Abstract
Photoacoustic imaging (PAI) of biological tissue has seen immense growth in the past decade, providing unprecedented spatial resolution and functional information at depths in the optical diffusive regime. PAI uniquely combines the advantages of optical excitation and those of acoustic detection. The hybrid imaging modality features high sensitivity to optical absorption and wide scalability of spatial resolution with the desired imaging depth. Here we first summarize the fundamental principles underpinning the technology, then highlight its practical implementation, and finally discuss recent advances toward clinical translation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 1×
“In PAT, the depth-to-resolution ratio is ~ 200 (10), nearly two orders of magnitude higher than that in diffuse optical tomography (11).”
BackgroundSelf-citationPhotoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationFunctional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Self-citationWang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700 · cited 1×
“In particular, the demonstration of functional PA imaging (PAI) propelled the field into a fast developing stage (7).”
BackgroundSelf-citationUniversal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Self-citationBiomedical Optics, Principles and Imaging
Wang, L. V., Wu, H.-I., & Masters, B. R. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2976007 · Cited by 1,178
Self-citationDiagnostic Ultrasound Imaging: Inside Out
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07261-7 · Cited by 1,093
Circulating tumor cells: approaches to isolation and characterization
Yu, M., Stott, S., Toner, M., Maheswaran, S., & Haber, D. A. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201010021 · Cited by 1,089 · cited 1×
“Detection of CTCs plays a critical role in evaluating metastasis as well as cancer recurrence and therapeutic efficacy (101).”
BackgroundOn the production and reproduction of sound by light
Bell, A. G. (1880) · American Journal of Science · doi:10.2475/ajs.s3-20.118.305 · Cited by 1,082 · cited 2×
“(1) Here κ is the isothermal compressibility (Pa−1), and β is the thermal coefficient of volume expansion (K−1).”
BackgroundOptical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763 · cited 1×
“To release the dependence of resolution on acoustic frequency, OR-PAM utilizes focused light to spatially confine the excitation, resulting in an optical diffraction-limited resolution in the lateral direction (29).”
MethodSelf-citationQuantitative spectroscopic photoacoustic imaging: a review
Cox, B., Laufer, J. G., Arridge, S. R., & Beard, P. C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061202 · Cited by 720
Zhang, E., Laufer, J. G., & Beard, P. C. (2008) · Applied Optics · doi:10.1364/ao.47.000561 · Cited by 611
Tutorial on Photoacoustic Microscopy and Computed Tomography
Wang, L. V. (2008) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.913398 · Cited by 607 · cited 2×
“The PA flowmetry is superior to other Doppler-effect-based methods, such as functional OCT (91) or Doppler ultrasonography (92), in blood flow measurement because PA provides unique 100% optical absorption contrast (8) while purely optical or ultrasonic approaches depend on optical or ultrasonic scattering, respective…”
MethodSelf-citationCoherent Nonlinear Optical Imaging: Beyond Fluorescence Microscopy
Min, W., Freudiger, C. W., Lu, S., & Xie, X. S. (2011) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103512 · Cited by 604 · cited 1×
“Akin to FRET microscopy, the imaging depth of conventional stimulated Raman (SR) microscopy is also limited by light diffusion (109).”
MethodIn vivo magnetic enrichment and multiplex photoacoustic detection of circulating tumour cells
Galanzha, E. I., Shashkov, E. V., Kelly, T., Kim, J.-W., Yang, L., & Zharov, V. P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.333 · Cited by 575 · cited 1×
“The positive contrast in PAFC can be used to detect higher absorption targets than red blood cells (RBCs) such as melanoma cells (100) or cells labeled with nanoparticles (99), while the negative contrast can be used to sense lower absorption targets as in the case of platelets or white blood cells.”
BackgroundLaser optoacoustic imaging system for detection of breast cancer
Ermilov, S. A., Khamapirad, T., Conjusteau, A., Leonard, M. H., Lacewell, R., Mehta, K., Miller, T., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3086616 · Cited by 493 · cited 4×
“Three representative instruments, LOIS-64 (112), modified Philips iU22 (118), and Twente PA mammoscope (114; 119) are shown in Fig.”
