STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Incomplete reporting has been identified as a major source of avoidable waste in biomedical research. Essential information is often not provided in study reports, impeding the identification, critical appraisal, and replication of studies. To improve the quality of reporting of diagnostic accuracy studies, the Standards for Reporting of Diagnostic Accuracy Studies (STARD) statement was developed. Here we present STARD 2015, an updated list of 30 essential items that should be included in every report of a diagnostic accuracy study. This update incorporates recent evidence about sources of bias and variability in diagnostic accuracy and is intended to facilitate the use of STARD. As such, STARD 2015 may help to improve completeness and transparency in reporting of diagnostic accuracy studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the process of cross-cultural adaptation of self-report measures
Beaton, D. E., Bombardier, C., Guillemin, F., & Ferraz, M. B. (2000) · Spine · doi:10.1097/00007632-200012150-00014 · Cited by 14,542
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · BMJ · doi:10.1136/bmj.g7594 · Cited by 4,388
Self-citationTowards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Self-citationTowards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Self-citationTowards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Self-citationEmpirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 1×
“Despite their apparent simplicity, such studies are at risk of bias (6, 7).”
BackgroundSelf-citationReducing waste from incomplete or unusable reports of biomedical research
Glasziou, P., Altman, D. G., Bossuyt, P., Boutron, I., Clarke, M., Julious, S., Michie, S., Moher, D., & Wager, E. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62228-x · Cited by 1,319
Self-citationPolicy: NIH plans to enhance reproducibility
Collins, F. S., & Tabak, L. A. (2014) · Nature · doi:10.1038/505612a · Cited by 1,247
CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials.
Schulz, K. F., Altman, D. G., & Moher, D. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.02.005 · Cited by 1,022
Self-citationBoutron, I. (2010) · JAMA · doi:10.1001/jama.2010.651 · Cited by 842
Cited by
Ahmed, H. U., El-Shater Bosaily, A., Brown, L. C., Gabe, R., Kaplan, R., Parmar, M. K., Collaco-Moraes, Y., Ward, K., Hindley, R. G., Freeman, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(16)32401-1 · Cited by 3,284
McInnes, M. D. F., Moher, D., Thombs, B. D., McGrath, T. A., Bossuyt, P. M., and the PRISMA-DTA Group, Clifford, T., Cohen, J. F., Deeks, J. J., Gatsonis, C., et al. (2018) · JAMA · doi:10.1001/jama.2017.19163 · Cited by 3,210
Self-citationChecklist for Artificial Intelligence in Medical Imaging (CLAIM): a guide for authors and reviewers
Mongan, J., Moy, L., & Kahn, C. E. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020200029 · Cited by 1,443
Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00438-z · Cited by 946
Park, S. H., & Han, K. (2018) · Radiology · doi:10.1148/radiol.2017171920 · Cited by 894
Considerations for diagnostic COVID-19 tests
Vandenberg, O., Martiny, D., Rochas, O., van Belkum, A., & Kozlakidis, Z. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-020-00461-z · Cited by 803
Page, M. J., & Moher, D. (2017) · Systematic Reviews · doi:10.1186/s13643-017-0663-8 · Cited by 769
Self-citationObuchowski, N. A., & Bullen, J. A. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aab4b1 · Cited by 542
Canadian Association of Radiologists White Paper on Artificial Intelligence in Radiology
Tang, A., Tam, R., Cadrin-Chênevert, A., Guest, W., Chong, J., Barfett, J., Chepelev, L., Cairns, R., Mitchell, J. R., Cicero, M. D., et al. (2018) · Canadian Association of Radiologists Journal · doi:10.1016/j.carj.2018.02.002 · Cited by 522
