The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Photon-counting CT: Technical Principles and Clinical Prospects
Open accessAbstract
Photon-counting CT is an emerging technology with the potential to dramatically change clinical CT. Photon-counting CT uses new energy-resolving x-ray detectors, with mechanisms that differ substantially from those of conventional energy-integrating detectors. Photon-counting CT detectors count the number of incoming photons and measure photon energy. This technique results in higher contrast-to-noise ratio, improved spatial resolution, and optimized spectral imaging. Photon-counting CT can reduce radiation exposure, reconstruct images at a higher resolution, correct beam-hardening artifacts, optimize the use of contrast agents, and create opportunities for quantitative imaging relative to current CT technology. In this review, the authors will explain the technical principles of photon-counting CT in nonmathematical terms for radiologists and clinicians. Following a general overview of the current status of photon-counting CT, they will explain potential clinical applications of this technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Vision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 948
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
Cardiac Computed Tomography Writing Group, Taylor, A. J., Cerqueira, M., Hodgson, J. M., Mark, D., Min, J., O'Gara, P., & Rubin, G. D. (2010) · Circulation · doi:10.1161/cir.0b013e3181fcae66 · Cited by 647
K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
Roessl, E., & Proksa, R. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/020 · Cited by 558
Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
Cormode, D. P., Roessl, E., Thran, A., Skajaa, T., Gordon, R. E., Schlomka, J.-P., Fuster, V., Fisher, E. A., Mulder, W. J. M., Proksa, R., et al. (2010) · Radiology · doi:10.1148/radiol.10092473 · Cited by 479
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Self-citationVirtual monochromatic imaging in dual‐source dual‐energy CT: Radiation dose and image quality
Yu, L., Christner, J. A., Leng, S., Wang, J., Fletcher, J. G., & McCollough, C. H. (2011) · Medical Physics · doi:10.1118/1.3658568 · Cited by 343
Evaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography
Boas, F. E., & Fleischmann, D. (2011) · Radiology · doi:10.1148/radiol.11101782 · Cited by 303
Self-citationGutjahr, R., Halaweish, A. F., Yu, Z., Leng, S., Yu, L., Li, Z., Jorgensen, S. M., Ritman, E. L., Kappler, S., & McCollough, C. H. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000251 · Cited by 282
Pache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., et al. (2010) · Radiology · doi:10.1148/radiol.10091230 · Cited by 281
Nanotechnology in Medical Imaging: Probe Design and Applications
Cormode, D. P., Skajaa, T., Fayad, Z. A., & Mulder, W. J. M. (2009) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.108.165506 · Cited by 275
SNR and DQE analysis of broad spectrum X-ray imaging
Tapiovaara, M. J., & Wagner, R. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/6/002 · Cited by 228
Yeh, B. M., FitzGerald, P. F., Edic, P. M., Lambert, J. W., Colborn, R. E., Marino, M. E., Evans, P. M., Roberts, J. C., Wang, Z. J., Wong, M. J., et al. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.09.001 · Cited by 219
Symons, R., Krauss, B., Sahbaee, P., Cork, T. E., Lakshmanan, M. N., Bluemke, D. A., & Pourmorteza, A. (2017) · Medical Physics · doi:10.1002/mp.12301 · Cited by 217
Self-citationAbdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience
Pourmorteza, A., Symons, R., Sandfort, V., Mallek, M., Fuld, M. K., Henderson, G., Jones, E. C., Malayeri, A. A., Folio, L. R., & Bluemke, D. A. (2016) · Radiology · doi:10.1148/radiol.2016152601 · Cited by 207
Self-citationSeeing Within: Molecular Imaging of the Cardiovascular System
Jaffer, F. A., & Weissleder, R. (2004) · Circulation Research · doi:10.1161/01.res.0000119321.18573.5a · Cited by 196
Symons, R., Reich, D. S., Bagheri, M., Cork, T. E., Krauss, B., Ulzheimer, S., Kappler, S., Bluemke, D. A., & Pourmorteza, A. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000418 · Cited by 191
Self-citationFeasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans
Symons, R., Pourmorteza, A., Sandfort, V., Ahlman, M. A., Cropper, T., Mallek, M., Kappler, S., Ulzheimer, S., Mahesh, M., Jones, E. C., et al. (2017) · Radiology · doi:10.1148/radiol.2017162587 · Cited by 188
Self-citationDual- and multi-energy CT: approach to functional imaging
Fornaro, J., Leschka, S., Hibbeln, D., Butler, A., Anderson, N., Pache, G., Scheffel, H., Wildermuth, S., Alkadhi, H., & Stolzmann, P. (2011) · Insights into Imaging · doi:10.1007/s13244-010-0057-0 · Cited by 184
Cormode, D. P., Si-Mohamed, S. A., Bar-Ness, D., Sigovan, M., Naha, P. C., Balegamire, J., Lavenne, F., Coulon, P., Roessl, E., Bartels, M.-B., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-04659-9 · Cited by 163