MethodInfluentialSecond-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed
Hu, S., Maslov, K., & Wang, L. V. (2011) · Optics Letters · doi:10.1364/ol.36.001134 · Cited by 429
Self-citationSimultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo
Yang, J.-M., Favazza, C., Chen, R., Yao, J., Cai, X., Maslov, K., Zhou, Q., Shung, K. K., & Wang, L. V. (2012) · Nature Medicine · doi:10.1038/nm.2823 · Cited by 429 · cited 2×
“By using this PAE probe, an angular field-of-view of 270 degrees and a depth of over 5 mm were achieved in a rabbit esophagus imaging experiment (54).”
MethodSelf-citationBiomedical Applications of Photoacoustic Imaging with Exogenous Contrast Agents
Luke, G. P., Yeager, D., & Emelianov, S. Y. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0449-4 · Cited by 418 · cited 1×
“One may refer to a more specific article for this topic (128).”
BackgroundIn vivo dark-field reflection-mode photoacoustic microscopy
Maslov, K., Stoica, G., & Wang, L. V. (2005) · Optics Letters · doi:10.1364/ol.30.000625 · Cited by 413 · cited 1×
“While the bright-field approach can deliver higher fluence to a targeted volume (39), the dark-field method has an edge on reducing surface interference to deeper PA signals (41).”
BackgroundSelf-citationReconstructions in limited‐view thermoacoustic tomography
Xu, Y., Wang, L. V., Ambartsoumian, G., & Kuchment, P. (2004) · Medical Physics · doi:10.1118/1.1644531 · Cited by 398 · cited 1×
“To accurately render an object’s boundaries in two-dimensional (2D) PACT, a detector array must cover at least a π-arc directional view (44).”
MethodSelf-citationZhang, H. F., Maslov, K., Sivaramakrishnan, M., Stoica, G., & Wang, L. V. (2007) · Applied Physics Letters · doi:10.1063/1.2435697 · Cited by 380 · cited 1×
“After that, one can derive the concentrations of oxyhemoglobin and deoxy-hemoglobin by applying a spectral unmixing algorithm (70), and calculate sO2 distribution by using Eq.”
MethodSelf-citationBateman, R. M., Sharpe, M. D., & Ellis, C. G. (2003) · Critical Care · doi:10.1186/cc2353 · Cited by 372 · cited 1×
“The blood oxygenation can potentially be used to measure hypermetabolism, a hallmark of cancer (69).”
BackgroundOptical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364 · cited 2×
“Despite CW lasers having a lower SNR, it is worth noting that, compared with pulsed lasers, they have the advantage of being compact and less costly, which supports the use of frequency-domain PAI in point-of-care applications (28).”
BackgroundPhotoacoustic imaging and temperature measurement for photothermal cancer therapy
Shah, J., Park, S., Aglyamov, S., Larson, T., Ma, L., Sokolov, K., Johnston, K., Milner, T., & Emelianov, S. Y. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2940362 · Cited by 354
Photoacoustic monopole radiation in one, two, and three dimensions
Diebold, G. J., Sun, T., & Khan, M. I. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.3384 · Cited by 353 · cited 1×
“7 are affected by the geometry of an absorber (14), the laser pulse duration (14), the mass density ratio ρ̂ and sound speed ratio v̂s of the absorber to surrounding media (13), and the ultrasonic attenuation (15).”
BackgroundVolumetric real-time multispectral optoacoustic tomography of biomarkers
Razansky, D., Buehler, A., & Ntziachristos, V. (2011) · Nature Protocols · doi:10.1038/nprot.2011.351 · Cited by 309 · cited 1×
“Ultrasonic transducer arrays with various populating patterns, such as line (47), half ring (48; 49), full-ring (50; 51) and hemisphere (52), have been employed and demonstrated in both animal and clinical applications.”
MethodIn vivo preclinical photoacoustic imaging of tumor vasculature development and therapy
Laufer, J. G., Zhang, E. Z., Treeby, B. E., Cox, B. T., Beard, P. C., Johnson, P., & Pedley, B. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056016 · Cited by 308 · cited 6×
“Due to its 2D parallel acquisition, phase contrast microscopy is superior to Mach–Zehnder interferometry in terms of imaging speed for OD-PAT (59).”
BackgroundInfluentialPhotoacoustic angiography of the breast
Kruger, R. A., Lam, R. B., Reinecke, D. R., Del Rio, S. P., & Doyle, R. P. (2010) · Medical Physics · doi:10.1118/1.3497677 · Cited by 302 · cited 1×
“Ultrasonic transducer arrays with various populating patterns, such as line (47), half ring (48; 49), full-ring (50; 51) and hemisphere (52), have been employed and demonstrated in both animal and clinical applications.”
MethodDeeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system
Kim, C., Erpelding, T. N., Jankovic, L., Pashley, M. D., & Wang, L. V. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000278 · Cited by 289 · cited 1×
“Preliminary data demonstrated that PAT has both the required penetration depth and spatial resolution for SLN mapping (126; 127), enabling a clinician to use noninvasive diagnostic methods to stage the axilla without the morbidity of a surgery.”
MethodSelf-citationManohar, S., Vaartjes, S. E., van Hespen, J. C. G., Klaase, J. M., van den Engh, F. M., Steenbergen, W., & van Leeuwen, T. G. (2007) · Optics Express · doi:10.1364/oe.15.012277 · Cited by 287 · cited 1×
“By using the Twente photoacoustic mammoscope, the PAT images in 4 of 6 cases of patients with symptomatic breasts revealed higher intensity regions attributed by tumor-associated vascular distributions (125).”
MethodSubwavelength-resolution label-free photoacoustic microscopy of optical absorption in vivo
Zhang, C., Maslov, K., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.003195 · Cited by 281 · cited 1×
“Unlike x-ray imaging, OR-PAM can either work in back-reflection (29–33) or transmission mode (34; 35), with typical setups shown in Fig.”
MethodSelf-citationGalanzha, E. I., Shashkov, E. V., Spring, P. M., Suen, J. Y., & Zharov, V. P. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4900 · Cited by 259 · cited 1×
“The positive contrast in PAFC can be used to detect higher absorption targets than red blood cells (RBCs) such as melanoma cells (100) or cells labeled with nanoparticles (99), while the negative contrast can be used to sense lower absorption targets as in the case of platelets or white blood cells.”
BackgroundPhotoacoustic ophthalmoscopy for in vivo retinal imaging
Jiao, S., Jiang, M., Hu, J., Fawzi, A., Zhou, Q., Shung, K. K., Puliafito, C. A., & Zhang, H. F. (2010) · Optics Express · doi:10.1364/oe.18.003967 · Cited by 258 · cited 1×
“Combining PAT with ultrasonography or OCT will be highly useful in clinical diagnosis (116; 130; 131).”
MethodSentinel Lymph Nodes in the Rat: Noninvasive Photoacoustic and US Imaging with a Clinical US System
Erpelding, T. N., Kim, C., Pramanik, M., Jankovic, L., Maslov, K., Guo, Z., Margenthaler, J. A., Pashley, M. D., & Wang, L. V. (2010) · Radiology · doi:10.1148/radiol.10091772 · Cited by 252 · cited 3×
“To take advantage of the high sensitivity of PAT to optical absorption, a handheld arraybased PAT probe was developed for SLN mapping (116; 117).”
BackgroundMethodSelf-citationThermoacoustic and photoacoustic sensing of temperature
Pramanik, M., & Wang, L. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3247155 · Cited by 233
Self-citationMicrowave-induced acoustic imaging of biological tissues
Wang, L. V., Zhao, X., Sun, H., & Ku, G. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149986 · Cited by 230 · cited 1×
“In biomedicine, the application of the PA effect started in the 1970s (4); however, not until the last decade of the 20th century were breakthroughs achieved in demonstrating the PA effect in optically scattering media and biological tissue (5; 6).”
BackgroundSelf-citationYang, J.-M., Maslov, K., Yang, H.-C., Zhou, Q., Shung, K. K., & Wang, L. V. (2009) · Optics Letters · doi:10.1364/ol.34.001591 · Cited by 229 · cited 8×
“3.4 Photoacoustic endoscopy (PAE) PAT of internal organs through endoscopy is referred to as PAE (53).”
MethodInfluentialSelf-citationIn vivo label-free photoacoustic microscopy of cell nuclei by excitation of DNA and RNA
Yao, D.-K., Maslov, K., Shung, K. K., Zhou, Q., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.004139 · Cited by 225 · cited 1×
“The autocorrelation function is defined as G(τ ) = 〈δp(t)δp(t + τ )〉 / 〈p(t)〉2 , (38) where δp(t) = p(t) − 〈p(t)〉 is the fluctuation of PA signal p(t), and 〈p(t)〉 denotes an ensemble average.”
