume fraction or apparent density (90, 91).”
McCalden, R. W., McGeough, J. A., Barker, M. B., & Court-Brown, C. M. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199308000-00009 · Cited by 709 · cited 3×
“those of most other biological materials are due to bone’s mineral content, the normal physiological range of mineralization is not large enough to cause substantial variations in these mechanical properties (45).”
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705 · cited 6×
“Yield strains in trabecular bone exhibit only a weak dependence on apparent density and volume fraction (82).”
InfluentialSelf-citationStiffness of compact bone: Effects of porosity and density
Schaffler, M. B., & Burr, D. B. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90186-8 · Cited by 652 · cited 1×
“Cortical porosity is negatively correlated with Young’s modulus (42), compressive ultimate stress (43), and fracture toughness (44).”
Aging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
Harrigan, T. P., & Mann, R. W. (1984) · Journal of Materials Science · doi:10.1007/bf00540446 · Cited by 603 · cited 1×
“The data on directional density for a given specimen or region can be represented graphically by an ellipsoid, for which the ratio of the major and minor axes is the degree of anisotropy, and analytically by the fabric tensor, a positive definite, second-order tensor whose eigenvalues are the lengths of the major, min…”
The quantitative morphology of anisotropic trabecular bone
Whitehouse, W. J. (1974) · Journal of Microscopy · doi:10.1111/j.1365-2818.1974.tb03878.x · Cited by 579 · cited 2×
“MIL, as well as other methods, quantifies the directional density (the amount of tissue in a given direction) of the tissue.”
The relationship between the elasticity tensor and the fabric tensor
Cowin, S. C. (1985) · Mechanics of Materials · doi:10.1016/0167-6636(85)90012-2 · Cited by 570
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547 · cited 1×
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
Influence of nonenzymatic glycation on biomechanical properties of cortical bone
Vashishth, D., Gibson, G. J., Khoury, J. I., Schaffler, M. B., Kimura, J., & Fyhrie, D. P. (2001) · Bone · doi:10.1016/s8756-3282(00)00434-8 · Cited by 525 · cited 1×
“Cross-links formed specifically via nonenzymatic glycation have been associated with increased brittleness of the tissue (49).”
Dynamic response of bone and muscle tissue.
McElhaney, J. H. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.4.1231 · Cited by 509 · cited 1×
“Viscoelasticity—The effect of loading rate on strength and modulus is only moderate, as a six-order increase in the strain rate raises the modulus only by a factor of two and the strength by a factor of three (1).”
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492 · cited 3×
“Both modulus and strength decrease with age, falling by approximately 10% per decade (92, 147).”
Cyclic mechanical property degradation during fatigue loading of cortical bone
Pattin, C. A., Caler, W. E., & Carter, D. R. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00156-1 · Cited by 442 · cited 1×
“Fatigue loading results in progressive degradation of mechanical properties such as fracture toughness, modulus, and strength (20, 21).”
Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431 · cited 1×
“In these studies, the tissue modulus is determined from a ratio to apparent modulus calibrated against experimental results (141).”
Bone composition: relationship to bone fragility and antiosteoporotic drug effects
Boskey, A. L. (2013) · BoneKEy Reports · doi:10.1038/bonekey.2013.181 · Cited by 424 · cited 1×
“Techniques such as Raman spectroscopy and Fourier transform IR spectroscopy can provide high-resolution spatial mapping of parameters indicative of the ratio of carbonate to phosphate and the relative amounts of mineral, proteoglycan, lipid, water, and nonenzymatic cross-links [also known as advanced glycation end pro…”
Does microdamage accumulation affect the mechanical properties of bone?
Burr, D. B., Turner, C. H., Naick, P., Forwood, M. R., Ambrosius, W., Sayeed Hasan, M., & Pidaparti, R. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00016-5 · Cited by 417 · cited 1×
“In vitro mechanical tests have found that microdamage is associated with a decrease in modulus (9, 10), and a weak inverse relationship between fracture toughness and microdamage density has been reported (11).”
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401 · cited 2×
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.”
(1960) · Henry Ford Hospital medical bulletin · Cited by 397
Silva, M. J., & Gibson, L. J. (1997) · International Journal of Mechanical Sciences · doi:10.1016/s0020-7403(96)00065-3 · Cited by 364
Contributions of Raman spectroscopy to the understanding of bone strength
Mandair, G. S., & Morris, M. D. (2015) · BoneKEy Reports · doi:10.1038/bonekey.2014.115 · Cited by 358 · cited 1×
“Techniques such as Raman spectroscopy and Fourier transform IR spectroscopy can provide high-resolution spatial mapping of parameters indicative of the ratio of carbonate to phosphate and the relative amounts of mineral, proteoglycan, lipid, water, and nonenzymatic cross-links [also known as advanced glycation end pro…”
Mechanical and morphological effects of strain rate on fatigue of compact bone
Schaffler, M. B., Radin, E. L., & Burr, D. B. (1989) · Bone · doi:10.1016/8756-3282(89)90055-0 · Cited by 338 · cited 1×
“Microcrack accumulation increases exponentially with age in cortical bone and is significantly higher in the bones of women versus men (12, 13).”
Fabric and elastic principal directions of cancellous bone are closely related
Odgaard, A., Kabel, J., van Rietbergen, B., Dalstra, M., & Huiskes, R. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00177-7 · Cited by 338 · cited 2×
“Trabecular bone often exhibits orthotropic symmetry (94, 95), although in some cases, such as in the vertebrae, transverse isotropy has been reported (93).”
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330 · cited 1×
“Basic material properties—As with cortical bone, the strength of trabecular bone is greater in compression than tension, and is lowest in shear, although these differences decrease with decreasing apparent density (78).”
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
Subperiosteal Expansion and Cortical Remodeling of the Human Femur and Tibia with Aging
Ruff, C. B., & Hayes, W. C. (1982) · Science · doi:10.1126/science.7112107 · Cited by 318 · cited 1×
“The net result is a thinner cortex and smaller cross-sectional area (despite the increase in periosteal diameter), but not necessarily any decrease in the moments of inertia (Figure 6) (153).”
