Photoacoustic Microscopy and Computed Tomography: From Bench to Bedside
Open accessThe DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
Photoacoustic imaging (PAI) of biological tissue has seen immense growth in the past decade, providing unprecedented spatial resolution and functional information at depths in the optical diffusive regime. PAI uniquely combines the advantages of optical excitation and those of acoustic detection. The hybrid imaging modality features high sensitivity to optical absorption and wide scalability of spatial resolution with the desired imaging depth. Here we first summarize the fundamental principles underpinning the technology, then highlight its practical implementation, and finally discuss recent advances toward clinical translation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 1×
“In PAT, the depth-to-resolution ratio is ~ 200 (10), nearly two orders of magnitude higher than that in diffuse optical tomography (11).”
BackgroundSelf-citationPhotoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationFunctional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700 · cited 1×
“In particular, the demonstration of functional PA imaging (PAI) propelled the field into a fast developing stage (7).”
BackgroundSelf-citationUniversal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Self-citationBiomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Self-citationDiagnostic Ultrasound Imaging: Inside Out
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07261-7 · Cited by 1,093
Circulating tumor cells: approaches to isolation and characterization
Yu, M., Stott, S., Toner, M., Maheswaran, S., & Haber, D. A. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201010021 · Cited by 1,089 · cited 1×
“Detection of CTCs plays a critical role in evaluating metastasis as well as cancer recurrence and therapeutic efficacy (101).”
BackgroundOn the production and reproduction of sound by light
Bell, A. G. (1880) · American Journal of Science · doi:10.2475/ajs.s3-20.118.305 · Cited by 1,082 · cited 2×
“(1) Here κ is the isothermal compressibility (Pa−1), and β is the thermal coefficient of volume expansion (K−1).”
Background
Cited by
Tutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Self-citationPrecise nanomedicine for intelligent therapy of cancer
Chen, H., Gu, Z., An, H., Chen, C., Chen, J., Cui, R., Chen, S., Chen, W., Chen, X., Chen, X., et al. (2018) · Science China Chemistry · doi:10.1007/s11426-018-9397-5 · Cited by 409
Ultrasensitive plano-concave optical microresonators for ultrasound sensing
Guggenheim, J. A., Li, J., Allen, T. J., Colchester, R. J., Noimark, S., Ogunlade, O., Parkin, I. P., Papakonstantinou, I., Desjardins, A. E., Zhang, E. Z., et al. (2017) · Nature Photonics · doi:10.1038/s41566-017-0027-x · Cited by 391
Photoacoustic Imaging-Trackable Magnetic Microswimmers for Pathogenic Bacterial Infection Treatment
Xie, L., Pang, X., Yan, X., Dai, Q., Lin, H., Ye, J., Cheng, Y., Zhao, Q., Ma, X., Zhang, X., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b06731 · Cited by 261
Deep learning for biomedical photoacoustic imaging: A review
Gröhl, J., Schellenberg, M., Dreher, K., & Maier-Hein, L. (2021) · Photoacoustics · doi:10.1016/j.pacs.2021.100241 · Cited by 248
“Photoacoustic imaging (PAI) is a comparatively young and rapidly emerging imaging modality that promises real-time, noninvasive, and radiation-free measurement of optical tissue properties [1].”
BackgroundRecent Advances of Light-Mediated Theranostics
Ai, X., Mu, J., & Xing, B. (2016) · Theranostics · doi:10.7150/thno.16088 · Cited by 226
“Recently, a brand-new technique, PA imaging, which integrates NIR light excitation and ultrasound imaging into one system, has been developed as a new kind of imaging modality to provide deep-tissue penetration and strong PA signals from endogenous or exogenous contrast agents with high resolution in living systems [1…”
BackgroundRecent advances toward preclinical and clinical translation of photoacoustic tomography: a review
Upputuri, P. K., & Pramanik, M. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.4.041006 · Cited by 223
Guo, W., Guo, C., Zheng, N., Sun, T., & Liu, S. (2017) · Advanced Materials · doi:10.1002/adma.201604157 · Cited by 215
A Phosphorus Phthalocyanine Formulation with Intense Absorbance at 1000 nm for Deep Optical Imaging
Zhou, Y., Wang, D., Zhang, Y., Chitgupi, U., Geng, J., Wang, Y., Zhang, Y., Cook, T. R., Xia, J., & Lovell, J. F. (2016) · Theranostics · doi:10.7150/thno.14555 · Cited by 180
“In comparison, PACT depth-to-resolution ratio is close to 200 [23].”
Background
Metadata
- Authors
- Wang, L. V., & Gao, L.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2014-07-11
- Volume
- 16
- Issue
- 1
- Pages
- 155-185
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2100562442
- Cited by
- 246
- References
- 88
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.