Self-citationThe Twente Photoacoustic Mammoscope: system overview and performance
Manohar, S., Kharine, A., van Hespen, J. C. G., Steenbergen, W., & van Leeuwen, T. G. J. M. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/11/007 · Cited by 205 · cited 1×
“Three representative instruments, LOIS-64 (112), modified Philips iU22 (118), and Twente PA mammoscope (114; 119) are shown in Fig.”
MethodIn vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth
Yao, J., Maslov, K. I., Shi, Y., Taber, L. A., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.001419 · Cited by 200 · cited 1×
“An alternative is based on the Doppler broadening of bandwidth, an effect due to the frequency difference between the extremities of the received acoustic wavefront from an absorber moving orthogonal to the transducer axis (90).”
BackgroundSelf-citationHeijblom, M., Piras, D., Xia, W., van Hespen, J. C. G., Klaase, J. M., van den Engh, F. M., van Leeuwen, T. G., Steenbergen, W., & Manohar, S. (2012) · Optics Express · doi:10.1364/oe.20.011582 · Cited by 199 · cited 2×
“Three representative instruments, LOIS-64 (112), modified Philips iU22 (118), and Twente PA mammoscope (114; 119) are shown in Fig.”
MethodOptimization of optode arrangements for diffuse optical tomography: A singular-value analysis
Culver, J. P., Ntziachristos, V., Holboke, M. J., & Yodh, A. G. (2001) · Optics Letters · doi:10.1364/ol.26.000701 · Cited by 183 · cited 1×
“In PAT, the depth-to-resolution ratio is ~ 200 (10), nearly two orders of magnitude higher than that in diffuse optical tomography (11).”
BackgroundDeep reflection-mode photoacoustic imaging of biological tissue
Song, K. H., & Wang, L. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2818045 · Cited by 181 · cited 1×
“8 mm with a 50 MHz ultrasonic transducer (39), while a lateral resolution of 560 μm was reported at a depth of 38 mm by using a 5 MHz ultrasonic transducer (43).”
MethodSelf-citationKoelliker, S. L., Chung, M. A., Mainiero, M. B., Steinhoff, M. M., & Cady, B. (2007) · Radiology · doi:10.1148/radiol.2463061463 · Cited by 181 · cited 1×
“However, ultrasonography cannot provide a sufficient contrast to identify SLN, reducing the sensitivity of ultrasound-guided fine needle aspiration biopsy (124).”
BackgroundZharov, V. P., Galanzha, E. I., Shashkov, E. V., Kim, J.-W., Khlebtsov, N. G., & Tuchin, V. V. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793746 · Cited by 177
FRET microscopy: from principle to routine technology in cell biology
PIETRASZEWSKA-BOGIEL, A., & GADELLA, T. W. J. (2011) · Journal of Microscopy · doi:10.1111/j.1365-2818.2010.03437.x · Cited by 177 · cited 1×
“Forster resonance energy transfer (FRET) microscopy (106) is routinely used in modern biological research.”
Photoacoustic Doppler Effect from Flowing Small Light-Absorbing Particles
Fang, H., Maslov, K., & Wang, L. V. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.184501 · Cited by 171 · cited 1×
“Analogous to the ultrasonic Doppler effect, the PA Doppler (PAD) effect was observed and utilized in axial speed measurement (87; 88).”
MethodSelf-citationPhotoacoustic imaging of biological tissue with intensity-modulated continuous-wave laser
Maslov, K., & Wang, L. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904965 · Cited by 168 · cited 1×
“16) can be measured with a high SNR by lock-in detection (20).”
BackgroundSelf-citationLabel-Free Bond-Selective Imaging by Listening to Vibrationally Excited Molecules
Wang, H.-W., Chai, N., Wang, P., Hu, S., Dou, W., Umulis, D., Wang, L. V., Sturek, M., Lucht, R., & Cheng, J.-X. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.238106 · Cited by 163 · cited 1×
“Benefit from low acoustic scattering, one millimeter penetration depth has been reported in an in vivo SR imaging experiment (111).”
BackgroundSelf-citationGalanzha, E. I., & Zharov, V. P. (2012) · Methods · doi:10.1016/j.ymeth.2012.06.009 · Cited by 159
Wide-field fast-scanning photoacoustic microscopy based on a water-immersible MEMS scanning mirror
Yao, J., Wang, L., Yang, J.-M., Gao, L. S., Maslov, K. I., Wang, L. V., Huang, C.-H., & Zou, J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.8.080505 · Cited by 159 · cited 1×
“, 100 kHz) and a water-immersible microelectromechanical systems (MEMS) scanning mirror, a B-scan rate up to 400 Hz over a 3-mm scanning range was reported (32).”