The effects of ageing and changes in mineral content in degrading the toughness of human femora
Currey, J. D., Brear, K., & Zioupos, P. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00048-8 · Cited by 318 · cited 1×
“Effects of aging and disease on the mechanical properties of cortical bone—Age-related changes in the mechanical properties of cortical bone have been attributed to increased porosity (45), hypermineralization (64), microdamage accumulation (23), increased concentration of AGEs (65), and decreased quantity of noncolla…”
Mosekilde, L. (1989) · Bone · doi:10.1016/8756-3282(89)90074-4 · Cited by 316
Age-related reductions in the strength of the femur tested in a fall-loading configuration.
Courtney, A. C., Wachtel, E. F., Myers, E. R., & Hayes, W. C. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199503000-00008 · Cited by 301
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292 · cited 1×
“Young’s modulus can vary by as much as 100-fold, and strength as much as fivefold, within a single epiphysis (88).”
Kaptoge, S., Beck, T. J., Reeve, J., Stone, K. L., Hillier, T. A., Cauley, J. A., & Cummings, S. R. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080802 · Cited by 283 · cited 1×
“For the proximal femur, neck-shaft angle and bone diameter are larger in individuals with fracture compared with those of control subjects (161).”
Compact bone fatigue damage—I. Residual strength and stiffness
Carter, D. R., & Hayes, W. C. (1977) · Journal of Biomechanics · doi:10.1016/0021-9290(77)90005-7 · Cited by 268 · cited 1×
“Cortical bone has greater resistance to fatigue failure in compression than in tension (22) and at higher loading frequencies (23, 24).”
Dilatational band formation in bone
Poundarik, A. A., Diab, T., Sroga, G. E., Ural, A., Boskey, A. L., Gundberg, C. M., & Vashishth, D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201513109 · Cited by 265
Anisotropy of Young's modulus of bone
Katz, J. L. (1980) · Nature · doi:10.1038/283106a0 · Cited by 264
Bone creep-fatigue damage accumulation
Caler, W. E., & Carter, D. R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90013-4 · Cited by 263 · cited 1×
“Cortical bone has greater resistance to fatigue failure in compression than in tension (22) and at higher loading frequencies (23, 24).”
Fracture in human cortical bone: local fracture criteria and toughening mechanisms
Nalla, R. K., Stölken, J. S., Kinney, J. H., & Ritchie, R. O. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.010 · Cited by 260 · cited 4×
“The preferential alignment of osteons in cortical bone provides effective, extrinsic toughening that is anisotropic—a crack propagating perpendicular to the osteons (transversely oriented crack) is more likely to deflect and twist than is a crack propagating parallel to the osteon (longitudinally oriented crack)—and t…”
InfluentialA comparison of the fatigue behavior of human trabecular and cortical bone tissue
Choi, K., & Goldstein, S. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90051-2 · Cited by 247 · cited 1×
“This ranking is consistent with the results of a comparison of measured fatigue strengths in trabecular versus cortical tissue (143).”
Effect of aging on the toughness of human cortical bone: evaluation by R-curves
Nalla, R. K., Kruzic, J. J., Kinney, J. H., & Ritchie, R. O. (2004) · Bone · doi:10.1016/j.bone.2004.07.016 · Cited by 244
The nanocomposite nature of bone drives its strength and damage resistance
Tertuliano, O. A., & Greer, J. R. (2016) · Nature Materials · doi:10.1038/nmat4719 · Cited by 227 · cited 1×
“However, compression tests on micropillars indicate that both the strength and ductility of cortical tissue are higher at the microscale versus the macroscale (39, 40).”
An Application of Nanoindentation Technique to Measure Bone Tissue Lamellae Properties
Hoffler, C. E., Guo, X. E., Zysset, P. K., & Goldstein, S. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2073671 · Cited by 222 · cited 1×
“Although the nanoscale moduli appear higher than those at greater length scales (Table 1), this difference may be due to the fact that most nanoindentation measurements on bone are conducted under dry conditions (38).”
McCALDEN, R. W., McGEOUGH, J. A., & COURT-BROWN, C. M. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199703000-00016 · Cited by 221 · cited 1×
“Both modulus and strength decrease with age, falling by approximately 10% per decade (92, 147).”
Trabecular bone microdamage and microstructural stresses under uniaxial compression
Nagaraja, S., Couse, T. L., & Guldberg, R. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.013 · Cited by 220 · cited 1×
“These distributions have been correlated with microdamage accumulation (105), bone formation/resorption (135), and bone failure (112).”
Allen, M. R., & Burr, D. B. (2011) · Bone · doi:10.1016/j.bone.2010.10.159 · Cited by 219 · cited 1×
“The mechanical effects of osteoporosis therapies, however, differ among the types of therapy (70, 71), and there is concern that long-term use of antiresorptive therapies can result in decreased toughness (48, 72, 73).”
Nilsson, A. G., Sundh, D., Johansson, L., Nilsson, M., Mellström, D., Rudäng, R., Zoulakis, M., Wallander, M., Darelid, A., & Lorentzon, M. (2017) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3057 · Cited by 217 · cited 1×
“However, an association between cortical porosity and diabetes may depend on anatomic site (166), and not all measures of bone microstructure are deficient in diabetics versus controls (167).”
Failure mechanisms in human vertebral cancellous bone
Fyhrie, D. P., & Schaffler, M. B. (1994) · Bone · doi:10.1016/8756-3282(94)90900-8 · Cited by 215 · cited 1×
“The large reduction in apparent modulus that occurs with overloading (Figure 2b) results from damage within the trabeculae, namely microscopic cracking as opposed to overt fracture of individual trabeculae (104).”
Hunter, D. J., Gerstenfeld, L., Bishop, G., Davis, A. D., Mason, Z. D., Einhorn, T. A., Maciewicz, R. A., Newham, P., Foster, M., Jackson, S., et al. (2009) · Arthritis Research & Therapy · doi:10.1186/ar2601 · Cited by 214 · cited 1×
“Pronounced changes in trabecular architecture have also been observed in osteoarthritis (148), and evidence suggests that the relatively sclerotic appearance of the osteoarthritic trabecular structure may coexist with lower mineral density and stiffness of the tissue (149).”
Self-citationAn alternative model for anisotropic elasticity based on fabric tensors
Zysset, P. K., & Curnier, A. (1995) · Mechanics of Materials · doi:10.1016/0167-6636(95)00018-6 · Cited by 210 · cited 1×
“These relations were further developed to uncouple volume fraction from fabric (128) and to ensure positive definiteness of the elasticity tensor a priori (129).”
