The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Diffusion-weighted Imaging Improves the Diagnostic Accuracy of Conventional 3.0-T Breast MR Imaging
Open accessAbstract
PURPOSE: To evaluate the incremental value of diffusion-weighted (DW) imaging and apparent diffusion coefficient (ADC) mapping in relation to conventional breast magnetic resonance (MR) imaging in the characterization of benign versus malignant breast lesions at 3.0 T. MATERIALS AND METHODS: This retrospective HIPAA-compliant study was approved by the institutional review board, with the requirement for informed patient consent waived. Of 550 consecutive patients who underwent bilateral breast MR imaging over a 10-month period, 93 women with 101 lesions met the following study inclusion criteria: They had undergone three-dimensional (3D) high-spatial-resolution T1-weighted contrast material-enhanced MR imaging, dynamic contrast-enhanced MR imaging, and DW imaging examinations at 3.0 T and either had received a pathologic analysis-proven diagnosis (96 lesions) or had lesion stability confirmed at more than 2 years of follow-up (five lesions). DW images were acquired with b values of 0 and 600 sec/mm(2). Regions of interest were drawn on ADC maps of breast lesions and normal glandular tissue. Morphologic features (margin, enhancement pattern), dynamic contrast-enhanced MR results (semiquantitative kinetic curve data), absolute ADCs, and glandular tissue-normalized ADCs were included in multivariate models to predict a diagnosis of benign versus malignant lesion. RESULTS: Forty-one (44%) of the 93 patients were premenopausal, and 52 (56%) were postmenopausal. Thirty-three (32.7%) of the 101 lesions were benign, and 68 (67.3%) were malignant. Normalized ADCs were significantly different between the benign (mean ADC, 1.1 x 10(-3) mm(2)/sec +/- 0.4 [standard deviation]) and malignant (mean ADC, 0.55 x 10(-3) mm(2)/sec +/- 0.16) lesions (P < .001). Adding normalized ADCs to the 3D T1-weighted and dynamic contrast-enhanced MR data improved the diagnostic performance of MR imaging: The area under the receiver operating characteristic curve improved from 0.89 to 0.98, and the false-positive rate decreased from 36% (nine of 25 lesions) to 24% (six of 25 lesions). CONCLUSION: DW imaging with glandular tissue-normalized ADC assessment improves the characterization of breast lesions beyond the characterization achieved with conventional 3D T1-weighted and dynamic contrast-enhanced MR imaging at 3.0 T.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Kuhl, C. K., Mielcareck, P., Klaschik, S., Leutner, C., Wardelmann, E., Gieseke, J., & Schild, H. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap38101 · Cited by 1,277
Differentiation of clinically benign and malignant breast lesions using diffusion‐weighted imaging
Guo, Y., Cai, Y., Cai, Z., Gao, Y., An, N., Ma, L., Mahankali, S., & Gao, J. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10140 · Cited by 714
MRI for diagnosis of pure ductal carcinoma in situ: a prospective observational study
Kuhl, C. K., Schrading, S., Bieling, H. B., Wardelmann, E., Leutner, C. C., Koenig, R., Kuhn, W., & Schild, H. H. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61232-x · Cited by 711
Diagnostic Architectural and Dynamic Features at Breast MR Imaging: Multicenter Study
Schnall, M. D., Blume, J., Bluemke, D. A., DeAngelis, G. A., DeBruhl, N., Harms, S., Heywang-Köbrunner, S. H., Hylton, N., Kuhl, C. K., Pisano, E. D., et al. (2006) · Radiology · doi:10.1148/radiol.2381042117 · Cited by 514
Self-citationMagnetic Resonance Imaging of the Breast Prior to Biopsy
Bluemke, D. A. (2004) · JAMA · doi:10.1001/jama.292.22.2735 · Cited by 513
Self-citationADC Mapping of Benign and Malignant Breast Tumors