BackgroundSelf-citationZhang, C., Maslov, K., Yao, J., & Wang, L. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.11.116016 · Cited by 137
Self-citationStatistics and Related Topics in Single-Molecule Biophysics
Qian, H., & Kou, S. C. (2014) · Annual Review of Statistics and Its Application · doi:10.1146/annurev-statistics-022513-115535 · Cited by 132
Detection of ultrawide-band ultrasound pulses in optoacoustic tomography
Андреев, В. Г., Karabutov, A. A., & Oraevsky, A. A. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1244756 · Cited by 131 · cited 3×
“(26) Ultimately, the choice of the acoustic bandwidth is based on the desired imaging depths.”
BackgroundInfluentialKruger, R. A. (1994) · Medical Physics · doi:10.1118/1.597367 · Cited by 130 · cited 1×
“In biomedicine, the application of the PA effect started in the 1970s (4); however, not until the last decade of the 20th century were breakthroughs achieved in demonstrating the PA effect in optically scattering media and biological tissue (5; 6).”
BackgroundGalanzha, E. I., Shashkov, E. V., Tuchin, V. V., & Zharov, V. P. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20587 · Cited by 127 · cited 1×
“By contrast, PAFC has the capability to measure a blood volume of up to a patient’s entire blood volume in vivo, resulting in a significant improvement in sensitivity (102).”
BackgroundPhotoacoustic tomography through a whole adult human skull with a photon recycler
Nie, L., Cai, X., Maslov, K., Garcia‐Uribe, A., Anastasio, M. A., & Wang, L. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.11.110506 · Cited by 123 · cited 7×
“4 were achieved in an ex vivo experiment (115).”
BackgroundInfluentialSelf-citationReflection-mode submicron-resolution in vivo photoacoustic microscopy
Zhang, C., Maslov, K., Hu, S., Wang, L. V., Chen, R., Zhou, Q., & Shung, K. K. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.2.020501 · Cited by 119 · cited 1×
“(32) With fluence correction and system calibration, the following quantity S is recovered: S = k p F0 = kμaBT + kμaA, (33)”
BackgroundSelf-citationNoninvasive label-free imaging of microhemodynamics by optical-resolution photoacoustic microscopy
Hu, S., Maslov, K., & Wang, L. V. (2009) · Optics Express · doi:10.1364/oe.17.007688 · Cited by 117
Self-citationHuang, C., Nie, L., Schoonover, R. W., Guo, Z., Schirra, C. O., Anastasio, M. A., & Wang, L. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.066016 · Cited by 115 · cited 2×
“However, promising improvements have been achieved in the past few years, raising confidence that PAT can be potentially a highly useful clinical tool for noninvasive functional brain imaging (115; 121; 123).”
BackgroundMethodSelf-citationPure optical photoacoustic microscopy
Xie, Z., Chen, S., Ling, T., Guo, L. J., Carson, P. L., & Wang, X. (2011) · Optics Express · doi:10.1364/oe.19.009027 · Cited by 112 · cited 1×
“7(a)) (65; 66) and Fabry-Perot interferometer (FPI) (Fig.”
Ren, H., Brecke, K. M., Ding, Z., Zhao, Y., Nelson, J. S., & Chen, Z. (2002) · Optics Letters · doi:10.1364/ol.27.000409 · Cited by 110 · cited 6×
“While PAT provides high detection sensitivity to optical absorption, ultrasonography and OCT provide complementary morphologic information based on acoustic and optical scattering, respectively.”
MethodInfluentialKim, C., Erpelding, T. N., Jankovic, L., & Wang, L. V. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2010.0353 · Cited by 104
Self-citationImaging of tumor vasculature using Twente photoacoustic systems
Jose, J., Manohar, S., Kolkman, R. G. M., Steenbergen, W., & van Leeuwen, T. G. J. M. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910025 · Cited by 88
Ke, H., Liu, C., Wang, L. V., Erpelding, T. N., & Jankovic, L. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056010 · Cited by 86 · cited 2×
“Three representative instruments, LOIS-64 (112), modified Philips iU22 (118), and Twente PA mammoscope (114; 119) are shown in Fig.”