Hellmich, C., Barthélémy, J.-F., & Dormieux, L. (2004) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2004.05.004 · Cited by 210
Liu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., & Guo, X. E. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060716 · Cited by 207 · cited 1×
“Combination of the micro-FE approach with digital topological analysis (134), a method of classifying the individual trabeculae within a specimen as rods or plates and of quantifying the orientation of each trabecula, has enabled study of the way in which trabecular architecture, and changes in architecture, transmits…”
Kabel, J., van Rietbergen, B., Odgaard, A., & Huiskes, R. (1999) · Bone · doi:10.1016/s8756-3282(99)00190-8 · Cited by 206
Duan, Y., Turner, C. H., Kim, B.-T., & Seeman, E. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.12.2267 · Cited by 204 · cited 2×
“For the vertebrae, an increase in the cross-sectional area with aging has been reported for both men and women (154), and one study found that this increase was three times greater in men than in women (158).”
Effects of Bone Matrix Proteins on Fracture and Fragility in Osteoporosis
Sroga, G. E., & Vashishth, D. (2012) · Current Osteoporosis Reports · doi:10.1007/s11914-012-0103-6 · Cited by 191 · cited 1×
“Effects of aging and disease on the mechanical properties of cortical bone—Age-related changes in the mechanical properties of cortical bone have been attributed to increased porosity (45), hypermineralization (64), microdamage accumulation (23), increased concentration of AGEs (65), and decreased quantity of noncolla…”
Contribution, development and morphology of microcracking in cortical bone during crack propagation
Vashishth, D., Tanner, K. E., & Bonfield, W. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00010-5 · Cited by 189 · cited 1×
“Moreover, in vitro studies have noted that microdamage can increase resistance to crack growth (14), particularly if the damage is in the form of linear microcracks ahead of a larger crack (15).”
Age‐related variations in the microstructure of human tibial cancellous bone
Ding, M., Odgaard, A., Linde, F., & Hvid, I. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00132-2 · Cited by 186 · cited 1×
“For certain anatomic sites, such as the vertebral body and proximal tibia, an increase in the anisotropy of the trabecular structure is observed (Figure 5) (145, 146).”
Schwiedrzik, J., Raghavan, R., Bürki, A., LeNader, V., Wolfram, U., Michler, J., & Zysset, P. (2014) · Nature Materials · doi:10.1038/nmat3959 · Cited by 182 · cited 1×
“However, compression tests on micropillars indicate that both the strength and ductility of cortical tissue are higher at the microscale versus the macroscale (39, 40).”
Ding, M., Odgaard, A., Hvid, I., & Hvid, I. (2003) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.85b6.12595 · Cited by 177 · cited 1×
“Pronounced changes in trabecular architecture have also been observed in osteoarthritis (148), and evidence suggests that the relatively sclerotic appearance of the osteoarthritic trabecular structure may coexist with lower mineral density and stiffness of the tissue (149).”
Age-dependence of femoral strength in white women and men
Keaveny, T. M., Kopperdahl, D. L., Melton, L. J., Hoffmann, P. F., Amin, S., Riggs, B. L., & Khosla, S. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091033 · Cited by 171
Variations in strength and structure of cancellous bone at the knee
Behrens, J. C., Walker, P. S., & Shoji, H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90010-4 · Cited by 171 · cited 1×
“Cortical porosity is negatively correlated with Young’s modulus (42), compressive ultimate stress (43), and fracture toughness (44).”
Mechanical properties of trabecular bone. Dependency on strain rate
Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90305-7 · Cited by 171
Bone geometry and skeletal fragility
Bouxsein, M. L., & Karasik, D. (2006) · Current Osteoporosis Reports · doi:10.1007/s11914-006-0002-9 · Cited by 165
Anisotropic yield behavior of bone under combined axial force and torque
Cezayirlioglu, H., Bahniuk, E., Davy, D. T., & Heiple, K. G. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90045-4 · Cited by 164
The fracture mechanics of human bone: influence of disease and treatment
Zimmermann, E. A., Busse, B., & Ritchie, R. O. (2015) · BoneKEy Reports · doi:10.1038/bonekey.2015.112 · Cited by 164 · cited 2×
“The direction dependency of the contribution of these toughening mechanisms may also explain the anisotropy in the increase in fracture toughness with crack growth (a phenomenon known as a rising R curve) (19).”
Zimmermann, E. A., Gludovatz, B., Schaible, E., Busse, B., & Ritchie, R. O. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.066 · Cited by 163 · cited 1×
“Values of KIC, the fracture toughness for so-called mode I loading (tensile loading), range between 2 and 6 MPa√m and tend to be lower for longitudinal than for transverse fracture (15, 16) and to be lower at high strain rates (17, 18).”
Lloyd, A. A., Gludovatz, B., Riedel, C., Luengo, E. A., Saiyed, R., Marty, E., Lorich, D. G., Lane, J. M., Ritchie, R. O., Busse, B., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1704460114 · Cited by 158 · cited 2×
“However, increased mineral content, such as that which can occur with long-term bisphosphonate therapy for treatment of osteoporosis, is associated with decreased fracture toughness (48).”
Zioupos, P., Hansen, U., & Currey, J. D. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.07.025 · Cited by 156 · cited 1×
“Cortical bone is more brittle at high strain rates, and loading rate also has an effect on the accumulation of damage within bone tissue (2).”
Mechanical behavior of human trabecular bone after overloading
Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170308 · Cited by 155 · cited 1×
“If a specimen is compressed beyond yield (not exceeding 5% strain), unloaded, and reloaded, permanent residual strains and a loss of stiffness (as quantified by a comparison of the slope of the unloading curve to the initial elastic modulus) and strength occur (Figure 1d) (80).”
