IMAGING AND CONTROL OF DOMAIN STRUCTURES IN FERROELECTRIC THIN FILMS VIA SCANNING FORCE MICROSCOPY
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
▪ Abstract Scanning force microscopy (SFM) is becoming a powerful technique with great potential both for imaging and for control of domain structures in ferroelectric materials at the nanometer scale. Application of SFM to visualization of domain structures in ferroelectric thin films is described. Imaging methods of ferroelectric domains are based on the detection of surface charges in the noncontact mode of SFM and on the measurement of the piezoelectric response of a ferroelectric film to an external field applied by the tip in the SFM contact mode. This latter mode can be used for nondestructive evaluation of local ferroelectric and piezoelectric properties and for manipulation of domains of less than 50 nm in diameter. The effect of the film thickness and crystallinity on the imaging resolution is discussed. Scanning force microscopy is shown to be a technique well suited for nanoscale investigation of switching processes and electrical degradation effects in ferroelectric thin films.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Scott, J. F., & Paz de Araujo, C. A. (1989) · Science · doi:10.1126/science.246.4936.1400 · Cited by 3,863
Scanning Probe Microscopy and Spectroscopy: Methods and Applications
Wiesendanger, R. (1994) · Cambridge University Press eBooks · doi:10.1017/cbo9780511524356 · Cited by 1,645
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Scanning force microscopy - With Applications to Electric, Magnetic and Atomic Forces
Sarid, D., Coratger, R., Ajustron, F., & Beauvillain, J. (1991) · Microscopy Microanalysis Microstructures · doi:10.1051/mmm:0199100206064900 · Cited by 563
Contact electrification using force microscopy
Terris, B. D., Stern, J. E., Rugar, D., & Mamin, H. J. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.2669 · Cited by 531
Local poling of ferroelectric polymers by scanning force microscopy
Güthner, P., & Dransfeld, K. (1992) · Applied Physics Letters · doi:10.1063/1.107693 · Cited by 350
Scanning tunneling microscopy and spectroscopy: Theory, techniques, and applications
Bonnell, D. A. (1993) · Medical Entomology and Zoology · Cited by 278
Local, Nonvolatile Electronic Writing of Epitaxial Pb(Zr 0.52 Ti 0.48 )O 3 /SrRuO 3 Heterostructures
Ahn, C. H., Tybell, T., Antognazza, L., Char, K., Hammond, R. H., Beasley, M. R., Fischer, Ø., & Triscone, J.-M. (1997) · Science · doi:10.1126/science.276.5315.1100 · Cited by 266
Imaging of ferroelectric domain walls by force microscopy
Saurenbach, F., & Terris, B. D. (1990) · Applied Physics Letters · doi:10.1063/1.103122 · Cited by 238
Surface and domain structures of ferroelectric crystals studied with scanning force microscopy
Lüthi, R., Haefke, H., Meyer, K.-P., Meyer, E., Howald, L., & Güntherodt, H.-J. (1993) · Journal of Applied Physics · doi:10.1063/1.354969 · Cited by 159
Scanning maxwell stress microscope for nanometre-scale surface electrostatic imaging of thin films
Yokoyama, H., & Inoue, T. (1994) · Thin Solid Films · doi:10.1016/0040-6090(94)90497-9 · Cited by 111
Deconvolution of topographic and ferroelectric contrast by noncontact and friction force microscopy
Eng, L. M., Friedrich, M., Fousek, J., & Günter, P. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.588512 · Cited by 73
Cited by
Dynamics of ferroelastic domains in ferroelectric thin films
Nagarajan, V., Roytburd, A., Stanishevsky, A., Prasertchoung, S., Zhao, T., Chen, L., Melngailis, J., Auciello, O., & Ramesh, R. (2003) · Nature Materials · doi:10.1038/nmat800 · Cited by 569
Self-citationImaging mechanism of piezoresponse force microscopy of ferroelectric surfaces
Kalinin, S. V., & Bonnell, D. A. (2002) · Physical Review B · doi:10.1103/physrevb.65.125408 · Cited by 506
Direct Observation of Ferroelectric Domains in Solution-Processed CH3NH3PbI3 Perovskite Thin Films
Kutes, Y., Ye, L., Zhou, Y., Pang, S., Huey, B. D., & Padture, N. P. (2014) · The Journal of Physical Chemistry Letters · doi:10.1021/jz501697b · Cited by 451
Electric Field-Induced Magnetization Switching in Epitaxial Columnar Nanostructures
Zavaliche, F., Zheng, H., Mohaddes-Ardabili, L., Yang, S. Y., Zhan, Q., Shafer, P., Reilly, E., Chopdekar, R., Jia, Y., Wright, P., et al. (2005) · Nano Letters · doi:10.1021/nl051406i · Cited by 448
Two-dimensional materials with piezoelectric and ferroelectric functionalities
Cui, C., Xue, F., Hu, W.-J., & Li, L.-J. (2018) · npj 2D Materials and Applications · doi:10.1038/s41699-018-0063-5 · Cited by 446
Metadata
- Authors
- Gruverman, A., Auciello, O., & Tokumoto, H.
- Venue
- Annual Review of Materials Science
- Publisher
- Annual Reviews
- Published
- 1998-08
- Volume
- 28
- Issue
- 1
- Pages
- 101-123
- ISSN
- 0084-6600 (ISSN-L)
- OpenAlex
- W2166723564
- Cited by
- 495
- References
- 13
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.