The widespread availability of high-performance computing and popularity of simulations stimulated the development of computational anthropomorphic models of the human anatomy for medical imaging modalities and dosimetry calculations. The widespread interest in molecular imaging spurred the development of more realistic three- to five-dimensional computational models based on the actual anatomy and physiology of individual humans and small animals. These can be defined by either mathematical (analytical) functions or digital (voxel-based) volume arrays (or a combination of both), thus allowing the simulation of medical imaging data that are ever closer to actual patient data. The paradigm shift away from the stylized human models is imminent with the development of more than 30 voxel-based tomographic models in recent years based on anatomical medical images. We review the fundamental and technical challenges of designing computational models of the human anatomy, and focus particularly on the latest developments and future directions of their application in the simulation of radiological imaging systems and dosimetry calculations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piegl, L., & Tiller, W. (1997) · Monographs in Visual Communication · doi:10.1007/978-3-642-59223-2 · Cited by 2,871
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774 · cited 1×
“(67) from the National Institute of Information and Communications Technology (NIICT) reported an adult male model, named Nagaoka Man, and an adult female model, named Nagaoka Woman, developed from magnetic resonance images for radio-frequency electromagnetic-field dosimetry.”
MethodSpecific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Ws, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
MIRD primer for absorbed dose calculations
LOEVINGER, R., Budinger, T. F., & Watson, E. E. (1988) · Medical Entomology and Zoology · Cited by 552
Development of a 4-D digital mouse phantom for molecular imaging research
SEGARS, W. (2004) · Molecular Imaging & Biology · doi:10.1016/j.mibio.2004.03.002 · Cited by 420 · cited 2×
“Most previously reported small-animal models have been stylized and mathematically based (45).”
BackgroundMethodXu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
Self-citation3-D phantom to simulate cerebral blood flow and metabolic images for PET
Hoffman, E. J., Cutler, P. D., Digby, W. M., & Mazziotta, J. C. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106686 · Cited by 353 · cited 1×
“A clinically realistic brain model simulating source distributions in the human brain—typical in cerebral blood flow and metabolism studies employed in PET, providing apparent relative concentrations of 4, 1, and 0 for gray matter, white matter, and ventricles, respectively, in functional brain imaging—was developed (…”
MethodIn vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Dimbylow, P. J. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/3/003 · Cited by 284 · cited 7×
“Reference arms mathematically straightened along the model's side (54) NRPB, UK NORMAN MRI Caucasian Adult male Only 10 ribs (57, 59) NRPB, UK NAOMI MRI Caucasian Adult female Healthy volunteer (60) ENEA-ION Istituto di Radioprotezione, Italy NORMAN-05 MRI Caucasian Adult male Adjusted to ICRP 2005 (80) RPI, USA Pregn…”
MethodResultInfluentialThe GSF family of voxel phantoms
Petoussi-Henss, N., Zankl, M., Fill, U., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/307 · Cited by 280 · cited 1×
“(61, 62) from the National Research Center for Environment and Health (GSF), Germany, developed a family of nine tomographic models, all from CT images: BABY, CHILD, DONNA, FRANK, GOLEM, HELGA, IRENE, LAURA, and VISIBLE MAN.”
Relevance of accurate Monte Carlo modeling in nuclear medical imaging
Zaidi, H. (1999) · Medical Physics · doi:10.1118/1.598559 · Cited by 279 · cited 3×
“Such computational models are used extensively to derive many of the existing conversion parameters in radiation protection and nuclear medicine dosimetry, and to develop new image-reconstruction and processing algorithms in biomedical imaging (1).”
BackgroundMethodSelf-citationDimbylow, P. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/002 · Cited by 276 · cited 1×
“Dimbylow later developed an adult female model, NAOMI, from 2-mm-pixel MRI scans (60).”
MethodThe visible human dataset: The anatomical platform for human simulation
Spitzer, V. M., & Whitlock, D. (1998) · The Anatomical Record · doi:10.1002/(sici)1097-0185(199804)253:2<49::aid-ar8>3.0.co;2-9 · Cited by 275 · cited 3×
“7 billion voxels, and the original images were segmented to yield more than 1400 organs and tissues, although only approximately 80 were adopted for radiation dosimetry applications (47, 72).”
BackgroundInfluentialDevelopment and application of the new dynamic Nurbs-based Cardiac-Torso (NCAT) phantom.
Segars, W. P., Tsui, B. M. W., Lalush, D. S., Frey, E. C., King, M., & Manocha, D. (2001) · ScholarWorks@UMassAmherst (University of Massachusetts Amherst) · Cited by 254
Kramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/301 · Cited by 239 · cited 1×
“(55) from Brazil recently developed a male adult voxel model named MAX (Male Adult voXel) for Monte Carlo calculations and a female adult model named FAX (56).”