How Tough Is Brittle Bone? Investigating Osteogenesis Imperfecta in Mouse Bone
Carriero, A., Zimmermann, E. A., Paluszny, A., Tang, S. Y., Bale, H., Busse, B., Alliston, T., Kazakia, G., Ritchie, R. O., & Shefelbine, S. J. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2172 · Cited by 149 · cited 1×
“For example, studies of osteogenesis imperfecta, a group of rare genetic disorders that affect type I collagen and are characterized by low bone toughness, indicate that fewer enzymatic cross-links, more nonenzymatic cross-links, increased porosity, and reduced fraction of lamellar bone may all work to increase tissue…”
Fatigue Microdamage as an Essential Element of Bone Mechanics and Biology
Martin, R. B. (2003) · Calcified Tissue International · doi:10.1007/s00223-002-1059-9 · Cited by 148 · cited 1×
“The presence of microdamage in bone was first reported by Frost (4) and is now recognized to be a normal consequence of physiologic loading (5).”
The Anisotropic Hooke's Law for Cancellous Bone and Wood
Yang, G., Kabel, J., Van Rietbergen, B., Odgaard, A., Huiskes, R., & Cown, S. C. (1998) · Journal of Elasticity · doi:10.1023/a:1007575322693 · Cited by 140 · cited 1×
“Trabecular bone often exhibits orthotropic symmetry (94, 95), although in some cases, such as in the vertebrae, transverse isotropy has been reported (93).”
A three-dimensional elastic plastic damage constitutive law for bone tissue
Garcia, D., Zysset, P. K., Charlebois, M., & Curnier, A. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-008-0125-2 · Cited by 137 · cited 1×
“Further research is also needed to build on recent advances in studying the multiaxial mechanical behavior of trabecular bone following yield (124, 125).”
Christiansen, B. A., Kopperdahl, D. L., Kiel, D. P., Keaveny, T. M., & Bouxsein, M. L. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.287 · Cited by 135 · cited 1×
“At the same time, age-related bone loss occurs nonuniformly throughout the vertebrae in a manner that differs between men and women (159); as such, the effect of the age-related increase in cross-sectional area is difficult to isolate.”
Pidaparti, R. M. V., Chandran, A., Takano, Y., & Turner, C. H. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00147-6 · Cited by 133
Age-related differences in post-yield damage in human cortical bone. Experiment and model
Courtney, A. C., Hayes, W. C., & Gibson, L. J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)84542-8 · Cited by 131
Banse, X., Devogelaer, J. P., Munting, E., Delloye, C., Cornu, O., & Grynpas, M. (2001) · Bone · doi:10.1016/s8756-3282(01)00425-2 · Cited by 130 · cited 1×
“For example, in the vertebrae, variations in density and architecture have been observed along the superior–inferior and posterior– anterior directions (87).”
Roux, J.-P., Wegrzyn, J., Arlot, M. E., Guyen, O., Delmas, P. D., Chapurlat, R., & Bouxsein, M. L. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090803 · Cited by 129
Yield Behavior of Bovine Cancellous Bone
Turner, C. H. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168375 · Cited by 127 · cited 1×
“5% (97, 99), whereas yield strains range from 0.”
Biomechanical consequences of an isolated overload on the human vertebral body
Kopperdahl, D. L., Pearlman, J. L., & Keaveny, T. M. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180502 · Cited by 120 · cited 1×
“These effects occur in trabecular samples and in the entire vertebral body (81), indicating that isolated overloads that do not cause overt fracture of the bone may cause subtle but cumulative permanent deformations that could lead to clinical fractures.”
Matsuura, M., Eckstein, F., Lochmüller, E.-M., & Zysset, P. K. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0073-7 · Cited by 117 · cited 1×
“More recent research has indicated that the fabric–mechanical property relationships may depend on anatomic site (130).”
A 3D damage model for trabecular bone based on fabric tensors
Zysset, P. K., & Curnier, A. (1996) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)80006-6 · Cited by 117 · cited 1×
“Multiaxial loading can lead to more severe reductions in stiffness (27) and fatigue life (28) as compared to uniaxial loading.”
Compressive fatigue behavior of human vertebral trabecular bone
Rapillard, L., Charlebois, M., & Zysset, P. K. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.033 · Cited by 113 · cited 1×
“The number of cycles to failure in human vertebral trabecular bone is well predicted by a power-law relationship in which the independent variables are volume fraction, fabric, and applied stress, and a significant contribution of the degree of anisotropy toward the prediction of fatigue life has been observed (117).”
Nyman, J. S., Even, J. L., Jo, C.-H., Herbert, E. G., Murry, M. R., Cockrell, G. E., Wahl, E. C., Bunn, R. C., Lumpkin, C. K., Fowlkes, J. L., et al. (2011) · Bone · doi:10.1016/j.bone.2010.12.016 · Cited by 112 · cited 2×
“evidence also indicates that diabetes is associated with lower bone toughness as compared with normal cortical bone (70, 74) and that this difference may be related to heightened accumulation of AGEs in diabetic bone (75).”
Sansalone, V., Naili, S., Bousson, V., Bergot, C., Peyrin, F., Zarka, J., Laredo, J. D., & Haïat, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.034 · Cited by 109
Nonlinear Behavior of Trabecular Bone at Small Strains
Morgan, E. F., Yeh, O. C., Chang, W. C., & Keaveny, T. M. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1338122 · Cited by 107 · cited 1×
“Nevertheless, this tissue is frequently treated as a linear elastic material, and once the modulus is calculated from a linear or polynomial curve fit (79) to the initial portion of the curve, the yield point is defined by the 0.”
Self-citationA Global Relationship Between Trabecular Bone Morphology and Homogenized Elastic Properties
Zysset, P. K., Goulet, R. W., & Hollister, S. J. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834756 · Cited by 105 · cited 1×
“Trabecular bone often exhibits orthotropic symmetry (94, 95), although in some cases, such as in the vertebrae, transverse isotropy has been reported (93).”
Influence of microdamage on fracture toughness of the human femur and tibia
Norman, T. L., Yeni, Y. N., Brown, C. U., & Wang, Z. (1998) · Bone · doi:10.1016/s8756-3282(98)00103-3 · Cited by 102 · cited 1×
“In vitro mechanical tests have found that microdamage is associated with a decrease in modulus (9, 10), and a weak inverse relationship between fracture toughness and microdamage density has been reported (11).”
Sequential labelling of microdamage in bone using chelating agents
Lee, T. C., Arthur, T. L., Gibson, L. J., & Hayes, W. C. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180222 · Cited by 101 · cited 1×
“(25, 26) have enabled more in-depth study of the relationships among microcracking, microstructure, and macroscale mechanical properties.”