BackgroundMethodSelf-citationHeimdal, A., & Torp, H. G. (1997) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.655202 · Cited by 84 · cited 1×
“Slowly flowing RBCs yield small Doppler shifts or bandwidth broadening, which are easily obscured by the phase noise as in OCT (93) or motion of surrounding tissue as in ultrasonography (94).”
BackgroundVideo-rate functional photoacoustic microscopy at depths
Wang, L., Maslov, K., Xing, W., Garcia‐Uribe, A., & Wang, L. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.10.106007 · Cited by 83 · cited 2×
“While the bright-field approach can deliver higher fluence to a targeted volume (39), the dark-field method has an edge on reducing surface interference to deeper PA signals (41).”
BackgroundMethodSelf-citationStimulated Raman photoacoustic imaging
Yakovlev, V. V., Zhang, H. F., Noojin, G. D., Denton, M. L., Thomas, R. J., & Scully, M. O. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012432107 · Cited by 79 · cited 1×
“offers an ideal solution to this problem (110).”
BackgroundSingle-cell photoacoustic thermometry
Gao, L. S., Wang, L., Li, C., Liu, Y., Ke, H., Zhang, C., & Wang, L. V. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.2.026003 · Cited by 79 · cited 18×
“OR-PAM works within the optical ballistic or quasi-ballistic regime.”
BackgroundMethodInfluentialSelf-citationIn vivo flow speed measurement of capillaries by photoacoustic correlation spectroscopy
Chen, S., Xie, Z., Carson, P. L., Wang, X., & Guo, L. J. (2011) · Optics Letters · doi:10.1364/ol.36.004017 · Cited by 76 · cited 1×
“For extremely slow flow measurement, PA correlation spectroscopy (PCS) was exploited due to its high detection sensitivity (95; 96).”
MethodEffects of light scattering on optical-resolution photoacoustic microscopy
Liu, Y., Zhang, C., & Wang, L. V. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.12.126014 · Cited by 76 · cited 1×
“Beyond this depth, the lateral resolution is degraded quickly and becomes acoustically limited (37).”
BackgroundSelf-citationPhotoacoustic computed tomography correcting for heterogeneity and attenuation
Huang, C., Nie, L., Schoonover, R. W., Wang, L. V., & Anastasio, M. A. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061211 · Cited by 72 · cited 1×
“To improve image quality, the ultrasonic attenuation can be accounted for mathematically (18; 19).”
BackgroundSelf-citationFrom Unseen to Seen: Tackling the Global Burden of Uncorrected Refractive Errors
Durr, N. J., Dave, S. R., Lage, E., Marcos, S. C., Thorn, F., & Lim, D. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-105216 · Cited by 67
Photoacoustic Doppler Flow Measurement in Optically Scattering Media
Fang, H., Maslov, K., & Wang, L. V. (2007) · Applied Physics Letters · doi:10.1063/1.2825569 · Cited by 64 · cited 1×
“Analogous to the ultrasonic Doppler effect, the PA Doppler (PAD) effect was observed and utilized in axial speed measurement (87; 88).”
MethodSelf-citationBrunker, J., & Beard, P. (2012) · The Journal of the Acoustical Society of America · doi:10.1121/1.4739458 · Cited by 64 · cited 2×
“For these reasons, the PA flowmetry is particularly advantageous in the measurement of low blood flow velocities in the microvasculature (89).”
BackgroundPhotoacoustic correlation spectroscopy and its application to low-speed flow measurement
Chen, S., Ling, T., Huang, S.-W., Baac, H. W., & Guo, L. J. (2010) · Optics Letters · doi:10.1364/ol.35.001200 · Cited by 62 · cited 1×
“For extremely slow-flow measurement, photoacoustic correlation spectroscopy (PACS) was exploited owing to its high detection sensitivity (95, 96).”
MethodChristopher, D. A., Burns, P. N., Armstrong, J., & Foster, F. S. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00153-6 · Cited by 58 · cited 1×
“Compared to ultrasonic flowmetry (86), PA flowmetry has an advantage in low flow speed (<1 mm/s) measurement.”
BackgroundWang, X., Chamberland, D. L., & Xi, G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.11.007 · Cited by 56 · cited 1×
“Although PAT of the brain through a skull was well conducted on monkeys (120; 121) and an infant (122), not until very recently, were the feasibility of imaging through adult skulls demonstrated (115).”