BackgroundScatter modelling and compensation in emission tomography
Zaidi, H., & Koral, K. F. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1495-z · Cited by 214 · cited 1×
“A recent review by Zaidi & Koral (91) extensively describes modeling the scatter-response function and development and assessment of scatter-correction methods in both SPECT and PET using Monte Carlo simulations.”
MethodSelf-citationVoxel-based computational models of real human anatomy: a review
Caon, M. (2004) · Radiation and Environmental Biophysics · doi:10.1007/s00411-003-0221-8 · Cited by 213 · cited 1×
“Table 1 is an updated version of that from a recent review paper (49).”
BackgroundThe adult male voxel model ”Golem" segmented from whole-body CT patient data
Zankl, M., & Wittmann, A. (2001) · Radiation and Environmental Biophysics · doi:10.1007/s004110100094 · Cited by 207
Stabin, M. G., Watson, E. E., Cristy, M., Ryman, J. C., Eckerman, K. F., Davis, J. L., Marshall, D., & Gehlen, M. K. (1995) · doi:10.2172/91944 · Cited by 194 · cited 1×
“(17) released a set of models representing the adult female at different stages of gestation, to satisfy the need to calculate radiation doses to the fetus for nuclear medicine and other applications.”
BackgroundFine resolution calculations of SAR in the human body for frequencies up to 3 GHz
Dimbylow, P. J. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/16/301 · Cited by 179 · cited 1×
“Dimbylow (57, 58) from the National Radiological Protection Board (NRPB), United Kingdom, developed an adult male model known as NORMAN using magnetic resonance images of 2 mm × 2 mm resolution and 10-mm-thick slices.”
MethodZankl, M., Veit, R., Williams, G., Schneider, K., Fendel, H., Petoussi, N., & Drexler, G. (1988) · Radiation and Environmental Biophysics · doi:10.1007/bf01214605 · Cited by 172 · cited 1×
“The BABY and CHILD models were one of the first nonadult models (63).”
MethodBouchet, L. G., Bolch, W. E., Blanco, H. P., Wessels, B. W., Siegel, J. A., Rajon, D. A., Clairand, I., & Sgouros, G. (2003) · PubMed · Cited by 165
Organ dose conversion coefficients for external photon irradiation of male and female voxel models
Zankl, M., Fill, U., Petoussi-Henss, N., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/14/301 · Cited by 162 · cited 5×
“Zankl et al. (61, 62) from the National Research Center for Environment and Health (GSF), Germany, developed a family of nine tomographic models, all from CT images: BABY, CHILD, DONNA, FRANK, GOLEM, HELGA, IRENE, LAURA, and VISIBLE MAN.”
MethodInfluentialZhang, S., Heng, P., Liu, Z., Tan, L., Qiu, M., Li, Q., Liao, R., Li, K., Cui, G., Guo, Y., et al. (2004) · Journal of Anatomy · doi:10.1111/j.0021-8782.2004.00274.x · Cited by 154 · cited 2×
“Other countries, including India and China (48), are reportedly also developing their own tomographic models.”
BackgroundFrouin, V., Comtat, C., Reilhac, A., & Grégoire, M. (2002) · PubMed · Cited by 149
Kramer, R., Khoury, H. J., Vieira, J. W., Loureiro, E. C. M., Lima, V. J. M., Lima, F. R. A., & Hoff, G. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/001 · Cited by 131 · cited 3×
“Kramer et al. (79) introduced the MAX06 and FAX06, which are based on the MAX and FAX models, respectively.”
BackgroundThe modelling of positron emitter production and PET imaging during carbon ion therapy
Pönisch, F., Parodi, K., Hasch, B. G., & Enghardt, W. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/002 · Cited by 130 · cited 1×
“There has been an enormous increase and interest in the use of Monte Carlo techniques in all aspects of radiological sciences, covering almost all topics including detector modeling and imaging systems design, development and evaluation of image-correction and reconstruction techniques, and internal dosimetry and phar…”
BackgroundMAX06 and FAX06: update of two adult human phantoms for radiation protection dosimetry
Kramer, R. A., Khoury, H. J., Vieira, J. W., & Lima, V. J. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/003 · Cited by 129 · cited 1×
“(79) introduced the MAX06 and FAX06, which are based on the MAX and FAX models, respectively.”
MethodCaon, M., Bibbo, G., & Pattison, J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/9/309 · Cited by 123 · cited 1×
“(64) from Flinders University, Australia, reported a partial-body model named ADELAIDE, which represents a 14year-old girl.”
BackgroundFill, U. A., Zankl, M., Petoussi-Henss, N., Siebert, M., & Regulla, D. F. (2004) · Health Physics · doi:10.1097/00004032-200403000-00003 · Cited by 111 · cited 1×
“(61, 62) from the National Research Center for Environment and Health (GSF), Germany, developed a family of nine tomographic models, all from CT images: BABY, CHILD, DONNA, FRANK, GOLEM, HELGA, IRENE, LAURA, and VISIBLE MAN.”