Fracture toughness of compact bone
Bonfield, W., & Datta, P. K. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90151-2 · Cited by 94 · cited 1×
“Values of KIC, the fracture toughness for so-called mode I loading (tensile loading), range between 2 and 6 MPa√m and tend to be lower for longitudinal than for transverse fracture (15, 16) and to be lower at high strain rates (17, 18).”
The torsional properties of single selected osteons
Ascenzi, A., Baschieri, P., & Benvenuti, A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90260-7 · Cited by 91
Hong, J., Cabe, G. D., Tedrow, J. R., Hipp, J. A., & Snyder, B. D. (2004) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2003.09.006 · Cited by 91 · cited 1×
“spatial variations in tissue mineral density and then use density–modulus relationships to avoid the assumption of a homogeneous modulus distribution (150).”
Effect of aging on the transverse toughness of human cortical bone: Evaluation by R-curves
Koester, K. J., Barth, H. D., & Ritchie, R. O. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2011.05.020 · Cited by 90
Advanced Glycation Endproducts and Bone Material Properties in Type 1 Diabetic Mice
Rubin, M. R., Paschalis, E. P., Poundarik, A., Sroga, G. E., McMahon, D. J., Gamsjaeger, S., Klaushofer, K., & Vashishth, D. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154700 · Cited by 90 · cited 1×
“evidence also indicates that diabetes is associated with lower bone toughness as compared with normal cortical bone (70, 74) and that this difference may be related to heightened accumulation of AGEs in diabetic bone (75).”
Elastic Anisotropy of Human Cortical Bone Secondary Osteons Measured by Nanoindentation
Franzoso, G., & Zysset, P. K. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3005162 · Cited by 89 · cited 1×
“Elastic moduli measured by nanoindentation are on the order of 23 GPa and 26 GPa for osteonal and interstitial lamellae, respectively, in the longitudinal direction (36, 37), and are approximately 45% lower in the transverse direction (37).”
Microarchitecture Influences Microdamage Accumulation in Human Vertebral Trabecular Bone
Arlot, M. E., Burt-Pichat, B., Roux, J.-P., Vashishth, D., Bouxsein, M. L., & Delmas, P. D. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080517 · Cited by 89 · cited 1×
“For example, more microdamage is found in regions with low volume fraction and high SMI—indicating a predominance of trabecular rods (110, 111).”
Nair, A. K., Gautieri, A., & Buehler, M. J. (2014) · Biomacromolecules · doi:10.1021/bm5003416 · Cited by 89
Compressive creep behavior of bovine trabecular bone
Bowman, S. M., Keaveny, T. M., Gibson, L. J., Hayes, W. C., & McMahon, T. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90006-x · Cited by 88 · cited 1×
“Trabecular bone has similar creep characteristics as cortical bone and exhibits an initial rapid increase in strain followed by a steady-state regime with a constant creep rate and, finally, another rapid increase in strain just prior to creep fracture (103).”
Fabric dependence of an anisotropic strength criterion
Cowin, S. C. (1986) · Mechanics of Materials · doi:10.1016/0167-6636(86)90022-0 · Cited by 87 · cited 3×
“Early theoretical research on multiaxial failure in trabecular proposed fabric-based yield criteria (119, 120).”
Keaveny, T. M. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.231 · Cited by 86
Bone microdamage: a clinical perspective
Chapurlat, R. D., & Delmas, P. D. (2009) · Osteoporosis International · doi:10.1007/s00198-009-0899-9 · Cited by 85 · cited 1×
“The mechanical effects of osteoporosis therapies, however, differ among the types of therapy (70, 71), and there is concern that long-term use of antiresorptive therapies can result in decreased toughness (48, 72, 73).”
A new model to simulate the elastic properties of mineralized collagen fibril
Fang, Y., Stock, S. R., Haeffner, D. R., Almer, J., Dunand, D. C., & Brinson, L. C. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0223-9 · Cited by 83
The role of the lamellar interface during torsional yielding of human cortical bone
Jepsen, K. J., Davy, D. T., & Krzypow, D. J. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00179-1 · Cited by 81
Tensile Fatigue in Bone: Are Cycles-, or Time to Failure, or Both, Important?
ZIOUPOS, P., CURREY, J. D., & CASINOS, A. (2001) · Journal of Theoretical Biology · doi:10.1006/jtbi.2001.2316 · Cited by 81 · cited 2×
“Cortical bone has greater resistance to fatigue failure in compression than in tension (22) and at higher loading frequencies (23, 24).”
The estimated elastic constants for a single bone osteonal lamella
Yoon, Y. J., & Cowin, S. C. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0072-8 · Cited by 80
Uniaxial yield strains for bovine trabecular bone are isotropic and asymmetric
Chang, W. C. W., Christensen, T. M., Pinilla, T. P., & Keaveny, T. M. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170418 · Cited by 77 · cited 2×
“High-density trabecular bone, such as that from the human femoral neck and bovine proximal tibia, tends to have isotropic yield strains (97, 98).”
Schwiedrzik, J. J., Wolfram, U., & Zysset, P. K. (2013) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0472-5 · Cited by 77
Anisotropy of the fatigue behaviour of cancellous bone
Dendorfer, S., Maier, H. J., Taylor, D., & Hammer, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.037 · Cited by 76 · cited 1×
“The latter result is consistent with the finding that fatigue life is lower for loading oblique to the principal direction (off-axis) versus along the principal direction (on-axis) (118).”
Yamamoto, E., Paul Crawford, R., Chan, D. D., & Keaveny, T. M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.017 · Cited by 72 · cited 2×
“Static and cyclic tests on human trabecular specimens under physiologic loads (750–1,500 microstrain) indicate that the time required for full recovery of residual deformation is more than 20 times longer than the duration of the applied loads (115).”
Improved method for analysis of whole bone torsion tests
Levenston, M. E., Beaupré, G. S., & van der Meulen, M. C. H. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650090919 · Cited by 71
A Damage Model for Nonlinear Tensile Behavior of Cortical Bone
Fondrk, M. T., Bahniuk, E. H., & Davy, D. T. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835084 · Cited by 70 · cited 2×
“The qualitative similarity between this damage–reload of trabecular bone and the behavior of cortical bone loaded in tension (3) suggests that the dominant physical mechanisms underlying the damage behavior act at the nanometer scale.”
