The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Intraindividual Comparison of Gadoxetate Disodium–enhanced MR Imaging and 64-Section Multidetector CT in the Detection of Hepatocellular Carcinoma in Patients with Cirrhosis
Abstract
PURPOSE: To prospectively compare gadoxetate disodium-enhanced magnetic resonance (MR) imaging with multiphasic 64-section multidetector computed tomography (CT) in the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis. MATERIALS AND METHODS: Institutional review board approval and informed patient consent were obtained for this prospective study. Fifty-eight patients (39 men, 19 women; mean age, 63 years; age range, 35-84 years) underwent gadoxetate disodium-enhanced MR imaging and multiphasic 64-section multidetector CT. The imaging examinations were performed within 30 days of each other. The two sets of images were qualitatively analyzed in random order by three independent readers in a blinded and retrospective fashion. Using strict diagnostic criteria for HCC, readers classified all detected lesions with use of a four-point confidence scale. The reference standard was a combination of pathologic proof, conclusive imaging findings, and substantial tumor growth at follow-up CT or MR imaging (range of follow-up, 90-370 days). The diagnostic accuracy, sensitivity, and positive predictive value were compared between the two image sets. Interreader variability was assessed. The accuracy of each imaging method was determined by using an adjusted modified chi(2) test. RESULTS: Eighty-seven HCCs (mean size +/- standard deviation, 1.8 cm +/- 1.5; range, 0.3-7.0 cm) were confirmed in 42 of the 58 patients. Regardless of lesion size, the average diagnostic accuracy and sensitivity for all readers were significantly greater with gadoxetate disodium-enhanced MR imaging (average diagnostic accuracy: 0.88, 95% confidence interval [CI]: 0.80, 0.97; average sensitivity: 0.85, 95% CI: 0.74, 0.96) than with multidetector CT (average diagnostic accuracy: 0.74, 95% CI: 0.65, 0.82; average sensitivity: 0.69, 95% CI: 0.59, 0.79) (P < .001 for each). No significant difference in positive predictive value was observed between the two image sets for each reader. Interreader agreement was good to excellent. CONCLUSION: Compared with multiphasic 64-section multidetector CT, gadoxetate disodium-enhanced MR imaging yields significantly higher diagnostic accuracy and sensitivity in the detection of HCC in patients with cirrhosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Management of Hepatocellular Carcinoma *
Bruix, J., & Sherman, M. (2005) · Hepatology · doi:10.1002/hep.20933 · Cited by 5,857
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Terminology of nodular hepatocellular lesions
Wanless, I. R. (1995) · Hepatology · doi:10.1002/hep.1840220341 · Cited by 1,130
Livraghi, T., Meloni, F., Di Stasi, M., Rolle, E., Solbiati, L., Tinelli, C., & Rossi, S. (2008) · Hepatology · doi:10.1002/hep.21933 · Cited by 1,103
Forner, A., Vilana, R., Ayuso, C., Bianchi, L., Solé, M., Ayuso, J. R., Boix, L., Sala, M., Varela, M., Llovet, J. M., et al. (2008) · Hepatology · doi:10.1002/hep.21966 · Cited by 1,032
Surgical anatomy and anatomical surgery of the liver
Bismuth, H. (1982) · World Journal of Surgery · doi:10.1007/bf01656368 · Cited by 791
Converting Dose-Length Product to Effective Dose at CT
Huda, W., Ogden, K. M., & Khorasani, M. R. (2008) · Radiology · doi:10.1148/radiol.2483071964 · Cited by 513
MEDICAL RADIATION EXPOSURE IN THE U.S. IN 2006: PRELIMINARY RESULTS
Mettler, F. A., Thomadsen, B. R., Bhargavan, M., Gilley, D. B., Gray, J. E., Lipoti, J. A., McCrohan, J., Yoshizumi, T. T., & Mahesh, M. (2008) · Health Physics · doi:10.1097/01.hp.0000326333.42287.a2 · Cited by 507
Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA.