WOODHAMS, R., MATSUNAGA, K., KAN, S., HATA, H., OZAKI, M., IWABUCHI, K., KURANAMI, M., WATANABE, M., & HAYAKAWA, K. (2005) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.4.35 · Cited by 329
In vivo diffusion‐weighted MRI of the breast: Potential for lesion characterization
Sinha, S., Lucas‐Quesada, F. A., Sinha, U., DeBruhl, N., & Bassett, L. W. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10116 · Cited by 268
Kuhl, C. K., Schild, H. H., & Morakkabati, N. (2005) · Radiology · doi:10.1148/radiol.2363040811 · Cited by 263
Ikeda, D. M., Hylton, N. M., Kinkel, K., Hochman, M. G., Kuhl, C. K., Kaiser, W. A., Weinreb, J. C., Smazal, S. F., Degani, H., Viehweg, P., et al. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1127 · Cited by 250
Patterns of Enhancement on Breast MR Images: Interpretation and Imaging Pitfalls
Macura, K. J., Ouwerkerk, R., Jacobs, M. A., & Bluemke, D. A. (2006) · RadioGraphics · doi:10.1148/rg.266065025 · Cited by 243
Self-citationHawass, N. E. (1997) · The British Journal of Radiology · doi:10.1259/bjr.70.832.9166071 · Cited by 230
Kinkel, K., Helbich, T. H., Esserman, L. J., Barclay, J., Schwerin, E. H., Sickles, E. A., & Hylton, N. M. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.1.1750035 · Cited by 219
Detection of Breast Malignancy: Diagnostic MR Protocol for Improved Specificity
Huang, W., Fisher, P. R., Dulaimy, K., Tudorica, L. A., O’Hea, B., & Button, T. M. (2004) · Radiology · doi:10.1148/radiol.2322030547 · Cited by 219
Arabia, S. (1997) · Cited by 171
Flickinger, F. W., Allison, J. D., Sherry, R. M., & Wright, J. C. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90002-u · Cited by 148
Dynamic Contrast-Enhanced MRI of the Breast: Quantitative Method for Kinetic Curve Type Assessment
Khouli, R. H. E., Macura, K. J., Jacobs, M. A., Khalil, T. H., Kamel, I. R., Dwyer, A. A., & Bluemke, D. A. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2483 · Cited by 144
Self-citationA Combined Architectural and Kinetic Interpretation Model for Breast MR Images
Schnall, M. D., Rosten, S., Englander, S. A., Orel, S. G., & Nunes, L. W. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80683-9 · Cited by 90
Kneeshaw, P. J., Lowry, M., Manton, D. J., Hubbard, A., Drew, P. J., & Turnbull, L. (2005) · The Breast · doi:10.1016/j.breast.2005.05.002 · Cited by 88
Diffusion imaging of human breast
Englander, S. A., Uluğ, A. M., Brem, R. F., Glickson, J. D., & van Zijl, P. C. M. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199710)10:7<348::aid-nbm487>3.0.co;2-r · Cited by 82
Cited by
Diffusion-weighted breast MRI: Clinical applications and emerging techniques
Partridge, S. C., Nissan, N., Rahbar, H., Kitsch, A. E., & Sigmund, E. E. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25479 · Cited by 340
Malayeri, A. A., El Khouli, R. H., Zaheer, A., Jacobs, M. A., Corona-Villalobos, C. P., Kamel, I. R., & Macura, K. J. (2011) · RadioGraphics · doi:10.1148/rg.316115515 · Cited by 290
Self-citationDalmiş, M. U., Gubern-Mérida, A., Vreemann, S., Bult, P., Karssemeijer, N., Mann, R., & Teuwen, J. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000544 · Cited by 120
Identification of Breast Cancer Using Integrated Information from MRI and Mammography
Yang, S.-N., Li, F.-J., Liao, Y.-H., Chen, Y.-S., Shen, W.-C., & Huang, T.-C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0128404 · Cited by 36
Metadata
- Authors
- EI Khouli, R. H., Jacobs, M. A., Mezban, S. D., Huang, P., Kamel, I. R., Macura, K. J., & Bluemke, D. A.
- Venue
- Radiology
- Published
- 2010-07
- Volume
- 256
- Issue
- 1
- Pages
- 64-73
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2104568658
- Cited by
- 268
- References
- 20
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.