Kovacs, C. S. (2017) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3090 · Cited by 70 · cited 1×
“These relationships between porosity and mechanical properties are also notable because of the rapid increases in cortical porosity that can occur (47).”
Orientation dependence of progressive post-yield behavior of human cortical bone in compression
Dong, X. N., Acuna, R. L., Luo, Q., & Wang, X. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.08.034 · Cited by 68
Towards the in vivo prediction of fragility fractures with Raman spectroscopy
Buckley, K., Kerns, J. G., Vinton, J., Gikas, P. D., Smith, C., Parker, A. W., Matousek, P., & Goodship, A. E. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4706 · Cited by 68 · cited 1×
“Raman spectroscopy may be feasible for in vivo evaluation of bone composition (52); however, a firm consensus has yet to emerge on the role of the readouts provided by Raman as indicators of bone fragility.”
The fracture toughness of cancellous bone
Cook, R. B., & Zioupos, P. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.001 · Cited by 66 · cited 1×
“Fracture toughness does appear to append on density (113).”
Landrigan, M. D., Li, J., Turnbull, T. L., Burr, D. B., Niebur, G. L., & Roeder, R. K. (2010) · Bone · doi:10.1016/j.bone.2010.10.160 · Cited by 66 · cited 1×
“Fluorescent and radiopaque stains that label microdamage and larger cracks within the tissue (25, 26) have enabled more in-depth study of the relationships among microcracking, microstructure, and macroscale mechanical properties.”
QCT measures of bone strength at the thoracic and lumbar spine: The Framingham study
Samelson, E. J., Christiansen, B. A., Demissie, S., Broe, K. E., Louie-Gao, Q., Cupples, L. A., Roberts, B. J., Manoharam, R., D'Agostino, J., Lang, T., et al. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1482 · Cited by 65 · cited 1×
“As estimated from FE analyses based on QCT scans, vertebral strength declines with age more quickly in women than in men, and more quickly in the lumbar versus thoracic spine (160), despite the roughly equal proportion of fractures in these two regions.”
Material heterogeneity in cancellous bone promotes deformation recovery after mechanical failure
Torres, A. M., Matheny, J. B., Keaveny, T. M., Taylor, D., Rimnac, C. M., & Hernandez, C. J. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1520539113 · Cited by 64 · cited 1×
“can sustain large bending deformations without catastrophic loss of load-carrying capacity (136, 144).”
Ural, A., & Vashishth, D. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2768377 · Cited by 62 · cited 1×
“Cortical porosity is negatively correlated with Young’s modulus (42), compressive ultimate stress (43), and fracture toughness (44).”
Martínez-Reina, J., Domínguez, J., & García-Aznar, J. M. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0236-4 · Cited by 61
A nonlocal constitutive model for trabecular bone softening in compression
Charlebois, M., Jirásek, M., & Zysset, P. K. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0200-3 · Cited by 61 · cited 1×
“Further research is also needed to build on recent advances in studying the multiaxial mechanical behavior of trabecular bone following yield (124, 125).”
Dependence of elastic constants of an anisotropic porous material upon porosity and fabric
Turner, C. H., & Cowin, S. C. (1987) · Journal of Materials Science · doi:10.1007/bf01161180 · Cited by 60 · cited 1×
“These relations were further developed to uncouple volume fraction from fabric (128) and to ensure positive definiteness of the elasticity tensor a priori (129).”
Heilmeier, U., Cheng, K., Pasco, C., Parrish, R., Nirody, J., Patsch, J. M., Zhang, C. A., Joseph, G. B., Burghardt, A. J., Schwartz, A. V., et al. (2016) · Osteoporosis International · doi:10.1007/s00198-016-3614-7 · Cited by 60 · cited 1×
“In postmenopausal women with type 2 diabetes, cortical porosity is elevated in individuals with a history of fragility fractures compared with nonfracture controls (165).”
Tang, S. Y., & Vashishth, D. (2007) · Bone · doi:10.1016/j.bone.2006.10.031 · Cited by 59 · cited 1×
“It is important to consider that, due to the porous, irregular structure of trabecular bone, some tissue-level strains can be high enough to induce local yielding and a concomitant decline in whole-specimen properties even for low magnitudes of apparent stress (106, 109), consistent with the idea that the presence of…”
Damage in trabecular bone at small strains
Morgan, E., Yeh, O., & Keaveny, T. (2005) · European Journal of Morphology · doi:10.1080/09243860500095273 · Cited by 59 · cited 1×
“It is important to consider that, due to the porous, irregular structure of trabecular bone, some tissue-level strains can be high enough to induce local yielding and a concomitant decline in whole-specimen properties even for low magnitudes of apparent stress (106, 109), consistent with the idea that the presence of…”
Self-citationOsteon interfacial strength and histomorphometry of equine cortical bone
Bigley, R. F., Griffin, L. V., Christensen, L., & Vandenbosch, R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.006 · Cited by 58 · cited 1×
“So-called pull-out and push-out tests indicate that the interfacial strength of the cement line is lower than the shear strength of the osteonal lamellae (34, 35).”
Local strain and damage mapping in single trabeculae during three-point bending tests
Jungmann, R., Szabo, M. E., Schitter, G., Yue-Sing Tang, R., Vashishth, D., Hansma, P. K., & Thurner, P. J. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.12.009 · Cited by 57 · cited 1×
“6% and differs in compression versus tension (108); however, estimates from finite element (FE) models suggest that the threshold for damage initiation is lower (107).”
Heterogeneity of yield strain in low-density versus high-density human trabecular bone
Bevill, G., Farhamand, F., & Keaveny, T. M. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.023 · Cited by 57 · cited 2×
“High-density trabecular bone, such as that from the human femoral neck and bovine proximal tibia, tends to have isotropic yield strains (97, 98).”
Goda, I., & Ganghoffer, J.-F. (2015) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2014.10.007 · Cited by 51
A fabric-dependent fracture criterion for bone
Pietruszczak, S., Inglis, D., & Pande, G. N. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00096-2 · Cited by 51
A multidimensional anisotropic strength criterion based on Kelvin modes
Arramon, Y. P., Mehrabadi, M. M., Martin, D. W., & Cowin, S. C. (2000) · International Journal of Solids and Structures · doi:10.1016/s0020-7683(98)00338-2 · Cited by 51
Moesen, M., Cardoso, L., & Cowin, S. C. (2012) · Mechanics of Materials · doi:10.1016/j.mechmat.2012.07.004 · Cited by 49 · cited 9×
“Cowin SC. Fabric dependence of an anisotropic strength criterion.”