Self-citationSchaffter, T., Buist, D. S. M., Lee, C. I., Nikulin, Y., Ribli, D., Guan, Y., Lotter, W., Jie, Z., Du, H., Wang, S., et al. (2020) · JAMA Network Open · doi:10.1001/jamanetworkopen.2020.0265 · Cited by 409
External Validation of Deep Learning Algorithms for Radiologic Diagnosis: A Systematic Review
Yu, A. C., Mohajer, B., & Eng, J. (2022) · Radiology: Artificial Intelligence · doi:10.1148/ryai.210064 · Cited by 408
The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence
Sounderajah, V., Guni, A., Liu, X., Collins, G. S., Karthikesalingam, A., Markar, S. R., Golub, R. M., Denniston, A. K., Shetty, S., Moher, D., et al. (2025) · Nature Medicine · doi:10.1038/s41591-025-03953-8 · Cited by 592
Self-citationSechopoulos, I., Rogers, D. W. O., Bazalova‐Carter, M., Bolch, W. E., Heath, E. C., McNitt‐Gray, M. F., Sempau, J., & Williamson, J. F. (2018) · Medical Physics · doi:10.1002/mp.12702 · Cited by 302
AI pitfalls and what not to do: mitigating bias in AI
Gichoya, J. W., Thomas, K., Celi, L. A., Safdar, N., Banerjee, I., Banja, J. D., Seyyed-Kalantari, L., Trivedi, H., & Purkayastha, S. (2023) · The British Journal of Radiology · doi:10.1259/bjr.20230023 · Cited by 277
Pekosz, A., Parvu, V., Li, M., Andrews, J. C., Manabe, Y. C., Kodsi, S., Gary, D. S., Roger-Dalbert, C., Leitch, J., & Cooper, C. K. (2021) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa1706 · Cited by 276
Vollgraff Heidweiller‐Schreurs, C. A., De Boer, M. A., Heymans, M. W., Schoonmade, L. J., Bossuyt, P. M. M., Mol, B. W. J., De Groot, C. J. M., & Bax, C. J. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.18809 · Cited by 255
Self-citationThoracic imaging tests for the diagnosis of COVID-19
Islam, N., Ebrahimzadeh, S., Salameh, J.-P., Kazi, S., Fabiano, N., Treanor, L., Absi, M., Hallgrimson, Z., Leeflang, M. M., Hooft, L., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013639.pub4 · Cited by 196
Self-citationTomita, N., Abdollahi, B., Wei, J., Ren, B., Suriawinata, A., & Hassanpour, S. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.14645 · Cited by 187
Sorin, V., Yagil, Y., Yosepovich, A., Shalmon, A., Gotlieb, M., Neiman, O. H., & Sklair-Levy, M. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.19355 · Cited by 181
“Results were reported according to Standards for Reporting Diagnostic Accuracy Studies (STARD) guidelines [27, 28].”
Method“Interchangeability” of PD-L1 immunohistochemistry assays: a meta-analysis of diagnostic accuracy
Torlakovic, E., Lim, H. J., Adam, J., Barnes, P., Bigras, G., Chan, A. W. H., Cheung, C. C., Chung, J.-H., Couture, C., Fiset, P. O., et al. (2020) · Modern Pathology · doi:10.1038/s41379-019-0327-4 · Cited by 178
Han, K., Song, K., & Choi, B. W. (2016) · Korean Journal of Radiology · doi:10.3348/kjr.2016.17.3.339 · Cited by 162
D'Souza, N., Georgiou Delisle, T., Chen, M., Benton, S., & Abulafi, M. (2021) · Gut · doi:10.1136/gutjnl-2020-321956 · Cited by 161
Deep learning-aided decision support for diagnosis of skin disease across skin tones
Groh, M., Badri, O., Daneshjou, R., Koochek, A., Harris, C., Soenksen, L. R., Doraiswamy, P. M., & Picard, R. (2024) · Nature Medicine · doi:10.1038/s41591-023-02728-3 · Cited by 160
Drukker, K., Chen, W., Gichoya, J. W., Gruszauskas, N. P., Kalpathy-Cramer, J., Koyejo, S., Myers, K. J., Sá, R. C., Sahiner, B., Whitney, H. M., et al. (2023) · Journal of Medical Imaging · doi:10.1117/1.jmi.10.6.061104 · Cited by 149
Diagnosis of aphasia in stroke populations: A systematic review of language tests
Rohde, A., Worrall, L., Godecke, E., O’Halloran, R., Farrell, A., & Massey, M. (2018) · PLOS ONE · doi:10.1371/journal.pone.0194143 · Cited by 113
Ethical considerations for artificial intelligence: an overview of the current radiology landscape.