The UF series of tomographic computational phantoms of pediatric patients
Lee, C., Williams, J. L., Lee, C., & Bolch, W. E. (2005) · Medical Physics · doi:10.1118/1.2107067 · Cited by 110 · cited 1×
“Recently, Bolch and colleagues (65, 66) from the University of Florida created a series of pediatric models ranging from the first year of life to 14 years old.”
BackgroundJones, D. G. (1997) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032072 · Cited by 105 · cited 1×
“His colleague from NRPB, Jones (59), adopted NORMAN to estimate organ doses from external and internal photon sources.”
BackgroundFully 3D Monte Carlo reconstruction in SPECT: a feasibility study
Lazaro, D., Bitar, Z. E., Breton, V., Hill, D. R. C., & Buvat, I. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/16/006 · Cited by 96 · cited 1×
“approaches spurred the development of computationally efficient algorithms capable of obtaining highly accurate quantitative data in clinically acceptable computation times (89).”
BackgroundNoise characterization of block-iterative reconstruction algorithms. I. Theory
Soares, E. J., Byrne, C. L., & Glick, S. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.848178 · Cited by 87
Japanese adult male voxel phantom constructed on the basis of CT images
Sato, K., Noguchi, H., Emoto, Y., Koga, S., & Saitô, K. (2006) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncl101 · Cited by 86
Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT
Ay, M. R., & Zaidi, H. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/20/009 · Cited by 78 · cited 1×
“Another example is the X-ray CT Monte Carlo simulator based on the MCNP4C radiation transport computer code developed for simulation of fan- and cone-beam CT scanners (100).”
MethodSelf-citationTherapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
Ewell, L. (2003) · Medical Physics · doi:10.1118/1.1603742 · Cited by 77
Ay, M. R., & Zaidi, H. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0086-6 · Cited by 62 · cited 1×
“The simulator was validated using experimental measurements from different phantoms containing steel, Teflon, water, polyethylene, and air cylinders, with different sizes on a clinical fan-beam scanner and a small-animal cone-beam CT scanner, and is now being used extensively for development and assessment of sources…”
MethodSelf-citationConsiderations of marrow cellularity in 3-dimensional dosimetric models of the trabecular skeleton.
Bolch, W. E., Patton, P. W., Rajon, D. A., Shah, A. P., Jokisch, D. W., & Inglis, B. A. (2002) · PubMed · Cited by 54
Korean adult male voxel model KORMAN segmented from magnetic resonance images
Lee, C., Lee, J., & Lee, C. (2004) · Medical Physics · doi:10.1118/1.1689013 · Cited by 49
Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification
Dewaraja, Y. K., Ljungberg, M. H., & Koral, K. F. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590100551 · Cited by 40 · cited 1×
“Monte Carlo simulations are also powerful tools to investigate the limits of algorithms developed for correction of partial-volume effect by allowing the replication of realistic conditions in emission tomography for a wide range of practical situations, and to study the effect of object shape and size on recovery per…”
BackgroundZaidi, H., Labbé, C., & Morel, C. (1998) · Parallel Computing · doi:10.1016/s0167-8191(98)00069-6 · Cited by 38 · cited 1×
“An implementation of the software on a high-performance parallel platform was also reported (99).”
MethodSelf-citationZaidi, H., Montandon, M., & Slosman, D. O. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1325-8 · Cited by 36 · cited 1×
“The same head/brain model used in the latter was employed for deriving a patient-specific attenuation map by registering the brain component of the digital-head atlas (52) with a source distribution of 4:1:0 for gray matter, white matter, and ventricles, respectively, to a preliminary PET reconstruction and then apply…”
MethodSelf-citationPeter, J., Gilland, D. R., Jaszczak, R. J., & Coleman, R. E. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.819306 · Cited by 31 · cited 1×
“This is made possible through the development of appropriate primitives that allow the accurate modeling of anatomical variations and patient motion, such as superquadrics (39) and nonuniform rational B-spline surfaces (NURBS) (40, 41).”
Cited by
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
Bolch, W. E., Eckerman, K. F., Sgouros, G., & Thomas, S. R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056036 · Cited by 913
Xu, X. G., Bednarz, B., & Paganetti, H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/13/r01 · Cited by 415
Self-citationZaidi, H., & El Naqa, I. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1423-3 · Cited by 366
Self-citationThe UF family of reference hybrid phantoms for computational radiation dosimetry
Lee, C., Lodwick, D., Hurtado, J., Pafundi, D., Williams, J. L., & Bolch, W. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/002 · Cited by 345
Metadata
- Authors
- Zaidi, H., & Xu, X. G.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2007-08-15
- Volume
- 9
- Issue
- 1
- Pages
- 471-500
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2099608879
- Cited by
- 219
- References
- 48
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.