Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Phase-contrast magnetic resonance (MR) imaging is a well-known but undervalued method of obtaining quantitative information on blood flow. Applications of this technique in cardiovascular MR imaging are expanding. According to the sequences available, phase-contrast measurement can be performed in a breath hold or during normal respiration. Prospective as well as retrospective gating techniques can be used. Common errors in phase-contrast imaging include mismatched encoding velocity, deviation of the imaging plane, inadequate temporal resolution, inadequate spatial resolution, accelerated flow and spatial misregistration, and phase offset errors. Flow measurements are most precise if the imaging plane is perpendicular to the vessel of interest and flow encoding is set to through-plane flow. The sequence should be repeated at least once, with a high encoding velocity used initially. If peak velocity has to be estimated, flow measurement is repeated with an adapted encoding velocity. The overall error of a phase-contrast flow measurement comprises errors during prescription as well as errors that occur during image analysis of the flow data. With phase-contrast imaging, the overall error in flow measurement can be reduced to less than 10%, an acceptable level of error for routine clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flow velocity zeugmatographic interlace for NMR imaging in humans
Moran, P. R. (1982) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(82)90170-9 · Cited by 745
Natural history of coarctation of the aorta
Campbell, M. (1970) · Heart · doi:10.1136/hrt.32.5.633 · Cited by 614
Kondo, C., Caputo, G. R., Semelka, R., Foster, E., Shimakawa, A., & Higgins, C. B. (1991) · American Journal of Roentgenology · doi:10.2214/ajr.157.1.2048544 · Cited by 260
Blood Flow Rates by Nuclear Magnetic Resonance Measurements
Singer, J. R. (1959) · Science · doi:10.1126/science.130.3389.1652 · Cited by 248
Hundley, W. G., Li, H. F., Willard, J. E., Landau, C., Lange, R. A., Meshack, B. M., Hillis, L. D., & Peshock, R. M. (1995) · Circulation · doi:10.1161/01.cir.92.5.1151 · Cited by 229
EVANS, A. J., IWAI, F., Grist, T. M., Sostman, H. D., Hedlund, L. W., Spritzer, C. E., Negro‐Vilar, R., Beam, C. A., & Pelc, N. J. (1993) · Investigative Radiology · doi:10.1097/00004424-199302000-00004 · Cited by 160
Schwitter, J., DeMarco, T., Kneifel, S., von Schulthess, G. K., Jörg-Ciopor, M., Arheden, H., Rühm, S., Stumpe, K. O., Buck, A., Parmley, W. W., et al. (2000) · Circulation · doi:10.1161/01.cir.101.23.2696 · Cited by 159
NMR blood flow imaging using multiecho, phase contrast sequences
O'Donnell, M. (1985) · Medical Physics · doi:10.1118/1.595736 · Cited by 158
Hofman, M. B. M., Visser, F. C., van Rossum, A. C., Vink, G. Q. M., Sprenger, M., & Westerhof, N. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330606 · Cited by 152
Maier, S. E., Meier, D., Boesiger, P., Moser, U., & Vieli, A. (1989) · Radiology · doi:10.1148/radiology.171.2.2649924 · Cited by 140
Cited by
Schulz-Menger, J., Bluemke, D. A., Bremerich, J., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Kim, R. J., von Knobelsdorff-Brenkenhoff, F., Kramer, C. M., Pennell, D. J., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-35 · Cited by 2,097
van Wolferen, S. A., Marcus, J. T., Boonstra, A., Marques, K. M. J., Bronzwaer, J. G. F., Spreeuwenberg, M. D., Postmus, P. E., & Vonk-Noordegraaf, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl477 · Cited by 753
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Kawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Sun, L., Macgowan, C. K., Sled, J. G., Yoo, S.-J., Manlhiot, C., Porayette, P., Grosse-Wortmann, L., Jaeggi, E., McCrindle, B. W., Kingdom, J., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.013051 · Cited by 533
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Blood Flow Distribution in Cerebral Arteries
Zarrinkoob, L., Ambarki, K., Wåhlin, A., Birgander, R., Eklund, A., & Malm, J. (2015) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.241 · Cited by 365
Orešković, D., & Klarica, M. (2010) · Brain Research Reviews · doi:10.1016/j.brainresrev.2010.04.006 · Cited by 338
Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
Gatehouse, P. D., Keegan, J., Crowe, L. A., Masood, S., Mohiaddin, R. H., Kreitner, K.-F., & Firmin, D. N. (2005) · European Radiology · doi:10.1007/s00330-005-2829-3 · Cited by 331
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
Bissell, M. M., Raimondi, F., Ait Ali, L., Allen, B. D., Barker, A. J., Bolger, A., Burris, N., Carhäll, C.-J., Collins, J. D., Ebbers, T., et al. (2023) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-023-00942-z · Cited by 296
E XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“This sensitivity arises due to the motion of spins within the flowing blood along the magnetic field gradients that are applied as part of the gradient echo pulse sequence [23,106].”
InfluentialGarcia, D., del Álamo, J. C., Tanné, D., Yotti, R., Cortina, C., Bertrand, É., Antoranz, J. C., Pérez-David, E., Rieu, R., Fernández-Avilés, F., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2049656 · Cited by 219
Greve, J. M., Les, A. S., Tang, B. T., Draney Blomme, M. T., Wilson, N. M., Dalman, R. L., Pelc, N. J., & Taylor, C. A. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00274.2006 · Cited by 175
“A velocity image can be calculated from the phase image, and velocity values for each voxel can be integrated over the cross-sectional area of the vessel to derive volumetric flow measurements (27, 31).”
BackgroundOgino, H., Iida, O., Akutsu, K., Chiba, Y., Hayashi, H., Ishibashi-Ueda, H., Kaji, S., Kato, M., Komori, K., Matsuda, H., et al. (2023) · Circulation Journal · doi:10.1253/circj.cj-22-0794 · Cited by 174
Prsa, M., Sun, L., van Amerom, J., Yoo, S.-J., Grosse-Wortmann, L., Jaeggi, E., Macgowan, C., & Seed, M. (2014) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.001859 · Cited by 168
“PC-MRI flow measurements made in adult blood vessels are more accurate than flow measurements made using ultrasound, with PC-MRI flows in the AAo and MPA agreeing to <3% in normal volunteers.(21) Flow turbulence and small vessel size affect the fidelity of the technique, although turbulence was not a particular concer…”
MethodChernobelsky, A., Shubayev, O., Comeau, C. R., & Wolff, S. D. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640601187588 · Cited by 163
Dyverfeldt, P., Sigfridsson, A., Kvitting, J. E., & Ebbers, T. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21022 · Cited by 162
The effect of supine positioning on maternal hemodynamics during late pregnancy
Humphries, A., Mirjalili, S. A., Tarr, G. P., Thompson, J. M. D., & Stone, P. (2019) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2018.1478958 · Cited by 133
“flow measurements [35,36], a small effect in compari-”
BackgroundMR Imaging of the Mesenteric Vasculature
Collins, J. D. (2020) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2020.03.001 · Cited by 7
Metadata
- Authors
- Lotz, J., Meier, C., Leppert, A., & Galanski, M.
- Venue
- RadioGraphics
- Published
- 2002-05
- Volume
- 22
- Issue
- 3
- Pages
- 651-671
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2100082339
- Cited by
- 673
- References
- 20
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.