Fluid and Solute Transport in Bone: Flow-Induced Mechanotransduction
Open accessThe DOI matches its Crossref record; 130 of the 130 references it cites were found in a registry or an index.
Abstract
Much recent evidence suggests that bone cells sense their mechanical environment via interstitial fluid flow. In this review, we summarize theoretical and experimental approaches to quantify fluid and solute transport in bone, starting with the early investigations of fluid shear stress applied to bone cells. The pathways of bone interstitial fluid and solute movement are highlighted based on recent theoretical models, as well as a new generation of tracer experiments that have clarified and refined the structure and function of the osteocyte pericellular matrix. Then we trace how the fluid-flow models for mechanotransduction have evolved as new ultrastructural features of the osteocyte lacunar-canalicular porosity have been identified and how more recent in vitro fluid-flow and cell-stretch experiments have helped elucidate at the molecular level the possible pathways for cellular excitation in bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2001) · CRC Press eBooks · doi:10.1201/b14263 · Cited by 1,451
Mechanical Stimulation of Bone in Vivo Reduces Osteocyte Expression of Sost/Sclerostin
Robling, A. G., Niziolek, P. J., Baldridge, L. A., Condon, K. W., Allen, M. R., Alam, I., Mantila, S. M., Gluhak-Heinrich, J., Bellido, T. M., Harris, S. E., et al. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m705092200 · Cited by 1,350 · cited 1×
“…respond to mechanical loading in vivo (e.g., Dodd et al. 1999, Dodds et al. 1993, Forwood et al. 1998, Gluhak-Heinrich et al. 2003, Lean et al. 1995, Pead et al. 1988, Robling et al. 2008, Rubin et al. 1999, Skerry et al. www.annualreviews.org • Fluid and Solute Transport in Bone 365 A nn u.”
BackgroundRegulation of bone mass by mechanical strain magnitude
Rubin, C. T., & Lanyon, L. E. (1985) · Calcified Tissue International · doi:10.1007/bf02553711 · Cited by 1,294
A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses
Weinbaum, S., Cowin, S. C., & Zeng, Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90010-8 · Cited by 1,277
Self-citationSensitivity of osteocytes to biomechanical stress in vitro
Klein‐Nulend, J., Van Der Plas, A., Semeins, C. M., Ajubi, N. E., Erangos, J. A., Nijweide, P. J., & Burger, E. H. (1995) · The FASEB Journal · doi:10.1096/fasebj.9.5.7896017 · Cited by 783
Cowin, S. C. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00161-4 · Cited by 780
In vivo measurement of human tibial strains during vigorous activity
Burr, D. B., Milgrom, C., Fyhrie, D., Forwood, M., Nyska, M., Finestone, A., Hoshaw, S., Saiag, E., & Simkin, A. (1996) · Bone · doi:10.1016/8756-3282(96)00028-2 · Cited by 712
Mooseker, M. S., & Tilney, L. G. (1975) · The Journal of cell biology · doi:10.1083/jcb.67.3.725 · Cited by 622
Rubin, C., Recker, R., Cullen, D., Ryaby, J., McCabe, J., & McLeod, K. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.0301251 · Cited by 592
Mechanotransduction and strain amplification in osteocyte cell processes
Han, Y., Cowin, S. C., Schaffler, M. B., & Weinbaum, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407429101 · Cited by 496
Self-citation
Cited by
The Osteocyte: An Endocrine Cell … and More
Dallas, S. L., Prideaux, M., & Bonewald, L. F. (2013) · Endocrine Reviews · doi:10.1210/er.2012-1026 · Cited by 1,042
The Mechanical World of Bacteria
Persat, A., Nadell, C. D., Kim, M. K., Ingremeau, F., Siryaporn, A., Drescher, K., Wingreen, N. S., Bassler, B. L., Gitai, Z., & Stone, H. A. (2015) · Cell · doi:10.1016/j.cell.2015.05.005 · Cited by 615
Biomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Mechanosensation and transduction in osteocytes
Klein-Nulend, J., Bakker, A. D., Bacabac, R. G., Vatsa, A., & Weinbaum, S. (2013) · Bone · doi:10.1016/j.bone.2012.10.013 · Cited by 528
“Numerous tracer studies have been conducted, which are summarized by Fritton and Weinbaum [36].”
