Multi–Detector Row CT of Thoracic Disease with Emphasis on 3D Volume Rendering and CT Angiography
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Multi-detector row computed tomography (CT) with three-dimensional (3D) volume rendering provides a unique perspective on thoracic anatomy and disease. Multi-detector row CT allows shorter acquisition times, greater coverage, and superior image resolution. Three-dimensional volume rendering now permits real-time, interactive modification of relative pixel attenuation in an infinite number of planes and projections. In vascular imaging, this technique provides image quality that equals or surpasses that of conventional angiography. Its use has expanded to aid in diagnosis and surgical planning, often obviating conventional or digital angiography and reducing costs. It is reliable in depicting clot and the pulmonary vasculature and may also be used to evaluate thoracic venous anomalies (eg, pulmonary arteriovenous malformations) and to plan therapy. Airway imaging with multi-detector row CT with 3D volume rendering is particularly useful in the planning and follow-up of stent placement. In diffuse lung disease, this technique can increase nodule detection and help differentiate between small nodules and vessels. It is also helpful in imaging the musculoskeletal system and the thoracic cage. Multi-detector row CT with 3D volume rendering has enhanced the conventional roles of thoracic CT and challenged the supremacy of other imaging modalities. It will likely play a leading role in future radiologic research and practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Early Lung Cancer Action Project: overall design and findings from baseline screening
Henschke, C. I., McCauley, D. I., Yankelevitz, D. F., Naidich, D. P., McGuinness, G., Miettinen, O. S., Libby, D. M., Pasmantier, M. W., Koizumi, J., Altorki, N. K., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(99)06093-6 · Cited by 2,508
Mass screening for lung cancer with mobile spiral computed tomography scanner
Sone, S., Takashima, S., Li, F., Yang, Z., Honda, T., Maruyama, Y., Hasegawa, M., Yamanda, T., Kubo, K., Hanamura, K., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08229-9 · Cited by 931
Remy-Jardin, M., Remy, J., Wattinne, L., & Giraud, F. (1992) · Radiology · doi:10.1148/radiology.185.2.1410342 · Cited by 788
Callister, T. Q., Raggi, P., Cooil, B., Lippolis, N. J., & Russo, D. J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392703 · Cited by 682
Three-dimensional Volume Rendering of Spiral CT Data: Theory and Method
Calhoun, P. S., Kuszyk, B. S., Heath, D. G., Carley, J. C., & Fishman, E. K. (1999) · RadioGraphics · doi:10.1148/radiographics.19.3.g99ma14745 · Cited by 550
Self-citationIncidence of venous thromboembolism verified by necropsy over 30 years.
Lindblad, B., Sternby, N. H., & Bergqvist, D. (1991) · BMJ · doi:10.1136/bmj.302.6778.709 · Cited by 386
Sommer, T., Fehske, W., Holzknecht, N., von Smekal, A., Keller, E., Lutterbey, G. G., Kreft, B., Kuhl, C. K., Gieseke, J., Abu-Ramadan, D., et al. (1996) · Radiology · doi:10.1148/radiology.199.2.8668776 · Cited by 373
CT angiography with spiral CT and maximum intensity projection.
Napel, S. A., Marks, M. P., Rubin, G. D., et al. (1992) · Radiology · doi:10.1148/radiology.185.2.1410382 · Cited by 364
O’Malley, P. G., Taylor, A. J., Jackson, J. L., Doherty, T. M., & Detrano, R. C. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00906-6 · Cited by 293
Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT Angiography
Rubin, G. D., Shiau, M. C., Leung, A. N., Kee, S. T., Logan, L. J., & Sofilos, M. C. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn18670 · Cited by 248
Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol.
Remy-Jardin, M., Remy, J., Artaud, D., Deschildre, F., & Duhamel, A. (1997) · Radiology · doi:10.1148/radiology.204.1.9205239 · Cited by 208
Stein, P. D., Henry, J. W., & Gottschalk, A. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr41689 · Cited by 204
Johnson, P. T., Halpern, E. J., Kuszyk, B. S., et al. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ap17337 · Cited by 152
Unsuspected pulmonary embolism: prospective detection on routine helical CT scans.
Gosselin, M. V., Rubin, G. D., Leung, A. N. C., Huang, J., & Rizk, N. W. (1998) · Radiology · doi:10.1148/radiology.208.1.9646815 · Cited by 151
Becker, C. R., Jakobs, T. F., Aydemir, S., Becker, A., Knez, A., Schoepf, U. J., Bruening, R. D., Haberl, R., & Reiser, M. F. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.2.1740543 · Cited by 138
Rémy‐Jardin, M., Rémy, J., Gosselin, B., Copin, M., Würtz, A., & Duhamel, A. (1996) · Radiology · doi:10.1148/radiology.200.3.8756912 · Cited by 106
Quint, L. E., Francis, I. R., Williams, D. M., Bass, J. C., Shea, M. J., Frayer, D. L., Monaghan, H. M., & Deeb, G. M. (1996) · Radiology · doi:10.1148/radiology.201.1.8816517 · Cited by 100
Zeman, R. K., Silverman, P. M., Vieco, P. T., & Costello, P. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.165.5.7572481 · Cited by 68
Cost Identification of Abdominal Aortic Aneurysm Imaging by Using Time and Motion Analyses
Rubin, G. D., Armerding, M. D., Dake, M. D., & Napel, S. A. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap4863 · Cited by 45
Cited by
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Mahesh, M. (2002) · RadioGraphics · doi:10.1148/radiographics.22.4.g02jl14949 · Cited by 196
Siegel, M. J. (2003) · Radiology · doi:10.1148/radiol.2293020999 · Cited by 180
Metadata
- Authors
- Lawler, L. P., & Fishman, E. K.
- Venue
- RadioGraphics
- Published
- 2001-09
- Volume
- 21
- Issue
- 5
- Pages
- 1257-1273
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2135906100
- Cited by
- 176
- References
- 21
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.