InfluentialFatigue Microdamage in Bovine Trabecular Bone
Moore, T. L. A., & Gibson, L. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1631584 · Cited by 47 · cited 2×
“Cyclic compressive loading of trabecular bone can cause loss of stiffness and strength as well as the accumulation of residual strain even for low levels of applied load (114, 115).”
Specimen-specific multi-scale model for the anisotropic elastic constants of human cortical bone
Deuerling, J. M., Yue, W., Espinoza Orías, A. A., & Roeder, R. K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.002 · Cited by 47
Levrero-Florencio, F., Margetts, L., Sales, E., Xie, S., Manda, K., & Pankaj, P. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.04.008 · Cited by 46
Shi, X., Sherry Liu, X., Wang, X., Edward Guo, X., & Niebur, G. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.05.032 · Cited by 45 · cited 2×
“The propagation of damage and yielding in trabecular bone is also anisotropic in a manner that relates to the orientation and local thickness of the trabeculae (112).”
Litniewski, J. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.06.009 · Cited by 45 · cited 1×
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
Modeling the onset and propagation of trabecular bone microdamage during low-cycle fatigue
Kosmopoulos, V., Schizas, C., & Keller, T. S. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.10.020 · Cited by 44 · cited 1×
“The mechanisms of failure in fatigue appear to occur at the nanoscale (116).”
Novel method to analyze post-yield mechanical properties at trabecular bone tissue level
Carretta, R., Luisier, B., Bernoulli, D., Stüssi, E., Müller, R., & Lorenzetti, S. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.12.003 · Cited by 43 · cited 2×
“can sustain large bending deformations without catastrophic loss of load-carrying capacity (136, 144).”
Turnbull, T. L., Baumann, A. P., & Roeder, R. K. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.06.022 · Cited by 41 · cited 1×
“Changes in porosity account for more than 75% of the variability in the strength of the cortical bone (45), and fatigueinduced microdamage located near cortical pores may be more likely to lead to fracture than that located in regions of high mineral content (46).”
Susceptibility of aging human bone to mixed-mode fracture increases bone fragility
George, W. T., & Vashishth, D. (2006) · Bone · doi:10.1016/j.bone.2005.08.002 · Cited by 40 · cited 1×
“Multiaxial loading can lead to more severe reductions in stiffness (27) and fatigue life (28) as compared to uniaxial loading.”
An Alternative Fabric-based Yield and Failure Criterion for Trabecular Bone
Zysset, P., & Rincón, L. (2006) · Mechanics of Biological Tissue · doi:10.1007/3-540-31184-x_33 · Cited by 39
Hussein, A. I., Jackman, T. M., Morgan, S. R., Barest, G. D., & Morgan, E. F. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2417-3 · Cited by 39
Self-citation(2005) · PubMed · Cited by 39
Osima, M., Kral, R., Borgen, T. T., Høgestøl, I. K., Joakimsen, R. M., Eriksen, E. F., & Bjørnerem, Å. (2017) · Bone · doi:10.1016/j.bone.2017.01.037 · Cited by 39 · cited 1×
“However, an association between cortical porosity and diabetes may depend on anatomic site (166), and not all measures of bone microstructure are deficient in diabetics versus controls (167).”
Gauthier, R., Follet, H., Langer, M., Meille, S., Chevalier, J., Rongiéras, F., Peyrin, F., & Mitton, D. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.03.015 · Cited by 38 · cited 1×
“Values of KIC, the fracture toughness for so-called mode I loading (tensile loading), range between 2 and 6 MPa√m and tend to be lower for longitudinal than for transverse fracture (15, 16) and to be lower at high strain rates (17, 18).”
Lambers, F. M., Bouman, A. R., Tkachenko, E. V., Keaveny, T. M., & Hernandez, C. J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.10.011 · Cited by 36 · cited 1×
“For example, more microdamage is found in regions with low volume fraction and high SMI—indicating a predominance of trabecular rods (110, 111).”
Femoral Strength Changes Faster With Age Than BMD in Both Women and Men: A Biomechanical Study
Rezaei, A., & Dragomir-Daescu, D. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2572 · Cited by 36
Modeling of Stiffness and Strength of Bone at Nanoscale
Abueidda, D., Sabet, F. A., & Jasiuk, I. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4036314 · Cited by 36
The effect of osteoporosis treatments on fatigue properties of cortical bone tissue
Brock, G. R., Chen, J. T., Ingraffea, A. R., MacLeay, J., Pluhar, G. E., Boskey, A. L., & van der Meulen, M. C. H. (2015) · Bone Reports · doi:10.1016/j.bonr.2014.10.004 · Cited by 33 · cited 1×
“The mechanical effects of osteoporosis therapies, however, differ among the types of therapy (70, 71), and there is concern that long-term use of antiresorptive therapies can result in decreased toughness (48, 72, 73).”
Microscopic assessment of bone toughness using scratch tests
Kataruka, A., Mendu, K., Okeoghene, O., Puthuvelil, J., & Akono, A.-T. (2017) · Bone Reports · doi:10.1016/j.bonr.2016.12.001 · Cited by 28 · cited 1×
“Preliminary values of fracture toughness at the microscale appear to be similar to those measured at the macroscale (41).”
Non-destructive characterization of microdamage in cortical bone using low field pulsed NMR
Nicolella, D. P., Ni, Q., & Chan, K. S. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.007 · Cited by 25 · cited 1×
“In vitro mechanical tests have found that microdamage is associated with a decrease in modulus (9, 10), and a weak inverse relationship between fracture toughness and microdamage density has been reported (11).”
Moderate chronic kidney disease impairs bone quality in C57Bl/6J mice
Heveran, C. M., Ortega, A. M., Cureton, A., Clark, R., Livingston, E. W., Bateman, T. A., Levi, M., King, K. B., & Ferguson, V. L. (2016) · Bone · doi:10.1016/j.bone.2016.02.006 · Cited by 25 · cited 1×
“Alteration in mineral content and in the spatial distribution of mineral, as in Paget’s disease, vitamin D deficiency, and chronic kidney disease, have also been linked to deficits in stiffness or toughness, or to changes in the manner of crack propagation (19, 77).”