Guggenberger, R., Gnannt, R., Hodler, J., Krauss, B., Wanner, G. A., Csuka, E., Payne, B., Frauenfelder, T., Andreisek, G., & Alkadhi, H. (2012) · Radiology · doi:10.1148/radiol.12112217 · Cited by 159
Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging
Kooiman, J., Pasha, S. M., Zondag, W., Sijpkens, Y. W. J., van der Molen, A. J., Huisman, M. V., & Dekkers, O. M. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.11.020 · Cited by 157
Spectral Photon-counting CT: Initial Experience with Dual–Contrast Agent K-Edge Colonography
Muenzel, D., Bar-Ness, D., Roessl, E., Blevis, I. M., Bartels, M., Fingerle, A. A., Ruschke, S., Coulon, P., Daerr, H., Kopp, F. K., et al. (2016) · Radiology · doi:10.1148/radiol.2016160890 · Cited by 143
Si-Mohamed, S. A., Cormode, D. P., Bar-Ness, D., Sigovan, M., Naha, P. C., Langlois, J., Chalabreysse, L., Coulon, P., Blevis, I. M., Roessl, E., et al. (2017) · Nanoscale · doi:10.1039/c7nr01153a · Cited by 137
Si-Mohamed, S. A., Bar-Ness, D., Sigovan, M., Cormode, D. P., Coulon, P., Coche, E., Vlassenbroek, A., Normand, G., Boussel, L., & Douek, P. (2017) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2017.04.014 · Cited by 128
Dual-Energy Spectral CT: Various Clinical Vascular Applications
Machida, H., Tanaka, I., Fukui, R., Shen, Y., Ishikawa, T., Tate, E., & Ueno, E. (2016) · Radiographics · doi:10.1148/rg.2016150185 · Cited by 121
Low-dose lung cancer screening with photon-counting CT: a feasibility study
Symons, R., Cork, T. E., Sahbaee, P., Fuld, M. K., Kappler, S. G., Folio, L. R., Bluemke, D. A., & Pourmorteza, A. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/62/1/202 · Cited by 120
Self-citationSensitivity of Photon-Counting Based ${\rm K}$-Edge Imaging in X-ray Computed Tomography
Roessl, E., Brendel, B., Engel, K.-J., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2142188 · Cited by 118
Xu, C., Danielsson, M. E., & Bornefalk, H. (2011) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2011.2122267 · Cited by 107
Reddy, T., McLaughlin, P. D., Mallinson, P. I., Reagan, A. C., Munk, P. L., Nicolaou, S., & Ouellette, H. A. (2014) · Emergency Radiology · doi:10.1007/s10140-014-1249-6 · Cited by 104
Barreto, M., Schoenhagen, P., Nair, A., Amatangelo, S., Milite, M., Obuchowski, N. A., Lieber, M. L., & Halliburton, S. S. (2008) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2008.05.146 · Cited by 102
Kellock, T. T., Nicolaou, S., Kim, S. S. Y., Al-Busaidi, S., Louis, L. J., O’Connell, T. W., Ouellette, H. A., & McLaughlin, P. D. (2017) · Radiology · doi:10.1148/radiol.2017161063 · Cited by 97
Toward quantifying the composition of soft tissues by spectral CT with Medipix3
Ronaldson, J. P., Zainon, R., Scott, N. J. A., Gieseg, S. P., Butler, A. P. H., Butler, P. H., & ANDERSON, N. G. (2012) · Medical Physics · doi:10.1118/1.4760773 · Cited by 74
To bin or not to bin? The effect of CT system limiting resolution on noise and detectability
Baek, J., Pineda, A. R., & Pelc, N. J. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/5/1433 · Cited by 68
Self-citationDong, J., Wang, X., Jiang, X.-X., Gao, L., Li, F., Qiu, J., Xu, Y., & Wang, H. (2013) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e31828f5020 · Cited by 36
Müllner, M., Schlattl, H., Hoeschen, C., & Dietrich, O. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.06.004 · Cited by 33
McMillan, K. L., Bostani, M., Cagnon, C. H., Yu, L., Leng, S., McCollough, C. H., & McNitt‐Gray, M. F. (2017) · Medical Physics · doi:10.1002/mp.12314 · Cited by 33
Minimising medically unwarranted computed tomography scans
Brenner, D. J. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.06.004 · Cited by 30
Signal to noise ratio of energy selective x‐ray photon counting systems with pileup
Alvarez, R. E. (2014) · Medical Physics · doi:10.1118/1.4898102 · Cited by 12
Cited by
Willemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Self-citationFlohr, T., Petersilka, M., Henning, A., Ulzheimer, S., Ferda, J., & Schmidt, B. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.030 · Cited by 581
Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects
Koetzier, L. R., Mastrodicasa, D., Szczykutowicz, T. P., van der Werf, N. R., Wang, A. S., Sandfort, V., van der Molen, A. J., Fleischmann, D., & Willemink, M. J. (2023) · Radiology · doi:10.1148/radiol.221257 · Cited by 427
Self-citationHe, Y., Hadar, I., & Kanatzidis, M. G. (2022) · Nature Photonics · doi:10.1038/s41566-021-00909-5 · Cited by 301
Multiscale X-ray tomography of cementitious materials: A review
Brisard, S., Serdar, M., & Monteiro, P. J. M. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2019.105824 · Cited by 260
Metadata
- Authors
- Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D.
- Venue
- Radiology
- Published
- 2018-11
- Volume
- 289
- Issue
- 2
- Pages
- 293-312
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2889741596
- Cited by
- 1,326
- References
- 42
- FWCI
- 19.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.