BackgroundMethodSelf-citationZhu, G., Zhang, T., Chen, M., Yao, K., Huang, X., Zhang, B., Li, Y., Liu, J., Wang, Y., & Zhao, Z. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.03.043 · Cited by 494
Mechanobiology and Developmental Control
Mammoto, T., Mammoto, A., & Ingber, D. E. (2013) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-101512-122340 · Cited by 443
Boning up on Wolff's Law: Mechanical regulation of the cells that make and maintain bone
Chen, J.-H., Liu, C., You, L., & Simmons, C. A. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.016 · Cited by 422
Bone physiology as inspiration for tissue regenerative therapies
Lopes, D., Martins-Cruz, C., Oliveira, M. B., & Mano, J. F. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.028 · Cited by 421
Recent Advances in Hydroxyapatite-Based Biocomposites for Bone Tissue Regeneration in Orthopedics
Ielo, I., Calabrese, G., De Luca, G., & Conoci, S. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23179721 · Cited by 386
The Key Role of the Blood Supply to Bone
Marenzana, M., & Arnett, T. R. (2013) · Bone Research · doi:10.4248/br201303001 · Cited by 366
Department of Oral Cell Biology, R. I. M., Klein-Nulend, J., Bacabac, R., & Bakker, A. (2012) · European Cells and Materials · doi:10.22203/ecm.v024a20 · Cited by 336
Price, C., Zhou, X., Li, W., & Wang, L. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.211 · Cited by 279
Bioinspired mineralized collagen scaffolds for bone tissue engineering
Li, Z., Du, T., Ruan, C., & Niu, X. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.11.004 · Cited by 272
Mechanical stress-activated integrin α5β1 induces opening of connexin 43 hemichannels
Batra, N., Burra, S., Siller-Jackson, A. J., Gu, S., Xia, X., Weber, G. F., DeSimone, D., Bonewald, L. F., Lafer, E. M., Sprague, E., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1115967109 · Cited by 240
“Mechanical forces applied to the bone cause fluid flow through the lacunar–canalicular network surrounding the osteocyte (2).”
BackgroundBlood and interstitial flow in the hierarchical pore space architecture of bone tissue
Cowin, S. C., & Cardoso, L. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.013 · Cited by 174
“…(pores) of the lacunar-canalicular porosity are the principal mechanosensory cells of bone, and that they are activated by the induced drag from fluid flowing through the lacunar-canalicular porosity (Weinbaum et al., 1994; Cowin et al., 1995; Sharma et al., 2007; Fritton and Weinbaum, 2009).”
BackgroundInfluentialTowards quantitative 3D imaging of the osteocyte lacuno-canalicular network
Schneider, P., Meier, M., Wepf, R., & Müller, R. (2010) · Bone · doi:10.1016/j.bone.2010.07.026 · Cited by 172
“Possible strain sensing mechanisms include direct strain sensation by the osteocyte due to matrix deformations or indirect strain sensation mediated by fluid flow [10–15].”
BackgroundEffects of cyclic hydraulic pressure on osteocytes
Liu, C., Zhao, Y., Cheung, W.-Y., Gandhi, R., Wang, L., & You, L. (2010) · Bone · doi:10.1016/j.bone.2010.02.006 · Cited by 88
“The strain in bone tissue in response to mechanical loads induces the pressure gradient within interstitial fluid and induces its movement within the bone pores, from the lacunar-canalicular system where osteocytes, the putative mechanosensor cells in bone, reside to the vascular system [42] [43-46] (reviewed in [47]).”
A FAK/HDAC5 signaling axis controls osteocyte mechanotransduction
Sato, T., Verma, S., Andrade, C. D. C., Omeara, M., Campbell, N., Wang, J. S., Cetinbas, M., Lang, A., Ausk, B. J., Brooks, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17099-3 · Cited by 86
Sharma (2018) · doi:10.1016/j.bone.2018.01.019 · Cited by 70
“The vascular pores in cortical bone play an important role in load-induced interstitial fluid flow because they allow relaxation of fluid pressure in the lacunar-canalicular pores when bone is mechanically loaded [5, 6].”
BackgroundWu, W., Le, A. V., Mendez, J. J., Chang, J., Niklason, L. E., & Steinbacher, D. M. (2015) · Tissue Engineering Part A · doi:10.1089/ten.tea.2014.0115 · Cited by 44
“Native osteoblasts and their progenitors within bony matrices are constantly subjected to interstitial fluid perfusion and shear stress.(12) Both BMCs and ACs are mechanosensitive and osteogenically responsive to fluid flow.”
Background
Metadata
- Authors
- Fritton, S. P., & Weinbaum, S.
- Venue
- Annual Review of Fluid Mechanics
- Publisher
- Annual Reviews
- Published
- 2009-01-01
- Volume
- 41
- Issue
- 1
- Pages
- 347-374
- ISSN
- 0066-4189 (ISSN-L)
- 1545-4479
- OpenAlex
- W2155736277
- Cited by
- 380
- References
- 130
- FWCI
- 0.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.