Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Phase-contrast magnetic resonance (MR) imaging is a well-known but undervalued method of obtaining quantitative information on blood flow. Applications of this technique in cardiovascular MR imaging are expanding. According to the sequences available, phase-contrast measurement can be performed in a breath hold or during normal respiration. Prospective as well as retrospective gating techniques can be used. Common errors in phase-contrast imaging include mismatched encoding velocity, deviation of the imaging plane, inadequate temporal resolution, inadequate spatial resolution, accelerated flow and spatial misregistration, and phase offset errors. Flow measurements are most precise if the imaging plane is perpendicular to the vessel of interest and flow encoding is set to through-plane flow. The sequence should be repeated at least once, with a high encoding velocity used initially. If peak velocity has to be estimated, flow measurement is repeated with an adapted encoding velocity. The overall error of a phase-contrast flow measurement comprises errors during prescription as well as errors that occur during image analysis of the flow data. With phase-contrast imaging, the overall error in flow measurement can be reduced to less than 10%, an acceptable level of error for routine clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flow velocity zeugmatographic interlace for NMR imaging in humans
Moran, P. R. (1982) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(82)90170-9 · Cited by 745
Natural history of coarctation of the aorta
Campbell, M. (1970) · Heart · doi:10.1136/hrt.32.5.633 · Cited by 614
Kondo, C., Caputo, G. R., Semelka, R., Foster, E., Shimakawa, A., & Higgins, C. B. (1991) · American Journal of Roentgenology · doi:10.2214/ajr.157.1.2048544 · Cited by 260
Blood Flow Rates by Nuclear Magnetic Resonance Measurements
Singer, J. R. (1959) · Science · doi:10.1126/science.130.3389.1652 · Cited by 248
Hundley, W. G., Li, H. F., Willard, J. E., Landau, C., Lange, R. A., Meshack, B. M., Hillis, L. D., & Peshock, R. M. (1995) · Circulation · doi:10.1161/01.cir.92.5.1151 · Cited by 229
EVANS, A. J., IWAI, F., Grist, T. M., Sostman, H. D., Hedlund, L. W., Spritzer, C. E., Negro‐Vilar, R., Beam, C. A., & Pelc, N. J. (1993) · Investigative Radiology · doi:10.1097/00004424-199302000-00004 · Cited by 160
Schwitter, J., DeMarco, T., Kneifel, S., von Schulthess, G. K., Jörg-Ciopor, M., Arheden, H., Rühm, S., Stumpe, K. O., Buck, A., Parmley, W. W., et al. (2000) · Circulation · doi:10.1161/01.cir.101.23.2696 · Cited by 159
NMR blood flow imaging using multiecho, phase contrast sequences
O'Donnell, M. (1985) · Medical Physics · doi:10.1118/1.595736 · Cited by 158
Hofman, M. B. M., Visser, F. C., van Rossum, A. C., Vink, G. Q. M., Sprenger, M., & Westerhof, N. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330606 · Cited by 152
Maier, S. E., Meier, D., Boesiger, P., Moser, U., & Vieli, A. (1989) · Radiology · doi:10.1148/radiology.171.2.2649924 · Cited by 140
Determinants of normal coronary artery dimensions in humans.
Leung, T. W. H., Stadius, M. L., & Alderman, E. L. (1991) · Circulation · doi:10.1161/01.cir.84.6.2294 · Cited by 117
Lee, V. S., Spritzer, C. E., Carroll, B. A., Pool, L. G., Bernstein, M. A., Heinle, S. K., & MacFall, J. R. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.169.4.9308476 · Cited by 111
Hoeper, M. M., Tongers, J., Leppert, A., Baus, S., Maier, R., & Lotz, J. (2001) · CHEST Journal · doi:10.1378/chest.120.2.502 · Cited by 105
Self-citationAnalysis of noise in phase contrast MR imaging
Andersen, A. H., & KIRSCH, J. E. (1996) · Medical Physics · doi:10.1118/1.597729 · Cited by 102
Hundley, W. G., Hamilton, C. A., Clarke, G. D., Hillis, L. D., Herrington, D. M., Lange, R. A., Applegate, R. J., Thomas, M. S., Payne, J., Link, K. M., et al. (1999) · Circulation · doi:10.1161/01.cir.99.25.3248 · Cited by 75
MR velocity mapping of tricuspid flow: Correction for through‐plane motion
Kayser, H. W. M., Stoel, B. C., van der Wall, E. E., Geest, R. J. D. V., & Roos, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070410 · Cited by 74
Hundley, W. G., Hillis, L. D., Hamilton, C. A., Applegate, R. J., Herrington, D. M., Clarke, G. D., Braden, G. A., Thomas, M. S., Lange, R. A., Peshock, R. M., et al. (2000) · Circulation · doi:10.1161/01.cir.101.20.2375 · Cited by 67
Mohiaddin, R. H., Gatehouse, P. D., Henien, M., & Firmin, D. N. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070408 · Cited by 51
Yang, G. Z., Burger, P., Kilner, P. J., Karwatowski, S. P., & Firmin, D. N. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060313 · Cited by 50
Clarke, G. D., Hundley, W. G., McColl, R. W., Eckels, R., Smith, D., Li, H., & Peshock, R. M. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060506 · Cited by 28
Cited by
Schulz-Menger, J., Bluemke, D. A., Bremerich, J., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Kim, R. J., von Knobelsdorff-Brenkenhoff, F., Kramer, C. M., Pennell, D. J., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-35 · Cited by 2,097
van Wolferen, S. A., Marcus, J. T., Boonstra, A., Marques, K. M. J., Bronzwaer, J. G. F., Spreeuwenberg, M. D., Postmus, P. E., & Vonk-Noordegraaf, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl477 · Cited by 753
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Kawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Sun, L., Macgowan, C. K., Sled, J. G., Yoo, S.-J., Manlhiot, C., Porayette, P., Grosse-Wortmann, L., Jaeggi, E., McCrindle, B. W., Kingdom, J., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.013051 · Cited by 533
Metadata
- Authors
- Lotz, J., Meier, C., Leppert, A., & Galanski, M.
- Venue
- RadioGraphics
- Published
- 2002-05
- Volume
- 22
- Issue
- 3
- Pages
- 651-671
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2100082339
- Cited by
- 673
- References
- 20
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.