Department of Radiology and Nuclear Medicine, U. H. B., & Akinci D'Antonoli, T. (2020) · Diagnostic and Interventional Radiology · doi:10.5152/dir.2020.19279 · Cited by 80
Fehr, J., Konigorski, S., Olivier, S., Gunda, R., Surujdeen, A., Gareta, D., Smit, T., Baisley, K., Moodley, S., Moosa, Y., et al. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00471-y · Cited by 74
Prospective Development and Validation of the Computerized Adaptive Screen for Suicidal Youth
King, C. A., Brent, D., Grupp-Phelan, J., Casper, T. C., Dean, J. M., Chernick, L. S., Fein, J. A., Mahabee-Gittens, E. M., Patel, S. J., Mistry, R. D., et al. (2021) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2020.4576 · Cited by 71
Muñoz‐López, C., Ramírez‐Cornejo, C., Marchetti, M. A., Han, S. S., Del Barrio‐Díaz, P., Jaque, A., Uribe, P., Majerson, D., Curi, M., Del Puerto, C., et al. (2021) · Journal of the European Academy of Dermatology and Venereology · doi:10.1111/jdv.16979 · Cited by 70
AI Reporting Guidelines: How to Select the Best One for Your Research
Klontzas, M. E., Gatti, A. A., Tejani, A. S., & Kahn, C. E. (2023) · Radiology: Artificial Intelligence · doi:10.1148/ryai.230055 · Cited by 66
Outcome‐based comparison of SMFM and ISUOG definitions of fetal growth restriction
Roeckner, J. T., Pressman, K., Odibo, L., Duncan, J. R., & Odibo, A. O. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23638 · Cited by 60
Use of Artificial Intelligence as an Innovative Method for Liver Graft Macrosteatosis Assessment
Cesaretti, M., Brustia, R., Goumard, C., Cauchy, F., Poté, N., Dondero, F., Paugam‐Burtz, C., Durand, F., Paradis, V., Diaspro, A., et al. (2020) · Liver Transplantation · doi:10.1002/lt.25801 · Cited by 50
Harmonization initiatives in the generation, reporting and application of biological variation data
Aarsand, A. K., Røraas, T., Bartlett, W. A., Coşkun, A., Carobene, A., Fernandez-Calle, P., Jonker, N., Díaz-Garzón, J., Braga, F., & Sandberg, S. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0058 · Cited by 46
Evaluating GPT-4-based ChatGPT’s Clinical Potential on the NEJM Quiz
Ueda, D., Walston, S. L., Matsumoto, T., Deguchi, R., Tatekawa, H., & Miki, Y. (2023) · doi:10.1101/2023.05.04.23289493 · Cited by 45
Weikert, T., Francone, M., Abbara, S., Baessler, B., Choi, B. W., Gutberlet, M., Hecht, E. M., Loewe, C., Mousseaux, E., Natale, L., et al. (2021) · European Radiology · doi:10.1007/s00330-020-07417-0 · Cited by 34
Performance of AI to exclude normal chest radiographs to reduce radiologists' Workload
Schalekamp, S., van Leeuwen, K., Calli, E., Murphy, K., Rutten, M., Geurts, B., Peters-Bax, L., van Ginneken, B., & Prokop, M. (2024) · European Radiology · doi:10.1007/s00330-024-10794-5 · Cited by 28
Andrés-Blanco, A. M., Álvarez, D., Crespo, A., Arroyo, C. A., Cerezo-Hernández, A., Gutiérrez-Tobal, G. C., Hornero, R., & del Campo, F. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188094 · Cited by 28
Sivanesan, U., Wu, K., McInnes, M. D. F., Dhindsa, K., Salehi, F., & van der Pol, C. B. (2023) · Canadian Association of Radiologists Journal · doi:10.1177/08465371221134056 · Cited by 19
Vollgraff Heidweiller-Schreurs, C. A., Korevaar, D. A., Mol, B. W. J., Bax, C. J., de Groot, C. J. M., de Boer, M. A., & Bossuyt, P. M. M. (2019) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2019.07.016 · Cited by 12
Self-citationUnderstanding ‘error’ in the forensic sciences: A primer
Martire, K. A., Chin, J. M., Davis, C., Edmond, G., Growns, B., Gorski, S., Kemp, R. I., Lee, Z., Verdon, C. M., Jansen, G., et al. (2024) · Forensic Science International: Synergy · doi:10.1016/j.fsisyn.2024.100470 · Cited by 9
Lovero, K. L., Stockton, M. A., Greene, M. C., Basaraba, C., Khan, S., Mabunda, D., Mandlate, F., Gouveia, L., Fumo, W., Wall, M. M., et al. (2024) · Medical Research Archives · doi:10.18103/mra.v12i8.5294 · Cited by 4
Metadata
- Authors
- Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., Kressel, H. Y., Rifai, N., Golub, R. M., Altman, D. G., Hooft, L., Korevaar, D. A., Cohen, J. F., & For the STARD Group
- Venue
- Radiology
- Published
- 2015-12
- Volume
- 277
- Issue
- 3
- Pages
- 826-832
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1830758076
- Cited by
- 1,337
- References
- 23
- FWCI
- 75.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.