Mixed-mode toughness of human cortical bone containing a longitudinal crack in far-field compression
Olvera, D., Zimmermann, E. A., & Ritchie, R. O. (2012) · Bone · doi:10.1016/j.bone.2011.11.004 · Cited by 24 · cited 1×
“However, mixed-mode loading involving mode I (tension) and mode II (shear) is associated with greater fracture toughness than mode I alone (29).”
Nekkanty, S., Yerramshetty, J., Kim, D.-G., Zauel, R., Johnson, E., Cody, D. D., & Yeni, Y. N. (2010) · Bone · doi:10.1016/j.bone.2010.07.001 · Cited by 23
Goff, M. G., Lambers, F. M., Sorna, R. M., Keaveny, T. M., & Hernandez, C. J. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.10.023 · Cited by 20 · cited 1×
“6% and differs in compression versus tension (108); however, estimates from finite element (FE) models suggest that the threshold for damage initiation is lower (107).”
(1997) · Cellular Solids · doi:10.1017/cbo9781139878326.013 · Cited by 16
A damage assessment model for cadaveric cortical bone subjected to fatigue cycles
Varvani-Farahani, A., & Najmi, H. (2010) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2009.08.002 · Cited by 16
Carretta, R., Stüssi, E., Müller, R., & Lorenzetti, S. (2015) · BioMed Research International · doi:10.1155/2015/457371 · Cited by 14 · cited 1×
“Recent research indicates that the mechanical properties of trabecular tissue, especially the ultimate strain and toughness, are correlated Raman spectroscopic readouts such as collagen cross-linking (140).”
Elastic Anisotropy of Trabecular Bone in the Elderly Human Vertebra
Unnikrishnan, G. U., Gallagher, J. A., Hussein, A. I., Barest, G. D., & Morgan, E. F. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4031415 · Cited by 13 · cited 1×
“Note, however, that in regions of the vertebrae with low volume fraction, the trabecular network may be too sparse and spatially heterogeneous to allow proper definition of the type of anisotropy and the material properties (96).”
Self-citationPauchard, Y., Mattmann, C., Kuhn, A., Gasser, J. A., & Boyd, S. K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.07.036 · Cited by 12
Effects of fatigue induced damage on the longitudinal fracture resistance of cortical bone
Fletcher, L., Codrington, J., & Parkinson, I. (2014) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-014-5213-5 · Cited by 12 · cited 1×
“Fatigue loading results in progressive degradation of mechanical properties such as fracture toughness, modulus, and strength (20, 21).”
Campbell, G. M., Tiwari, S., Picke, A.-K., Hofbauer, C., Rauner, M., Morlock, M. M., Hofbauer, L. C., & Glüer, C.-C. (2016) · Bone · doi:10.1016/j.bone.2016.08.003 · Cited by 11 · cited 2×
“evidence also indicates that diabetes is associated with lower bone toughness as compared with normal cortical bone (70, 74) and that this difference may be related to heightened accumulation of AGEs in diabetic bone (75).”
Post-yield relaxation behavior of bovine cancellous bone
Burgers, T. A., Lakes, R. S., García-Rodríguez, S., Piller, G. R., & Ploeg, H.-L. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.005 · Cited by 10 · cited 1×
“Both stress- and strain-dependent effects in stress–relaxation experiments have been observed (102), indicating that trabecular bone is technically nonlinearly viscoelastic.”
Cited by
Porous scaffolds for bone regeneration
Abbasi, N., Hamlet, S., Love, R. M., & Nguyen, N.-T. (2020) · Journal of Science: Advanced Materials and Devices · doi:10.1016/j.jsamd.2020.01.007 · Cited by 858
“variations in compressive strength and tensile values in different regions of bone [80].”
BackgroundRecent Progress on Polymer Materials for Additive Manufacturing
Tan, L. J., Zhu, W., & Zhou, K. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003062 · Cited by 740
Applications of Magnesium and Its Alloys: A Review
Tan, J., & Ramakrishna, S. (2021) · Applied Sciences · doi:10.3390/app11156861 · Cited by 350
Natural and Synthetic Polymers for Bone Scaffolds Optimization
Donnaloja, F., Jacchetti, E., Soncini, M., & Raimondi, M. T. (2020) · Polymers · doi:10.3390/polym12040905 · Cited by 324
“Native bone tissue physical characteristics are summarized in Table 1 [3,4].”
BackgroundStrategies for Bone Regeneration: From Graft to Tissue Engineering
Battafarano, G., Rossi, M., De Martino, V., Marampon, F., Borro, L., Secinaro, A., & Del Fattore, A. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22031128 · Cited by 295
“(with a porosity ranging from 40% to 95% [4]) and less dense than cortical bone, giving this spongy bone a more flexible and weaker structure.”
Background
Metadata
- Authors
- Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I.
- Affiliations
- Boston University (US)
- Corresponding author
- Morgan, Elise F.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2018-06-04
- Volume
- 20
- Issue
- 1
- Pages
- 119-143
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- PMC
- PMC6053074
- OpenAlex
- W2807165335
- Semantic Scholar
- a169125cebb03ba7d2bb7a6ffa25b4106fcdfc55
- Cited by
- 1,026
- References
- 174
- Citations by year
- 2026: 163 · 2025: 223 · 2024: 194 · 2023: 150 · 2022: 136 · 2021: 114 · 2020: 37 · 2019: 8 · 2018: 1
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- OpenBU (Boston University) (submittedVersion, cc-by)
- Funders
- National Science Foundation (1266243)
- National Institutes of Health (AR054620)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R56AR054620, R01AR054620)
- Division of Civil, Mechanical and Manufacturing Innovation
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- bone mechanical properties, bone mechanics, osteoporosis, diabetes mellitus, cortical bone, trabecular bone, elasticity, yield, fracture, fatigue (material), damages, bone mineral density, porosity, crosslinking, aging
- MeSH terms
- Aging, Bone and Bones, Bone Diseases, Diabetes Mellitus, Elasticity, Humans, Models, Theoretical, Osteoporosis, Quality of Life, Stress, Mechanical, Viscosity, Bone Density, Porosity, Anisotropy, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.