CoChat

Contrast-enhanced Mammography versus Contrast-enhanced Breast MRI: A Systematic Review and Meta-Analysis

Pötsch, Nina, Vatteroni, Giulia, Clauser, Paola, Helbich, Thomas H., Baltzer, Pascal A. T. · 2022 · Radiology
Cited by 162

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Background Contrast-enhanced mammography (CEM) is a more accessible alternative to contrast-enhanced MRI (CE-MRI) in breast imaging, but a summary comparison of published studies is lacking. Purpose To directly compare the performance of CEM and CE-MRI regarding sensitivity, specificity, and negative predictive value in detecting breast cancer, involving all publicly available studies in the English language. Materials and Methods Two readers extracted characteristics of studies investigating the comparative diagnostic performance of CEM and CE-MRI in detecting breast cancer. Studies published until April 2021 were eligible. Sensitivity, specificity, negative predictive value, and positive and negative likelihood ratios were calculated using bivariate random effects models. A Fagan nomogram was used to identify the maximum pretest probability at which posttest probabilities of a negative CEM or CE-MRI examination were in line with the 2% malignancy rate benchmark for downgrading a Breast Imaging Reporting and Data System (BI-RADS) category 4 to a BI-RADS category 3 result. I 2 statistics, Deeks funnel plot asymmetry test for publication bias, and meta-regression were used. Results Seven studies investigating 1137 lesions (654 malignant, 483 benign) with an average cancer prevalence of 65.3% (range: 47.3%–82.2%) were included. No publication bias was found (P = .57). While the positive likelihood ratio was equal at a value of 3.1 for CE-MRI and 3.6 for CEM, the negative likelihood ratio of CE-MRI (0.04) was lower than that with CEM (0.12). CE-MRI had higher sensitivity for breast cancer than CEM (97% [95% CI: 86, 99] vs 91% [95% CI: 77, 97], respectively; P < .001) but lower specificity (69% [95% CI: 46, 85] vs 74% [95% CI: 52, 89]; P = .09). A Fagan nomogram demonstrated that the maximum pretest probability at which both tests could rule out breast cancer was 33% for CE-MRI and 14% for CEM. Furthermore, iodine concentration was positively associated with CEM sensitivity and negatively associated with its specificity (P = .04 and P < .001, respectively). Conclusion Contrast-enhanced MRI had superior sensitivity and negative likelihood ratios with higher pretest probabilities to rule out malignancy compared with contrast-enhanced mammography. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Mann and Veldhuis in this issue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.212530

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Pötsch, N., Vatteroni, G., Clauser, P., Helbich, T. H., & Baltzer, P. A. T.
Venue
Radiology
Published
2022-10
Volume
305
Issue
1
Pages
94-103
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W4281855545
Cited by
162
References
20
FWCI
7.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.