The DOI matches its Crossref record; 217 of the 217 references it cites were found in a registry or an index.
Point-of-Care Diagnostics for Global Health
Abstract
Biomedical engineers have traditionally developed technologies in response to the needs of the developed world's medical community. As a result, the diagnostic systems on which they have worked have met the requirements of well-funded laboratories in highly regulated and quality-assessed environments. However, such approaches do not address the needs of the majority of the world's people afflicted with infectious diseases, who have, at best, access to poorly resourced health care facilities with almost no supporting clinical laboratory infrastructure. A major challenge for the biomedical engineering community is to develop diagnostic tests to meet the needs of these people, the majority of whom are in the developing world. We here review the context in which the diagnostics must operate, some of the appropriate diagnostic technologies already in distribution, and some emerging technologies that promise to address this challenge. However, there is much room for innovation, adaptation, and cost reduction before these technologies can impact health care in the developing world.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The governments of India, Nepal, and Bangladesh pledged to eliminate visceral leishmaniasis by 2015, which along with improved treatment access, prompted the development of a simple point-of-care diagnostic tool which detects antibody agglutination”
From Global Burden of Skin Disease: Inequities and Innovations (2017) · cites this paper as [45]
Citations
Cites
Projections of Global Mortality and Burden of Disease from 2002 to 2030
Mathers, C. D., & Loncar, D. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030442 · Cited by 11,386
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Quantum Dot Bioconjugates for Ultrasensitive Nonisotopic Detection
Chan, W. C. W., & Nie, S. (1998) · Science · doi:10.1126/science.281.5385.2016 · Cited by 7,284
(1996) · Cited by 6,884
The Growing Burden of Tuberculosis: Global Trends and Interactions With the HIV Epidemic
Corbett, E. L., Watt, C. J., Walker, N., Maher, D., Williams, B. G., Raviglione, M. C., & Dye, C. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.9.1009 · Cited by 2,553
How many child deaths can we prevent this year?
Jones, G., Steketee, R. W., Black, R. E., Bhutta, Z. A., & Morris, S. S. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13811-1 · Cited by 2,244
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,224
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T. L., Fu, E. S., Helton, K. L., Nelson, K. E., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,982
Self-citationGold nanostructures: engineering their plasmonic properties for biomedical applications
Hu, M., Chen, J., Li, Z., Au, L., Hartland, G. V., Li, X. D., Márquez, M., & Younan Xia, A. (2006) · Chemical Society Reviews · doi:10.1039/b517615h · Cited by 1,758
How many child deaths can we prevent this year?
(2003) · Child Care Health and Development · doi:10.1046/j.1365-2214.2003.00376_6.x · Cited by 1,585
Research works printed but not linked: 26
- Kong H, 2007, In Vivo Diagn. Technol., 35
- Herzlinger RE, 2003, Healthplan, 44, 26
- Edington D, 2004, Health Prod. Manag., 3, 12
- Constantine NT, 2005, Indian J. Med. Res., 121, 519
- Majchrowicz M, 2003, AIDS, 17, S13
- Zar HJ, 2005, South Afr. Med. J., 95, 977
- Gerbase AC, 1998, Sex. Transm. Infect., 74, S12
- Schmid G, 2004, Bull. World Health Organ., 82, 402
- 10.1097/00042560-200005010-00009 · DOI
- World Health Organ, 2001, Global database on blood safety: summary report 1998–1999
- Opare-Sem O, 2002, Afr. Sang., 5, 12
- Johnson R, 2006, Curr. Issues Mol. Biol., 8, 97
- Harries AD, 2004, Int. J. Tuberc. Lung Dis., 8, 204
- Boelaert M, 1999, Bull. World Health Organ., 77, 667
- Shillcutt SD, 2007, World Health Organ. Rep.
- Baik F, 2007, World Health Organ. Rep.
- Chan CP, 2008, Adv. Biochem. Eng. Biotechnol., 109, 123
- World Health Organ, 2007, Guildelines on Standard Operating Procedures for Microbology
- Yager P, 1998, U.S. Patent No. 5726751
- 160. Hatch AV. 2004. Diffusion based analysis of molecular binding reactions in microfluidic devices. PhD thesis. Univ. Washington, Seattle. 224pp.
- 10.1002/1522-2683(200203)23:5<740::AID-ELPS740>3.0.CO;2-7 · DOI
- Nelson K, 2006, Proc. Anniv. Int. Conf. Miniat. Syst. Chem. Life Sci., 10th, Tokyo, 825
- Gao X, 2005, Methods Mol. Biol., 303, 61
- Fu E, 2007, Ann. N.Y. Acad. Sci., 1098
- 10.1016/j.snb.2006.09.059 · DOI
- Fu E, 2008, Rev. Sci. Instrum.
Cited by
Sorted by citations
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Point-of-care tests for diagnosing infections in the developing world
Peeling, R. W., & Mabey, D. (2010) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2010.03279.x · Cited by 500
Global Burden of Skin Disease: Inequities and Innovations
Seth, D., Cheldize, K., Brown, D., & Freeman, E. E. (2017) · Current Dermatology Reports · doi:10.1007/s13671-017-0192-7 · Cited by 366
Recent advances in cortisol sensing technologies for point-of-care application
Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.060 · Cited by 316
ZnO Nanorod Integrated Flexible Carbon Fibers for Sweat Cortisol Detection
Madhu, S., Anthuuvan, A. J., Ramasamy, S., Manickam, P., Bhansali, S., Nagamony, P., & Chinnuswamy, V. (2020) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.9b00730 · Cited by 102
Metadata
- Authors
- Yager, P., Domingo, G. J., & Gerdes, J.
- Affiliations
- University of Washington (US)
- Program for Appropriate Technology in Health (US)
- Redmond Fire Department (US)
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2008-08-01
- Volume
- 10
- Issue
- 1
- Pages
- 107-144
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2170895924
- Cited by
- 1,076
- References
- 217
- Citations by year
- 2026: 34 · 2025: 43 · 2024: 47 · 2023: 58 · 2022: 55 · 2021: 55 · 2020: 89 · 2019: 56 · 2018: 65 · 2017: 73 · 2016: 72 · 2015: 87 · 2014: 79 · 2013: 78 · 2012: 51
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Social Sciences › Business, Management and Accounting › Business and International Management › Innovation and Socioeconomic Development
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Keywords
- point-of-care testing, global health, resource-limited settings, infectious diseases, diagnostic technology development, cost reduction, emerging diagnostic technologies
- MeSH terms
- Monitoring, Physiologic, Technology Assessment, Biomedical, Global Health, Point-of-Care Systems, Diagnostic Techniques and Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review