Computational Anthropomorphic Models of the Human Anatomy: The Path to Realistic Monte Carlo Modeling in Radiological Sciences
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
The widespread availability of high-performance computing and popularity of simulations stimulated the development of computational anthropomorphic models of the human anatomy for medical imaging modalities and dosimetry calculations. The widespread interest in molecular imaging spurred the development of more realistic three- to five-dimensional computational models based on the actual anatomy and physiology of individual humans and small animals. These can be defined by either mathematical (analytical) functions or digital (voxel-based) volume arrays (or a combination of both), thus allowing the simulation of medical imaging data that are ever closer to actual patient data. The paradigm shift away from the stylized human models is imminent with the development of more than 30 voxel-based tomographic models in recent years based on anatomical medical images. We review the fundamental and technical challenges of designing computational models of the human anatomy, and focus particularly on the latest developments and future directions of their application in the simulation of radiological imaging systems and dosimetry calculations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piegl, L., & Tiller, W. (1997) · Monographs in Visual Communication · doi:10.1007/978-3-642-59223-2 · Cited by 2,871
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774 · cited 1×
“(67) from the National Institute of Information and Communications Technology (NIICT) reported an adult male model, named Nagaoka Man, and an adult female model, named Nagaoka Woman, developed from magnetic resonance images for radio-frequency electromagnetic-field dosimetry.”
MethodSpecific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Ws, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
MIRD primer for absorbed dose calculations
LOEVINGER, R., Budinger, T. F., & Watson, E. E. (1988) · Medical Entomology and Zoology · Cited by 552
Development of a 4-D digital mouse phantom for molecular imaging research
SEGARS, W. (2004) · Molecular Imaging & Biology · doi:10.1016/j.mibio.2004.03.002 · Cited by 420 · cited 2×
“Most previously reported small-animal models have been stylized and mathematically based (45).”
BackgroundMethodXu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
Self-citation
Cited by
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
Bolch, W. E., Eckerman, K. F., Sgouros, G., & Thomas, S. R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056036 · Cited by 913
Xu, X. G., Bednarz, B., & Paganetti, H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/13/r01 · Cited by 415
Self-citationZaidi, H., & El Naqa, I. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1423-3 · Cited by 366
Self-citationThe UF family of reference hybrid phantoms for computational radiation dosimetry
Lee, C., Lodwick, D., Hurtado, J., Pafundi, D., Williams, J. L., & Bolch, W. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/002 · Cited by 345
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
Self-citationHatt, M., Lee, J. A., Schmidtlein, C. R., Naqa, I. E., Caldwell, C., De Bernardi, E., Lu, W., Das, S., Geets, X., Gregoire, V., et al. (2017) · Medical Physics · doi:10.1002/mp.12124 · Cited by 198
“Virtual or numerical phantoms associated with a PET image generation process represent an inexpensive, precise way to test PET software and clinical methodologies.(163) One definition of a virtual or numerical PET simulation framework corresponds to any computer-generated object that is processed to produce a PET-like…”
MethodSelf-citationLee, C., Kim, K. P., Bolch, W. E., Moroz, B. E., & Folio, L. (2015) · Journal of Radiological Protection · doi:10.1088/0952-4746/35/4/891 · Cited by 197
Xu, X. G., Taranenko, V., Zhang, J., & Shi, C. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/23/017 · Cited by 197
Self-citationAssessing Human Exposure to Electromagnetic Fields From Wireless Power Transmission Systems
Christ, A., Douglas, M., Nadakuduti, J., & Kuster, N. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2245851 · Cited by 173
Assessment of Human Exposure to Electromagnetic Fields: Review and Future Directions
Hirata, A., Diao, Y., Onishi, T., Sasaki, K., Ahn, S., Colombi, D., De Santis, V., Laakso, I., Giaccone, L., Wout, J., et al. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3109249 · Cited by 161
“With a long history starting with simple geometric representations [6], human models have reached an advanced quality representing human anatomy with superior accuracy (e.g., [7]).”
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
“A more comprehensive list can be found in the review papers by Xu [6], Zaidi and Xu [82], and Zaidi and Tsui [83].”
Self-citation
Metadata
- Authors
- Zaidi, H., & Xu, X. G.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2007-08-15
- Volume
- 9
- Issue
- 1
- Pages
- 471-500
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2099608879
- Cited by
- 219
- References
- 48
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.