Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess the use of the dual-energy computed tomographic (CT) virtual noncalcium technique in the evaluation of bone marrow edema in vertebral compression fractures. MATERIALS AND METHODS: This prospective study was approved by the institutional review board; informed consent was obtained from all patients. Sixty-three consecutive patients with 112 thoracic and/or lumbar vertebral compression fractures were studied between January 2011 and April 2012. All patients underwent both dual-energy CT (100 kV and Sn140 kV, where Sn indicates the use of a 0.4-mm tin filter) and magnetic resonance (MR) imaging. Dual-energy CT data were postprocessed by using a three-material decomposition algorithm for generating noncalcium images of the collapsed bodies. Two radiologists evaluated for the presence of abnormal attenuation alterations in the bone marrow by using color-coded maps and measured CT numbers on noncalcium grayscale images. Bone sclerosis and intravertebral air were evaluated with CT scans. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic curve analysis. RESULTS: MR imaging depicted 46 edematous and 66 nonedematous vertebral compression fractures. Eighty-two bodies were classified as having less than 50% sclerosis and/or air. Significant differences in noncalcium CT numbers between edematous and nonedematous vertebral compression fractures were found for both readers (P < .0001). CT numbers for the diagnosis of bone marrow edema on the basis of MR imaging revealed areas under the receiver operating characteristic curve of 0.799 and 0.841 for readers 1 and 2, respectively (P = .56). Use of a cutoff value of -80 to differentiate edematous vertebral bodies resulted in a sensitivity of 96.3%, specificity of 98.2%, and accuracy of 97.6% in the group of vertebral bodies with less than 50% sclerosis and/or air. CONCLUSION: Dual-energy CT virtual noncalcium images were able to depict bone marrow in the collapsed vertebral bodies, especially in those with less than 50% sclerosis and/or air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vertebral fracture assessment using a semiquantitative technique
Genant, H. K., Wu, C. Y., van Kuijk, C., & Nevitt, M. C. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080915 · Cited by 3,691
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Klazen, C. A., Lohle, P. N., de Vries, J., Jansen, F. H., Tielbeek, A. V., Blonk, M. C., Venmans, A., van Rooij, W. J. J., Schoemaker, M. C., Juttmann, J. R., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60954-3 · Cited by 899
Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures.
Mathis, J. M., Barr, J. D., Belkoff, S. M., Barr, M. S., Jensen, M. E., & Deramond, H. (2001) · PubMed Central · Cited by 462
Coursey, C. A., Nelson, R. C., Boll, D. T., Paulson, E. K., Ho, L. M., Neville, A. M., Marin, D., Gupta, R. T., & Schindera, S. T. (2010) · RadioGraphics · doi:10.1148/rg.304095175 · Cited by 375
Pache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., et al. (2010) · Radiology · doi:10.1148/radiol.10091230 · Cited by 281
Diagnosis and management of vertebral fractures in elderly adults
Papaioannou, A., Watts, N. B., Kendler, D. L., Yuen, C. K., Adachi, J. D., & Ferko, N. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01190-7 · Cited by 237
Age- and sex-specific differences in the1H-spectrum of vertebral bone marrow
Kugel, H., Jung, C., Schulte, O., & Heindel, W. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200102)13:2<263::aid-jmri1038>3.0.co;2-m · Cited by 229
A comparison of morphometric definitions of vertebral fracture
Smith-Bindman, R., Cummings, S. R., Steiger, P., & Genant, H. K. (1991) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650060106 · Cited by 221
Guggenberger, R., Gnannt, R., Hodler, J., Krauss, B., Wanner, G. A., Csuka, E., Payne, B., Frauenfelder, T., Andreisek, G., & Alkadhi, H. (2012) · Radiology · doi:10.1148/radiol.12112217 · Cited by 159
Schellinger, D., Lin, C. S., Fertikh, D., Lee, J. S., Lauerman, W. C., Henderson, F. C., & Davis, B. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn42910 · Cited by 117
“Occult” Osteoporotic Vertebral Fractures: Vertebral Body Fractures Without Radiologic Collapse
Pham, T., Parrado-Azulay, J., Champsaur, P., Chagnaud, C., Legré-Boyer, V., & Lafforgue, P. (2005) · Spine · doi:10.1097/01.brs.0000184303.86932.77 · Cited by 84
Traumatic bone bruising—A review article
Mandalia, V., & Henson, J. H. L. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.01.060 · Cited by 70
Faciszewski, T., & McKiernan, F. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.2.185 · Cited by 58
Pache, G., Bulla, S., Baumann, T., Bayer, J., Reising, K., Strohm, P. C., Langer, M., & Blanke, P. (2012) · Academic Radiology · doi:10.1016/j.acra.2012.08.006 · Cited by 42
Cited by
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Metadata
- Authors
- Wang, C.-K., Tsai, J.-M., Chuang, M.-T., Wang, M.-T., Huang, K.-Y., & Lin, R.-M.
- Venue
- Radiology
- Published
- 2013-11
- Volume
- 269
- Issue
- 2
- Pages
- 525-533
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2104806088
- Cited by
- 177
- References
- 16
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.