Vogl, T. J., Kümmel, S., Hammerstingl, R., Schellenbeck, M., Schumacher, G., Balzer, T., Schwarz, W., Müller, P. K., Bechstein, W. O., Mack, M. G., et al. (1996) · Radiology · doi:10.1148/radiology.200.1.8657946 · Cited by 453
Bolondi, L., Gaiani, S., Celli, N., Golfieri, R., Grigioni, W. F., Leoni, S., Venturi, A. M., & Piscaglia, F. (2005) · Hepatology · doi:10.1002/hep.20728 · Cited by 451
Huppertz, A., Balzer, T., Blakeborough, A., Breuer, J., Giovagnoni, A., Heinz-Peer, G., Laniado, M., Manfredi, R. M., Mathieu, D. G., Mueller, D., et al. (2004) · Radiology · doi:10.1148/radiol.2301020269 · Cited by 396
For the European EOB-study group, Hammerstingl, R., Huppertz, A., Breuer, J., Balzer, T., Blakeborough, A., Carter, R., Fusté, L. C., Heinz-Peer, G., Judmaier, W., et al. (2008) · European Radiology · doi:10.1007/s00330-007-0716-9 · Cited by 384
Huppertz, A., Haraida, S., Kraus, A., Zech, C. J., Scheidler, J., Breuer, J., Helmberger, T. K., & Reiser, M. F. (2005) · Radiology · doi:10.1148/radiol.2342040278 · Cited by 370
Contrast Agents for MR Imaging of the Liver
Semelka, R. C., & Helmberger, T. K. G. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja2427 · Cited by 337
Krinsky, G. A., Lee, V. S., Theise, N. D., Weinreb, J. C., Rofsky, N. M., Diflo, T., & Teperman, L. W. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma40445 · Cited by 332
Kim, S. H., Kim, S. H., Lee, J., Kim, M. J., Jeon, Y. H., Park, Y., Choi, D., Lee, W. J., & Lim, H. K. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1262 · Cited by 311
Yamashita, Y., Mitsuzaki, K., Yi, T., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M. (1996) · Radiology · doi:10.1148/radiology.200.1.8657948 · Cited by 272
Bluemke, D. A., Sahani, D., Amendola, M., Balzer, T., Breuer, J., Brown, J. J., Casalino, D. D., Davis, P. L., Francis, I. R., Krinsky, G., et al. (2005) · Radiology · doi:10.1148/radiol.2371031842 · Cited by 223
3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T
Chang, K. J., Kamel, I. R., Macura, K. J., & Bluemke, D. A. (2008) · RadioGraphics · doi:10.1148/rg.287075154 · Cited by 198
Halavaara, J., Breuer, J., Ayuso, C., Balzer, T., Bellin, M.-F., Blomqvist, L., Carter, R., Grazioli, L., Hammerstingl, R., Huppertz, A., et al. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200605000-00001 · Cited by 174
Lim, J. H., Kim, C. K., Lee, W. J., Park, C. K., Koh, K. C., Paik, S. W., & Joh, J. W. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.3.1750693 · Cited by 170
Frericks, B. B., Loddenkemper, C., Huppertz, A., Valdeig, S., Stroux, A., Seja, M., Wolf, K.-J., & Albrecht, T. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1946 · Cited by 140
Cited by
Lee, Y. J., Lee, J. M., Lee, J. S., Lee, H. Y., Park, B. H., Kim, Y. H., Han, J. K., & Choi, B. I. (2015) · Radiology · doi:10.1148/radiol.14140690 · Cited by 526
Primovist, Eovist: What to expect?
Van Beers, B. E., Pastor, C. M., & Hussain, H. K. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2012.01.031 · Cited by 407
Hiraoka, A., Michitaka, K., Kumada, T., Izumi, N., Kadoya, M., Kokudo, N., Kubo, S., Matsuyama, Y., Nakashima, O., Sakamoto, M., et al. (2017) · Liver Cancer · doi:10.1159/000479984 · Cited by 331
Kim, S. H., Kim, S. H., Lee, J., Kim, M. J., Jeon, Y. H., Park, Y., Choi, D., Lee, W. J., & Lim, H. K. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1262 · Cited by 311
Davenport, M. S., Viglianti, B. L., Al-Hawary, M. M., Caoili, E. M., Kaza, R. K., Liu, P. S. C., Maturen, K. E., Chenevert, T. L., & Hussain, H. K. (2013) · Radiology · doi:10.1148/radiol.12120826 · Cited by 262
Metadata
- Authors
- Di Martino, M., Marin, D., Guerrisi, A., Baski, M., Galati, F., Rossi, M., Brozzetti, S., Masciangelo, R., Passariello, R., & Catalano, C.
- Venue
- Radiology
- Published
- 2010-09
- Volume
- 256
- Issue
- 3
- Pages
- 806-816
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1985850914
- Cited by
- 259
- References
- 27
- FWCI
- 14.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.