BackgroundLifetime-based photoacoustic oxygen sensing in vivo
Ray, A., Kopelman, R., Rajian, J. R., Wang, X., & Lee, Y.-E. K. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.057004 · Cited by 45 · cited 1×
“Additionally, fluence-independent quantities, including acoustic spectra (77; 78) and molecular lifetime (79), have been used to recover blood sO2.”
MethodPhotoacoustic Spectroscopy: New Uses for an Old Technique
Maugh, T. H. (1975) · Science · doi:10.1126/science.188.4183.38 · Cited by 44 · cited 1×
“In biomedicine, the application of the PA effect started in the 1970s (4); however, not until the last decade of the 20th century were breakthroughs achieved in demonstrating the PA effect in optically scattering media and biological tissue (5; 6).”
BackgroundIntracellular temperature mapping with fluorescence-assisted photoacoustic-thermometry
Gao, L. S., Zhang, C., Li, C., & Wang, L. V. (2013) · Applied Physics Letters · doi:10.1063/1.4807140 · Cited by 39
Self-citationHybrid photoacoustic and ultrasound section imaging with optical ultrasound detection
Nuster, R., Schmitner, N., Wurzinger, G., Gratt, S., Salvenmoser, W., Meyer, D., & Paltauf, G. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201200223 · Cited by 34
Three-dimensional Optical-resolution Photoacoustic Microscopy
Hu, S., Maslov, K., & Wang, L. V. (2011) · Journal of Visualized Experiments · doi:10.3791/2729 · Cited by 28 · cited 1×
“For a focused ultrasonic transducer with a aperture of diameter D, and focal length l, the lateral resolution is computed as (42)”
MethodSelf-citationAngle-insensitive flow measurement using Doppler bandwidth
Yeung, K.-W. W. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.677602 · Cited by 16 · cited 1×
“PA flowmetry is superior to other Doppler-effect-based methods, such as functional optical coherent tomography (OCT) (91) or Doppler ultrasonography (92), in blood flow measurement because PA provides unique 100% optical absorption contrast (8), whereas purely optical or ultrasonic approaches depend on optical or ultr…”
MethodCompensation of Ultrasound Attenuation in Photoacoustic Imaging
Burgholzer, P., Roitner, H., Bauer-Marschallinger, J., Grün, H., Berer, T., & Paltauf, G. (2011) · InTech eBooks · doi:10.5772/19815 · Cited by 12 · cited 1×
“To improve image quality, the ultrasonic attenuation can be accounted for mathematically (18; 19).”
BackgroundGao, L. S., Hagen, N. A., & Tkaczyk, T. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03596.x · Cited by 10 · cited 1×
“The accuracy of recovered sO2 relies on the SNR of each spectral channel and the condition number of the spectral component matrix (71).”
BackgroundSelf-citation
Cited by
Tutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Self-citationPrecise nanomedicine for intelligent therapy of cancer
Chen, H., Gu, Z., An, H., Chen, C., Chen, J., Cui, R., Chen, S., Chen, W., Chen, X., Chen, X., et al. (2018) · Science China Chemistry · doi:10.1007/s11426-018-9397-5 · Cited by 409
Ultrasensitive plano-concave optical microresonators for ultrasound sensing
Guggenheim, J. A., Li, J., Allen, T. J., Colchester, R. J., Noimark, S., Ogunlade, O., Parkin, I. P., Papakonstantinou, I., Desjardins, A. E., Zhang, E. Z., et al. (2017) · Nature Photonics · doi:10.1038/s41566-017-0027-x · Cited by 391
Photoacoustic Imaging-Trackable Magnetic Microswimmers for Pathogenic Bacterial Infection Treatment
Xie, L., Pang, X., Yan, X., Dai, Q., Lin, H., Ye, J., Cheng, Y., Zhao, Q., Ma, X., Zhang, X., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b06731 · Cited by 261
Deep learning for biomedical photoacoustic imaging: A review
Gröhl, J., Schellenberg, M., Dreher, K., & Maier-Hein, L. (2021) · Photoacoustics · doi:10.1016/j.pacs.2021.100241 · Cited by 248
“Photoacoustic imaging (PAI) is a comparatively young and rapidly emerging imaging modality that promises real-time, noninvasive, and radiation-free measurement of optical tissue properties [1].”
Background
Metadata
- Authors
- Wang, L. V., & Gao, L.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2014-07-11
- Volume
- 16
- Issue
- 1
- Pages
- 155-185
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2100562442
- Cited by
- 246
- References
- 88
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.