Fluid Mechanics of Vascular Systems, Diseases, and Thrombosis
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
▪ Abstract The cardiovascular system is an internal flow loop with multiple branches circulating a complex liquid. The hallmarks of blood flow in arteries are pulsatility and branches, which cause wall stresses to be cyclical and nonuniform. Normal arterial flow is laminar, with secondary flows generated at curves and branches. Arteries can adapt to and modify hemodynamic conditions, and unusual hemodynamic conditions may cause an abnormal biological response. Velocity profile skewing can create pockets in which the wall shear stress is low and oscillates in direction. Atherosclerosis tends to localize to these sites and creates a narrowing of the artery lumen—a stenosis. Plaque rupture or endothelial injury can stimulate thrombosis, which can block blood flow to heart or brain tissues, causing a heart attack or stroke. The small lumen and elevated shear rate in a stenosis create conditions that accelerate platelet accumulation and occlusion. The relationship between thrombosis and fluid mechanics is complex, especially in the post-stenotic flow field. New convection models have been developed to predict clinical occlusion from platelet thrombosis in diseased arteries. Future hemodynamic studies should address the complex mechanics of flow-induced, large-scale wall motion and convection of semisolid particles and cells in flowing blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid Stenosis
(1991) · New England Journal of Medicine · doi:10.1056/nejm199108153250701 · Cited by 8,368
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
Self-citationFinal Report on the Aspirin Component of the Ongoing Physicians' Health Study
Steering Committee of the Physicians' Health Study Research Group* (1989) · New England Journal of Medicine · doi:10.1056/nejm198907203210301 · Cited by 2,264
Davies, M. J., & Thomas, A. C. (1985) · Heart · doi:10.1136/hrt.53.4.363 · Cited by 1,985
Thrombosis and Acute Coronary-Artery Lesions in Sudden Cardiac Ischemic Death
Davies, M. J., & Thomas, A. (1984) · New England Journal of Medicine · doi:10.1056/nejm198405033101801 · Cited by 1,694
WALKER, M. D., Marler, J. R., Goldstein, M., Grady, P. A., Toole, J. F., Baker, W. H., Castaldo, J., Chambless, L. E., Moore, W. S., Robertson, J. T., et al. (1995) · JAMA · doi:10.1001/jama.273.18.1421 · Cited by 1,334
Localization of tissue factor in the normal vessel wall and in the atherosclerotic plaque.
Wilcox, J. N., Smith, K. M., Schwartz, S. M., & Gordon, D. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.8.2839 · Cited by 1,214
Initiation of Platelet Adhesion by Arrest onto Fibrinogen or Translocation on von Willebrand Factor
Savage, B., Saldívar, E., & Ruggeri, Z. M. (1996) · Cell · doi:10.1016/s0092-8674(00)80983-6 · Cited by 1,196
Langille, B. L., & O'Donnell, F. (1986) · Science · doi:10.1126/science.3941904 · Cited by 1,113
Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries.
Glagov, S., Zarins, C. K., Giddens, D. P., & Ku, D. N. (1988) · PubMed · Cited by 1,029
Self-citation
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“There is increasing evidence that various hemodynamic forces, including fluid shear stress, can also influence the structure and function of ECs and modulate their expressions of pathophysiologically relevant genes (74, 87, 93, 125, 131, 153, 203, 211, 213, 230, 240, 279, 282, 337, 571, 625).”
BackgroundCell and molecular mechanics of biological materials
Bao, G., & Suresh, S. (2003) · Nature Materials · doi:10.1038/nmat1001 · Cited by 1,055
Arterial thrombosis—insidious, unpredictable and deadly
Jackson, S. P. (2011) · Nature Medicine · doi:10.1038/nm.2515 · Cited by 685
Using shape effects to target antibody-coated nanoparticles to lung and brain endothelium
Kolhar, P., Anselmo, A. C., Gupta, V., Pant, K., Prabhakarpandian, B., Ruoslahti, E., & Mitragotri, S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1308345110 · Cited by 646
Pyke, K. E., & Tschakovsky, M. E. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.089755 · Cited by 614
Shear-Activated Nanotherapeutics for Drug Targeting to Obstructed Blood Vessels
Korin, N., Kanapathipillai, M., Matthews, B. D., Crescente, M., Brill, A., Mammoto, T., Ghosh, K., Jurek, S., Bencherif, S. A., Bhatta, D., et al. (2012) · Science · doi:10.1126/science.1217815 · Cited by 540
Flow Effects on Coagulation and Thrombosis
Hathcock, J. J. (2006) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000229658.76797.30 · Cited by 387
Bazilevs, Y., Gohean, J. R., Hughes, T. J. R., Moser, R. D., & Zhang, Y. (2009) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.04.015 · Cited by 386
Mechanical Force-Triggered Drug Delivery
Zhang, Y., Yu, J., Bomba, H. N., Zhu, Y., & Gu, Z. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00369 · Cited by 354
Jain, A., Barrile, R., van der Meer, A., Mammoto, A., Mammoto, T., De Ceunynck, K., Aisiku, O., Otieno, M., Louden, C., Hamilton, G., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.742 · Cited by 325
Procoagulant Activity in Hemostasis and Thrombosis: Virchow's Triad Revisited
Wolberg, A. S., Aleman, M. M., Leiderman, K., & Machlus, K. R. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31823a088c · Cited by 312
Intracranial aneurysms: links among inflammation, hemodynamics and vascular remodeling
Hashimoto, T., Meng, H., & Young, W. L. (2006) · Neurological Research · doi:10.1179/016164106x14973 · Cited by 266
Flow Shear Stress and Atherosclerosis: A Matter of Site Specificity
Nigro, P., Abe, J.-I., & Berk, B. C. (2011) · Antioxidants & Redox Signaling · doi:10.1089/ars.2010.3679 · Cited by 263
Three-dimensional instabilities and transition of steady and pulsatile axisymmetric stenotic flows
SHERWIN, S. J., & BLACKBURN, H. M. (2005) · Journal of Fluid Mechanics · doi:10.1017/s0022112005004271 · Cited by 220
“For discussion of these assumptions and reviews of recent work on blood flow in arteries, see Ku (1997), Wootton & Ku (1999), Berger & Jou (2000) and Taylor & Draney (2004).”
BackgroundInfluentialAntiplatelet therapy: in search of the 'magic bullet'
Jackson, S. P., & Schoenwaelder, S. M. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1198 · Cited by 193
“Platelets are exposed to high-shear forces and a range of abnormal flow patterns during the atherothrombotic process, including flow separation, eddy formation, flow reversal and turbulence, which produce complex, rapid changes in the shear environmen”
BackgroundEngineered Microsystems for Spheroid and Organoid Studies
Kang, S., Kim, D., Lee, J., Takayama, S., & Park, J. Y. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001284 · Cited by 100
Cito, S., Geers, A. J., Arroyo, M. P., Palero, V. R., Pallarés, J., Vernet, A., Blasco, J., San Román, L., Fu, W., Qiao, A., et al. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1082-9 · Cited by 20
Metadata
- Authors
- Wootton, D. M., & Ku, D. N.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 1999-08
- Volume
- 1
- Issue
- 1
- Pages
- 299-329
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2134785906
- Cited by
- 559
- References
- 56
- FWCI
- 0.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.