Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

MR Fingerprinting for Rapid Quantitative Abdominal Imaging

Open access
Chen, Yong, Jiang, Yun, Pahwa, Shivani, Ma, Dan, Lu, Lan, Twieg, Michael D., Wright, Katherine L., Seiberlich, Nicole, Griswold, Mark A., Gulani, Vikas·2016·Radiology

Abstract

PURPOSE: To develop a magnetic resonance (MR) "fingerprinting" technique for quantitative abdominal imaging. MATERIALS AND METHODS: This HIPAA-compliant study had institutional review board approval, and informed consent was obtained from all subjects. To achieve accurate quantification in the presence of marked B0 and B1 field inhomogeneities, the MR fingerprinting framework was extended by using a two-dimensional fast imaging with steady-state free precession, or FISP, acquisition and a Bloch-Siegert B1 mapping method. The accuracy of the proposed technique was validated by using agarose phantoms. Quantitative measurements were performed in eight asymptomatic subjects and in six patients with 20 focal liver lesions. A two-tailed Student t test was used to compare the T1 and T2 results in metastatic adenocarcinoma with those in surrounding liver parenchyma and healthy subjects. RESULTS: Phantom experiments showed good agreement with standard methods in T1 and T2 after B1 correction. In vivo studies demonstrated that quantitative T1, T2, and B1 maps can be acquired within a breath hold of approximately 19 seconds. T1 and T2 measurements were compatible with those in the literature. Representative values included the following: liver, 745 msec ± 65 (standard deviation) and 31 msec ± 6; renal medulla, 1702 msec ± 205 and 60 msec ± 21; renal cortex, 1314 msec ± 77 and 47 msec ± 10; spleen, 1232 msec ± 92 and 60 msec ± 19; skeletal muscle, 1100 msec ± 59 and 44 msec ± 9; and fat, 253 msec ± 42 and 77 msec ± 16, respectively. T1 and T2 in metastatic adenocarcinoma were 1673 msec ± 331 and 43 msec ± 13, respectively, significantly different from surrounding liver parenchyma relaxation times of 840 msec ± 113 and 28 msec ± 3 (P < .0001 and P < .01) and those in hepatic parenchyma in healthy volunteers (745 msec ± 65 and 31 msec ± 6, P < .0001 and P = .021, respectively). CONCLUSION: A rapid technique for quantitative abdominal imaging was developed that allows simultaneous quantification of multiple tissue properties within one 19-second breath hold, with measurements comparable to those in published literature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2016152037

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 211

Metadata

Authors
Chen, Y., Jiang, Y., Pahwa, S., Ma, D., Lu, L., Twieg, M. D., Wright, K. L., Seiberlich, N., Griswold, M. A., & Gulani, V.
Venue
Radiology
Published
2016-04
Volume
279
Issue
1
Pages
278-286
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2263221359
Cited by
211
References
4
FWCI
18.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MR Fingerprinting for Rapid Quantitative Abdominal Imaging. https://app.cochat.ai/papers/10.1148/radiol.2016152037
The paper
Chen, Y., Jiang, Y., Pahwa, S., Ma, D., Lu, L., Twieg, M. D., Wright, K. L., Seiberlich, N., Griswold, M. A., & Gulani, V. (2016). MR Fingerprinting for Rapid Quantitative Abdominal Imaging. Radiology. https://doi.org/10.1148/radiol.2016152037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.